1 Introduction

Since 2000, a compelling body of research has been dedicated to numerically evidence the advantages and efficiency of using CO2, alternative to water, as heat transmission fluid for geothermal energy recovery from enhanced geothermal systems (EGS) where the permeability of the underground source is enhanced by hydrofracturing (Brown 2000; Fouillac et al. 2004; Pruess and Azaroual 2006; Atrens et al. 2008; Xu et al. 2015b). It has been reasoned that CO2 has lower viscosity than water and has a thermosyphon effect, which reduces the parasitic power consumption of the working-fluid recirculation system (Buscheck et al. 2012a). Additionally, under favourable conditions for storage, injected CO2 is entrapped in the systems, which helps the economy of the operations by reducing carbon footprint, and as a long-term objective, helps reduce CO2 emission to atmosphere. Nevertheless, if CO2 is being utilised as a transmission fluid that requires recirculation and early breakthrough, a smaller well spacing between injectors/producers (such as doublets) should be considered. Therefore, geological carbon storage is an ancillary objective of such operations, whereas primarily CO2 will be used as transmission fluid (Brown 2000; Pruess 2006; Xu et al. 2008; Buscheck et al. 2012a, b).

Alternatively, CO2 can be used, in farther well spacing, for geothermal reservoir systems such as hydrothermal reservoirs and hot sedimentary aquifers with naturally sufficiently porous and permeable formations overlain by caprock. The goal of injecting CO2 is then to provide the necessary pressure of fluid production and to displace native formation fluid (e.g. brine or hydrocarbons). In this so-called CO2-plume geothermal (CPG) approach (Randolph and Saar 2011a, b; Adams et al. 2014; Ganjdanesh et al. 2015) the working fluid is not necessarily CO2 only, and contrary to the first application, a key objective is to provide simultaneous CO2-injection-induced pressure relief by producing hot brine with consumptive beneficial uses (Buscheck et al. 2012b). The purpose also shifts to maximise brine production (i.e. energy and heat) and minimise CO2 production to increase CO2 storage capacity and efficiency. If the reservoir is overpressurised by CO2 injection, various methodologies that are designed to manage, avoid and minimise pressure build-up in geological-CO2-storage-only operations [as reviewed comprehensively in Birkholzer et al. (2015)] can be adapted for geothermal heat recovery. Consequently between the two approaches (EGS where CO2 is used as transmission fluid and CPG where CO2 is used for storage and brine production), a same metric, i.e. amount of produced CO2, is favourable in opposite extremes. This metric will be directly dependent on the well spacing, number and pattern administered in the operation.

Lack of production history from non-hydrocarbon aquifer systems implies large uncertainty which leads to complexities and added level of required caution in operation planning and decision making. Therefore, the boundary conditions have also significant impact on the performance of CO2 injection into saline aquifers. From hydrodynamic point of view, it is extremely important to properly prescribe hydrogeological boundary conditions and quantify the flow and pressure support (or lack of it) based on formation geological and seismic data. The boundary conditions will represent (a) the lateral extent of the storage formations may prove to be compartmentalised or open and (b) will determine the reservoir-scale effective conductivity of the overlying low-permeable caprock. Aquifer flux from lateral boundaries of extensively large aquifers is unhindered; however, disruptive or faults-induced compartmentalised formations may demonstrate restricted-flow or no-flow barrier-like boundary conditions (Holloway 2009). Examples of compartmentalised geothermal reservoirs are Torre Alfina field in Italy (Vignaroli et al. 2013) and Rotokawa geothermal field in New Zealand (McNamara et al. 2016).

From geothermal point of view, boundaries contribute to conduction as the prevalent mechanism of heat transfer for enhanced geothermal systems, whereas for hydrothermal aquifers, in addition to conduction, convection flow also contributes to the mass/heat transport phenomena (Franco and Vaccaro 2014). Background heat flow conduction is usually in order of 65–80 mW/m2 (DiPippo 2012). To represent conductive basal heat flow, often a hot plate boundary condition is assumed; however, this technique provides an infinite source of hot water with spurious quasi steady state. DiPippo (2012) argues that it is better to extend the model vertically for 6–8 km so that the heat flow is realistically physically included; however, this comes with prohibitive computational overhead. An alternative approach is to assume additional pore volume attached to the boundaries of geothermal reservoir. Consequently, representing the heat conduction from base is challenging and requires extra care in modelling.

