Abstract
Gastrointestinal (GI) impedance carries useful information about the physiology of GI organs. This chapter presents the development and applications of impedance measuring techniques for the diagnosis of diseases affecting different GI organs. Following this, several new concepts of encapsulating catheter-based GI monitoring systems are introduced, among them, a novel gastric-retentive impedance measurement system known as transcutaneous intraluminal impedance measurements (TIIM), are explained in the second section of this chapter. Finally, the main advantages of capsule-based GI impedance measurements are discussed.
References
Deneva MG, Yadid-Pecht O, Fattouche M, Mintchev MP (2012) Utilization of temporary controllable intragastric pseudobezoars for the treatment of obesity. Curr Obes Rep 1(2):68–74
Filip D, Yadid-Pecht O, Mintchev MP (2010) Progress in self-stabilizing capsules for imaging of the large intestine. In: 17th IEEE International Conference of Electronics, Circuits, and Systems, Athens, 2010
Filip D, Yadid-Pecht O, Andrews CN, Mintchev MP (2011) Self-stabilizing colonic capsule endoscopy: pilot study of acute canine models. IEEE Trans Med Imaging 30(12):2115–2125
Gonzalez JL, Sadowski DC, Mintchev MP (2006) Friction-assisted magnetic holding of an ingestible capsule for esophageal pH and impedance monitoring. In: Proceedings of the 28th IEEE EMBS annual international conference, New York City, 2006
Gonzalez JL, Sadowski DC, Kaler KVIS, Mintchev MP (2007) Ingestible capsule for impedance and pH monitoring in the esophagus. IEEE Trans Biomed Eng 54(12):2231–2236
Gregersen H (2005) Impedance planimetry: application for studies of rectal function. In: Complex anorectal disorders. Springer, London, pp 72–104
Gregersen H, Andersen MB (1991) Impedance measuring system for quantification of cross-sectional area. Med Biol Eng Comput 29(1):108–110
Harris JH, Therkelsen EE, Zinner NR (1971) Electrical measurement of ureteral flow. In: Urodynamics. Academic, London, pp 465–472
Imam H, Sanmiguel C, Larive B, Bhat Y, Soffer E (2004) Study of intestinal flow by combined videofluoroscopy, manometry, and multiple intraluminal impedance. Am J Physiol Gastrointest Liver Physiol 286(2):263–270
McClelland GR, Sutton JA (1985) Epigastric impedance: a non-invasive method for the assessment of gastric emptying and motility. Gut 26(6):607–614
Mintchev MP, Deneva MG, Aminkov BI, Fattouche M, Yadid-Pecht O, Bray RC (2010) Pilot study of temporary controllable gastric pseudobezoars for dynamic non-invasive gastric volume reduction. Physiol Meas 31(2):131–144
Nguyen HN, Silny J, Wüller S, Marschall HU, Rau G, Matern S (1997) Abnormal postprandial duodenal chyme transport in patients with long standing insulin dependent diabetes mellitus. Gut 41(5):624–631
Nguyen HN, Domingues GR, Winograd R, Lammert F, Silny J, Matern S (2004) Impedance characteristics of esophageal motor function in achalasia. Dis Esophagus 17(1):44–50
Poscente MD, Hussain A, Filip D, Andrews CN, Mintchev MP (2013) Transcutaneous intraluminal impedance measurements (TIIM): a new minimally-invasive technique for long-term monitoring of gastric motility. Gastroenterology 144(5):S737–S738
Shay S, Tutuian R, Sifrim D, Vela M, Wise J, Balaji N, Zhang X, Adhami T, Murray J, Peters J, Castell D (2004) Twenty-four hour ambulatory simultaneous impedance and pH monitoring: a multicenter report of normal values from 60 healthy volunteers. Am J Gastroenterol 99(6):1037–1043
Smout AJPM, Jebbink HJA, Akkermans LMA, Bruijs PPM (1994) Role of electrogastrography and gastric impedance measurements in evaluation of gastric emptying and motility. Dig Dis Sci 39(12):110S–113S
Sutton JA, Thompson S, Sobnack R (1985) Measurement of gastric emptying rates by radioactive isotope scanning and epigastric impedance. Lancet 325(8434):898–900
Tutuian R (2008) Impedance technology for the management. Eur Surg 40(2):50–57
Wang G, Poscente MD, Filip D, Yadid-Pecht O, Andrews CN