For combined thermo-hydrologic boundary conditions, a survey of recent literature publications shows different treatments in numerical models:

  • Vogt et al. (2010) assumed the basal heat flow uncertain in a geothermal reservoir, in The Hague, Netherlands, to vary in the range of 63 ± 3 mW/m2.

  • Randolph and Saar (2011a) used no-flow no-heat-flux boundary conditions at top and sides, and analytical heat conduction and no fluid flow for base for a theoretical CPG and EGS.

  • Tutolo et al. (2015) for a 200 bar, 100 °C calcite and dolomite carbonate reservoirs prescribed the upper and lower domain boundaries with no-flow boundary conditions and prescribed the sides with hydrostatically equilibrated aquifers to allow heat and fluid flow.

  • Saeid et al. (2015) prescribed heat flux and flow rate at top for a prototypical model of deep low-enthalpy hydrothermal systems.

  • Xu et al. (2015a) prescribed no heat and fluid flow on the lateral boundaries of a theoretical EGS system.

Above-mentioned research works demonstrate the importance, uncertainty and varying representability in thermo-hydrologic boundary conditions. Amongst the reviewed articles, no work has systematically examined the effect of boundary conditions on the CO2–geothermal system performance measures. To elucidate the effects of boundary conditions specifically for an integrated carbon sequestration–geothermal heat recovery from sedimentary aquifers with sufficient permeability and porosity (CPG), I define and conduct an extensive series of simulations. I also assess effects of varying well numbers by choosing three patterns of well spacing. Our objectives are to quantify the boundary conditions- and well spacing-induced change in key performance indicators of the operation, namely the changes in CO2 storage efficiency, net accumulated CO2 in the system, geothermal heat recovery and salt precipitation. In order to be able to isolate the effects of boundary condition and well spacing on the outputs, I impose restricting and unrealistic assumptions such as homogeneity and isotropicity of the geothermal model, simplicity of boundary water influx and outflux and confinement of the aquifer from top and base with respect to heat and fluid flows.

1.1 Outline

The paper is structured as following. In Sect. 2, the simulator chosen for studies and the synthetic model of hot sedimentary aquifer under study are described. In Sect. 3, the simulation runs and the performance metrics are defined. In Sect. 4, results will be presented, which is followed by Sect. 5 for conclusions and future research considerations.

2 Simulator and Model of Geothermal Reservoir

I use Schlumberger ECLIPSE E300 simulator, capable of conducting compositional modelling of CO2–geothermal heat recovery operations for geothermal aquifers that contain NaCl and CaCl2. The simulator solves the coupled mass continuity and energy equations, using Darcy’s law to describe multiphase flow. Mutual solubilities of CO2 and H2O are calculated by phase partitioning model (Spycher and Pruess 2005, 2010) to match the experimental data in the range of 12–250 °C and up to 600 bars. Alongside the following first three reactions for speciation of water and aqueous CO2, the following last two equilibrium reactions are used to determine NaCl and CaCl2 mol present in the aqueous phase and the solid phase:

  • $$ {\text{H}}_{2} {\text{O}} \rightleftharpoons {\text{H}}^{ + } + {\text{OH}}^{ - } $$
  • $$ {\text{CO}}_{2} \left( {\text{aq}} \right) + {\text{H}}_{2} {\text{O}} \rightleftharpoons {\text{HCO}}_{3}^{ - } + {\text{H}}^{ + } $$
  • $$ {\text{HCO}}_{3}^{ - } \rightleftharpoons {\text{CO}}_{3}^{2 - } + {\text{H}}^{ + } $$
  • $$ {\text{CaCl}}_{2} \left( {\text{solid}} \right) \rightleftharpoons {\text{Ca}}^{2 + } \left( {\text{aq}} \right) + 2{\text{Cl}}^{\text{ - }} \left( {\text{aq}} \right) $$
  • $$ {\text{NaCl}}\left( {\text{solid}} \right) \rightleftharpoons {\text{Na}}^{ + } \left( {\text{aq}} \right) + {\text{Cl}}^{\text{ - }} \left( {\text{aq}} \right) $$

In “Appendix A”, a brief overview of the fluid properties in presence of salt and the main governing equations are provided. I use a simple horizontal, rectangular (3 km × 3 km × 100 m), homogenous, isotropic model of a hot sedimentary aquifer, as shown in Fig. 1. The constant values for the rock and fluid parameters are reported in Table 1. The top of the model is 2000 m deep. Pressure of 200 bar and temperature of 80 °C at 2000 m are imposed for initialisation. As such, the theoretical geothermal reservoir in this work is classified as low-enthalpy or low-temperature systems and is tried to replicate the depth, initial pressure and temperature of fluvial Delft Sandstone Member with 3 k/100 m temperature gradient (Bonté et al. 2012; Salimi and Wolf 2012; Crooijmans et al. 2016). Also, for high-enthalpy reservoirs (i.e. T > 200 °C), the flash calculations in ECLIPSE E300 fail. Therefore, the justification to choose a low-enthalpy reservoir is also based on the limitation of the simulator.

Fig. 1
figure 1

Schematic of hot sedimentary system with open and close boundary conditions

Table 1 Several rock and fluid properties of the geothermal system

The pressure gradient in the system is ignored, and the model is initialised with uniform 80 °C. An initial aqueous ion concentration analysis shows speciation of 91.0 g/L Na+, 22.6 g/L Ca2+ and Cl g/L concentration. For a water density of 936.2 kg/m3 at reservoir condition, the analysis corresponds to overall molar composition of 0.92 H2O, 0.07 NaCl and 0.01 CaCl2, or ~ 24% salt mass fraction in brine, and equivalent salt molality of 4.83 g mol/kg across the geothermal system.Footnote 1

In this study, the choices of boundary conditions are limited to

  • Hydrologically and thermally fully open from all lateral sides (free heat and fluid flow), fully close and sealed from top and base (no convective a conductive heat and no fluid flow)

  • Hydrologically and thermally fully close from all lateral and horizontal sides.

For open boundary condition I assume the geothermal system is in unconfined mass and heat communication with the surrounding side aquifers through additional pore volume. To replicate this situation, I use pore volume multipliers on the boundary gridblocks to enlarge their pore volume by a factor of 1000. This number is arbitrarily chosen to implicate an infinite acting aquifer; nevertheless, smaller numbers could have been chosen with the same effect. For the case of close boundary condition, I assume the reservoir is sealed from the four sides and there is no heat and mass communication between the geothermal system and surrounding aquifers. For the illustration purposes, the top and bottom of the geothermal system are assumed fully bounded by low-permeable strata, and neither overburden nor underburden conductive heat transfer occurs across these faces.

3 Simulation Runs and Performance Metrics

3.1 Simulation Runs

Substantial attention has been paid to well spacing and placement optimisation for maximising CO2 storage and capacity (Cameron and Durlofsky 2012; Vogt 2013; Cihan et al. 2015; Chen et al. 2015; Babaei et al. 2015). In addition to well spacing, there are numerous operation parameters to be treated as state variables of optimisation, such as number of wells, angle of preformation and inclination, and injection scheduling. To facilitate conclusiveness on effects of well spacing, number and pattern, I simplify the problem by assuming three regular layouts of the well placement in the reservoir as shown in Fig. 2. The same layouts have been used to study the CO2 storage efficiency in carbon sequestration in saline aquifers by Heath et al. (2014). Here, I adapt these layouts to calculate heat recovery as well as CO2 storage efficiency. These layouts are referred to as 3 × 3, 5 × 5 and 7 × 7 well patterns that include 5, 13 and 25 injection wells, and 4, 12 and 24 production wells, respectively. The dotted grey lines in these patterns represent inverted five-spot well placement. For all layouts I use 60 × 60 × 10 = 36,000 gridblocks for simulation. Therefore, I include the effects of gravity override in the simulations.

Fig. 2
figure 2

From (Heath et al. 2014): map view of well layouts in the geothermal resource model under study. From left to right, the well layouts are 3 × 3, 5 × 5 and 7 × 7. Triangles are CO2 injectors, whereas circles are brine extractors. The dotted grey lines highlight inverted five-spot well placement

Pure CO2 is injected at 20 °C. The injection from the injectors is conducted by dividing a specified total injection rate of CO2, \( Q_{\text{inj}} \), between the available injection wells. The perforations go through all 10 reservoir layers. The injection mode is constant injection rate with very large allowable bottomhole pressure of 500 bar. I use 3 total volumetric injection rates of 1.5 × 106, 3 × 106 and 4.5 × 106 sm3/day, where sm3 stands for standard-condition cubic metre. Considering a standard-condition CO2 density of 1.98 kg/sm3, the mass injection rates are 34.375 kg/s (~ 1.08 million tonne per annum), 68.750 kg/s (~ 2.17 million tonne per annum) and 103.125 kg/s (~ 3.25 million tonne per annum). The injection period is 20 years. The production of fluid from extraction wells is conducted at constant bottomhole pressures of Pbh of 200, 180 and 160 bar. The first pressure will provide a case of constrained extraction where the reservoir pressure is maintained close to its initial level. In the second and third runs, the constraint is relaxed so that fluid is produced more easily from the reservoir. It is noteworthy that, the results of this work will be different if other well control modes were selected and the conclusions of this work are only valid for the prescribed control modes.

In total, I perform 54 simulation runs as summarised in Table 2. The simulation models contain 36,000 gridblocks of size 50 m × 50 m × 10 m. The simulations are conducted using Schlumberger’s ECLIPSE E300 compositional simulator (Schlumberger 2014b).

Table 2 Fifty-four simulation runs defined for the multiparametric analysis of this study

3.2 Performance Metrics

3.2.1 CO2 Injection Metrics

From the numerical simulation results, one can obtain the mass of CO2 accumulated in the global domain (mass-in-place), expressed in million tonnes of CO2 (Mt), as:

$$ {\text{MIP}}_{{{\text{CO}}_{2} }}^{t} = M_{\text{inj}}^{t} - M_{\text{prd}}^{t} + {\text{MIIP}} $$
(1)

where \( M_{\text{inj}}^{t} \), \( M_{\text{prd}}^{t} \) and \( {\text{MIIP}} \) (Mt) are, respectively, the cumulative mass of injected CO2, the cumulative mass of produced CO2, and the mass initially in place of CO2 in the global domain of the geothermal system, all at time t. In this formulation, \( {\text{MIP}}_{{{\text{CO}}_{2} }}^{t} \) refers to the accumulated mass of CO2 in the subsurface system in any state, i.e. either free CO2 in its own phase (\( {\text{MIP}}_{\text{gas}}^{t} \)) or dissolved in aqueous phase. (\( {\text{MIP}}_{\text{dis}}^{t} \)). For an optimal storage of CO2, the dissolved amount of CO2 must be enhanced. The net mass of CO2 that is left in the geothermal system at time t is:

$$ M_{\text{net}}^{t} = M_{\text{inj}}^{t} - M_{\text{prd}}^{t} $$
(2)

I define a dimensionless CO2 injection efficiency factor as:

$$ e_{\text{inj}}^{t} = \frac{{M_{\text{inj}}^{t} - M_{\text{prd}}^{t} }}{{M_{\text{inj}}^{t} }} $$
(3)

that points to the fraction of injected CO2 that is in place at time t.

In the absence of numerical simulation, the researchers have defined a “volumetric” storage efficiency factor, \( e_{{{\text{CO}}_{2} }} \), as the fraction of the total pore volume occupied with the injected free-phase CO2. This parameter is a function of various geologic factors including net-to-gross ratio, effective-to-total porosity, and the areal, vertical, and macroscopic displacement efficiency [a full review is presented by Bachu (2015)]. By generalising \( e_{{{\text{CO}}_{2} }} \) for similar reservoir or storage units, engineers can estimate the total mass of CO2 that can be stored in the storage site by \( {\text{MIP}}_{{{\text{CO}}_{2} }} = V_{\text{p}} \times e_{{{\text{CO}}_{2} }} \times \rho_{{{\text{CO}}_{2} }} \). In numerical simulations, \( e_{{{\text{CO}}_{2} }} \) can be derived by either calculating \( {\text{MIP}}_{{{\text{CO}}_{2} ,{\text{gas}}}} \) first, and extracting \( e_{{{\text{CO}}_{2} }} \), or by directly calculating the volume of free-gas CO2 from the numerical gridblocks of the domain with the pore volume of \( V_{\text{p}} \):

$$ e_{{V,{\text{CO}}_{ 2} }}^{t} = \frac{{\sum\nolimits_{i = 1}^{{N_{\text{b}} }} {S_{{{\text{g}},i}}^{t} V_{i} \phi_{i}^{t} } }}{{V_{\text{p}} }} $$
(4)

where Nb is the number of gridblocks within the domain, and \( S_{{{\text{g}},i}} \), \( V_{i} \), and \( \phi_{i} \) are ith gridblock gas saturation, volume and porosity, respectively, at the end of simulation.

3.2.2 Heat Recovery Metrics

The global net heat recovered by the operation is

$$ E_{\text{net}}^{t} = E_{\text{prd}}^{t} - E_{\text{inj}}^{t} $$
(5)

where \( E_{\text{inj}}^{t} \) and \( E_{\text{prd}}^{t} \) are, respectively, the energy injected by the injectors and energy produced by the producers, at time t. These are calculated based on the temperature of injection and production streams in ECLISPE E300.

The available heat in the rock and fluid at initial time is denoted by \( {\text{EIIP}} \) (energy initially in place) and is calculated from the porosity-averaged heat capacity of rock and brine:

$$ {\text{EIIP}} = \sum\limits_{i = 1}^{{N_{\text{b}} }} {V_{{{\text{b}},i}} e_{i} } = \sum\limits_{i = 1}^{{N_{\text{b}} }} {[\phi_{i} V_{i} (\hat{S}_{{{\text{g}},i}} b_{{{\text{g}},i}} e_{{{\text{g}},i}} + \hat{S}_{{{\text{w}},i}} b_{{{\text{w}},i}} e_{{{\text{w}},i}} + \hat{S}_{{{\text{s}},i}} b_{{{\text{s}},i}} e_{{{\text{s}},i}} ) + (1 - \phi_{i} )V_{i} e_{{{\text{r}},i}} ]} $$
(6)

where \( V_{{{\text{b}},i}} \) is the ith gridblock bulk volume, and \( e_{i} \) is the ith gridblock effective total energy; \( e_{{{\text{g}},i}} \), \( e_{{{\text{w}},i}} \), and \( e_{s,i} \) (kJ/kg mol) are, respectively, ith gridblock internal-energy molar densities of gas, water and solid phases; \( b_{{{\text{g}},i}} \), \( b_{{{\text{w}},i}} \) and \( b_{{{\text{s}},i}} \) (kg mol/m3) are, respectively, molar densities of gas, water and solid phases; and \( e_{{{\text{s}},i}} \) (kJ/m3) is the energy per unit volume of rock calculated from rock heat capacity and rock density. Phase internal-energy densities and phase enthalpies are assumed to be equal (\( U = H \)). A geothermal heat recovery factor is defined as:

$$ r_{\text{g}}^{t} = \frac{{E_{\text{net}}^{t} }}{\text{EIIP}} $$
(7)

In summary, in a multiparametric analysis of performance of the operation, the effect of well number, open versus close systems and injection rate on \( M_{\text{net}}^{t} \) and \( e_{\text{inj}}^{t} \), \( e_{{V,{\text{CO}}_{ 2} }}^{t} \) and \( r_{\text{g}}^{t} \) are compared. Additionally, max (\( \hat{S}_{\text{s}}^{t} \)) (maximum solid saturation at time t) between the simulation runs are compared.

4 Results

4.1 System Behaviour

I start presenting results for operation with production Pbh of 200 bar. Figure 3 shows the gas saturation distribution for the lowest injection rate (1.5 × 106 sm3/day) for different well patterns after 5 years of injection. The reason year 5 is chosen, is that around this year the plumes start to reach the production wells, and thereafter, the CO2 is back-produced (as will be shown in Fig. 5). Similar to the work of Heath et al. (2014), the discrepancy between the CO2 saturation distributions of the close and open systems is only dramatic for the 3 × 3 well pattern. The discrepancy becomes negligible by increasing the number of wells. Figure 4 shows the pressure distribution after 5 years of injection.

Fig. 3
figure 3

The gas saturation distribution in the domain after 5 years of injection for volumetric injection rate of 1.5 × 106 sm3/day

Fig. 4
figure 4

The pressure distribution in the domain after 5 years of injection for Q = 1.5 × 106 sm3/day

The cumulative total fluid (water and gas) production, cumulative water production and cumulative gas production, separately, are shown in Fig. 5 for various simulation runs with production Pbh = 200 bar. At standard conditions, the volume of gas dominates the production. Therefore, alongside the system boundaries, it is responsible for pressure build-up/relief in the system as shown in Fig. 6. Due to the ability of gas to escape into the boundaries, the 3 × 3 well pattern in open system represents the least production of fluid. The open boundaries also prevent the pressurisation during the first 5 years of operation compared to the 3 × 3 well pattern in close system. The plumes expand away the four production wells into the boundaries in this case (Fig. 3). Although as described in “Appendix B” the pressure build-up for the 3 × 3 well patterns is not exceeding the maximum allowable pressure in the wells, higher injection rates may jeopardise the integrity of the caprock. The influence of system boundaries on pressure build-up becomes less pronounced by increasing number of wells in the 5 × 5 and 7 × 7 well patterns. In the longer 20-year window, however, for all the simulations, the pressure build-up for open and close systems converges. This shows that a circulation of CO2 is established.

Fig. 5
figure 5

The fluid extraction/gas production/water production profiles for a, d, gQ = 1.5 × 106 sm3/day, b, e, hQ = 3 × 106 sm3/day and c, f, iQ = 4.5 × 106 sm3/day

Fig. 6
figure 6

The pressure profiles for aQ = 1.5 × 106 sm3/day, bQ = 3 × 106 sm3/day and cQ = 4.5 × 106 sm3/day

4.2 CO2 Storage Metrics

The conclusion made earlier (reduction in the impact of system boundaries on performance measures) is corroborated by calculating CO2 storage efficiency (\( e_{{V,{\text{CO}}_{ 2} }}^{t} \)) throughout the simulation for different runs as shown collectively in Fig. 7. While, the curves are different in magnitude for the 3 × 3 well pattern between close and open systems, the discrepancy between the curves has decreased for the 5 × 5 well pattern, and the curves have almost converged with a negligible difference for the 7 × 7 well pattern. By increase in the injection rate, \( e_{{V,{\text{CO}}_{ 2} }}^{t} \) has increased regardless of the system boundaries. The values of \( e_{{V,{\text{CO}}_{ 2} }}^{t} \) here are larger than the typical values obtained for CO2 storage in saline aquifers because (1) brine is extracted in CO2–geothermal heat recovery that enhances the storage efficiency significantly and (2) circulation and back-production of CO2 is allowed.

Fig. 7
figure 7

The CO2 storage efficiency for aQ = 1.5 × 106 sm3/day, bQ = 3 × 106 sm3/day and cQ = 4.5 × 106 sm3/day

Figure 8 shows \( M_{\text{net}}^{t} \) for various simulation runs. There is a slight advantage in operating with the 3 × 3 well pattern in close system over 5 × 5 and 7 × 7 well patterns in terms of allowing more CO2 to be stored in the geothermal system by the end of simulation. In contrast, for the open boundary condition, the 3 × 3 well pattern does not recover CO2 from the production wells as efficiently as in the 5 × 5 and 7 × 7 well patterns. Considering that the storage efficiency is the same between the well patterns for open boundary conditions, one can deduct that the injected CO2 is being lost only to the surrounding side aquifers for the 3 × 3 well pattern in open system. For the 3 × 3 well pattern in close system, since there is no loss of CO2 to the side aquifers, and the amounts of CO2 staying in the geothermal system is almost the same for all the well patterns, the pressure build-up can only be attributed to lower fluid extraction levels. Hence, a higher pressure of the system applied on the CO2 will result in lower volumes of the plume, thereby reducing the storage efficiency, \( e_{{V,{\text{CO}}_{ 2} }}^{t} \) compared to 5 × 5 and 7 × 7 well patterns. Finally as of \( e_{{V,{\text{CO}}_{ 2} }}^{t} \), the increase in operating injection rate has positive feedback on the net mass of stored CO2 in the system.

Fig. 8
figure 8

The accumulated mass of CO2 for aQ = 1.5 × 106 sm3/day, bQ = 3 × 106 sm3/day and cQ = 4.5 × 106 sm3/day

Figure 9 shows the profile of injection efficiency factor (\( e_{\text{inj}}^{t} \)). The curves demonstrate a slight decrease in \( e_{\text{inj}}^{t} \) by increase in injection rate.

Fig. 9
figure 9

The CO2 injection efficiency factor for aQ = 1.5 × 106 sm3/day, bQ = 3 × 106 sm3/day and cQ = 4.5 × 106 sm3/day

4.3 Geothermal Heat Recovery

Figure 10 shows the profiles of geothermal heat recovery factor (\( r_{\text{g}}^{t} \)) for various simulation runs. Following interpretations can be deducted from this figure:

Fig. 10
figure 10

The geothermal heat recovery factor for aQ = 1.5 × 106 sm3/day, bQ = 3 × 106 sm3/day and cQ = 4.5 × 106 sm3/day

  1. (1)

    Close system has resulted in higher heat recovery factors than the open system for all the well patterns considered in this study. This can be attributed to the negative role of the additional pore volume that allows migration of brine and CO2 from the main domain of the geothermal system. CO2 in its way pushes the hot aquifer brine away from the extraction wells, leading to poorer heat recovery. This is corroborated by considering the additional \( M_{\text{net}}^{t} \) that the open boundary condition accommodates compared to close boundary condition.

  2. (2)

    Regardless of the boundaries being open or close, increasing the number of wells result in higher heat recovery factors by allowing more extracted volumes of fluids as shown in Fig. 5. The negative impact of boundary condition on heat recovery factor can be alleviated by increasing the number of wells, so that the difference between open and close systems of higher than 0.02 for the 3 × 3 well pattern will decrease to less than 0.01 for 7 × 7 well pattern.

  3. (3)

    The increase in operating injection rate has a positive feedback on heat recovery, and the discrepancy of the profiles between open and close systems will be higher for higher injection rates.

4.4 Salt Precipitation

Figure 11 shows the maximum solid saturation accumulated in the system during the simulation. Previously, solid precipitation in the context of CO2 injection–geothermal heat recovery operations has been modelled and effects of salt precipitation have been investigated (Borgia et al. 2012; Xu et al. 2008; Tutolo et al. 2015; Xu et al. 2006). Following are the interpretations from Fig. 11:

Fig. 11
figure 11

The average solid saturation in the system for aQ = 1.5 × 106 sm3/day, bQ = 3 × 106 sm3/day and cQ = 4.5 × 106 sm3/day

  1. (1)

    There is a sharp decrease in max (\( \hat{S}_{\text{s}} \)) by increasing the well numbers and a nonlinear increase by increasing the injection rate. This can be attributed to the distribution of injection between more injection wells in the 7 × 7 well pattern than in the 3 × 3 well pattern. Using Eq. (A7) ~ 30% permeability reduction at injection sites for the 3 × 3 well pattern is estimated. For the 5 × 5 well pattern, only for the highest injection rate ~ 30% permeability reduction occurs, and this reduction never occurs for 7 × 7 well pattern.

  2. (2)

    The open or close boundaries have played no role in the magnitude and trend of the profiles. Since the initial conditions imposed such as pressure, temperature and salt mass fraction are comparable with CO2 storage analysis conducted by Guyant et al. (2015), the results are also comparable with their findings. The initial salt mass fraction leads to uniform precipitation of salt (not localised away from injection wells as for high-k case). However, since the model here is based on a single-effective porosity, the results are not comparable with solid saturation distribution in a deep EGS as shown in Borgia et al. (2012, Fig. 7b) where the salt saturation is non-uniform and localised.

  3. (3)

    max (\( \hat{S}_{\text{s}} \)) has a non-reducing upper limit of ∼ 0.08 for the 3 × 3 well pattern. Upper limit of max (\( \hat{S}_{\text{s}} \)) is higher for the 5 × 5 well pattern, is achieved only for the highest injection near the end of simulation. Upper limit of max (\( \hat{S}_{\text{s}} \)) is not achieved for the 7 × 7 well pattern. Continuing the simulation may result in higher values for max (\( \hat{S}_{\text{s}} \)) for the 5 × 5 and 7 × 7 well patterns. Salt deposition is accelerated by increasing the injection rate; however, its magnitude is injection rate independent. This result is comparable with conclusions derived by Pruess and Müller (2009) and Zeidouni et al. (2009). Injection of fresh brine at injection wells can re-dissolve the salt and retrieve the injectivity of the injection wells.

It should be noted that, prediction max (\( \hat{S}_{\text{s}} \)) is extremely sensitive to the grid resolution (“Appendix C”) as it is a function of the gridblock volume. Using higher resolution grid, the trend and magnitude of max (\( \hat{S}_{\text{s}} \)) may vary significantly. This will have implications in terms of how porosity and permeability are affected by salt deposition near wellbore. As such, a careful investigation on how salt deposition is predicted by the simulation grid resolution is required. This will remain a matter of future investigations.

4.5 Impact of Bottomhole Pressure

Figure 12 condenses the output metrics discussed above calculated from simulations with Pbh of 200, 180 and 160 bar. For brevity purposes, only the results for the 3 × 3 well pattern and Q = 4.5 × 106 sm3/day are shown. Following are the interpretations extracted from Fig. 12:

Fig. 12
figure 12

The comparison of different output metrics for varying production Pbh simulations. a Injection Pbh profiles of the middle injection well, b storage efficiency factor, c the net amount of CO2 in place, d the injection efficiency factor, e geothermal heat recovery factor, and f the average solid saturation

  1. (1)

    Fig. 12a, the reservoirs will be under hydrostatic pressure because of over-production of fluid by the end of simulations for Pbh = 180 bar and Pbh = 160 bar. The support of open boundaries clearly helps to reduce the pressure drawdown.

  2. (2)

    Fig. 12b, c shows that having open boundaries may not always help to maximise the injectivity, as in the case for Pbh = 180 bar and Pbh = 160 bar, the injected CO2 is first pushed to the outside of the domain in the open boundaries, and later (year 10) it starts to migrate back to the main domain to be produced by the production wells. The CO2 back-production for Pbh = 160 bar is so high that the actual amount of CO2 staying in the domain for close boundaries by the end of simulation is higher than its counterpart simulation with open boundaries, and final \( e_{{V,{\text{CO}}_{ 2} }}^{t} \) is higher for close boundaries.

  3. (3)

    In Fig. 12d, the injection efficiency pattern remains the same as for previous examples by changing the production Pbh.

  4. (4)

    In Fig. 12e the profiles of geothermal heat recovery factor show an increase in energy recovery by decreasing the production Pbh and allowing more fluid production. The interesting result here is that even for the case that CO2 has returned to the production wells (Pbh = 180 bar and Pbh = 160 bar), the close system leads to higher recovery factors. The discrepancy between open and close systems for Pbh = 160 is the least, showing that more fluid production may finally offset the negative effects of open boundaries on heat production. Overall, in all the simulations performed by the 3 × 3 well pattern, the close boundaries are more favourable to mine heat from the subsurface system, since brine has no paths except for production. This may be counter-intuitive. However, the model under study is bounded from top and base by thermally insulating units, and the timescale of simulation cannot incorporate the onset and positive feedback of thermal density-driven convection that is normally in matter of 100 years (Ennis-King and Paterson 2005; Plaksina and White 2016). Therefore, the open boundaries have served only as escape paths for fluids and reduced the heat and fluid production.

  5. (5)

    Finally Fig. 12f shows no effects of varying production Pbh on the maximum solid precipitation.

5 Conclusions and Future Considerations

The communication or lack of hydrologic communication of a geothermal system with its surrounding aquifer has profound effects on performance of integrated CO2 sequestration—heat recovery operations, especially if the budget of the operation can be exhausted by large number of operating injection/production wells. If the aquifer is compartmentalised by sealing faults so that boundaries could be assumed as fully close, injecting CO2 can help to produce the pressure required for fluid production by generating a steep pressure gradient between injection and production wells. However, this pressure can build up excessively so that pressure management will be required either by reducing the injection rate throughout the injection operation or allowing more fluid extraction by lowering the minimum operational production bottomhole pressure. For the same system of close boundaries, while the fluid production impacts positively the performance of heat production from the system, it leads to negative impact on the synergistically intended carbon sequestration side of the project by back-producing CO2 from production wells. Therefore between objectives of the operation, there is a conflict. If the system under operation is diagnosed to possess hydrologically open boundaries with unhindered flow, heat and pressure communications with the surrounding, the fate of operation with large well spacing depends strongly on minimum operational production bottomhole pressure. In this case, one must calculate the direction of pressure gradient. If the gradient remains largely towards the outside of the geothermal system for large part of the operation, it means that the fluid will be pushed outside which benefits the operation in terms of additional CO2 storage injectivity, efficiency and net cumulative amounts. However, against this benefit, the geothermal heat recovery is undermined, as there is a sharp decrease in hot resident fluid production. If the pressure gradient is towards the inside of the geothermal system, i.e. the operation is underpressurising the system, in expense of adversely affected CO2 storage efficiency and injectivity, the fluid production is enhanced and the relative heat recovery loss compared to close boundaries is offset.

Above-mentioned discrepancies between open and close systems disappear when the number of wells is increased and the well spacing becomes smaller, albeit with additional cost of drilling more wells. An engineering cost-effective trade-off analysis is then required to make judicious decisions as to how many wells can be drilled in an area of a geothermal system, so that the effects of boundaries (or uncertainty in them) are minimised.

The conclusions above are based on over-simplifying aquifer representation. Although it was tried to make the hot sedimentary aquifer under study as representative as possible (for example a computationally heavy 3D model rather than 2D was consider), realistically there are complexities in terms of

  • Heterogeneity in porosity, permeability, net to gross

  • Conductive heat flux

  • Dynamic time-dependent water influx from boundaries and large-scale groundwater stream flows.

Above-mentioned factors should be included in future research works. For example, heterogeneity will impact storage efficiency and heat recovery factor. However, the interplay of heterogeneity and system boundaries is a matter of investigation. Additionally for an EGS system with carbon sequestration as an ancillary objective, the effect of boundaries may elucidate interesting deductions: if the flow paths through man-made fractures have extended beyond targeted zone, or they remain fully inside the targeted zone so that no flow leakages occur across the boundaries.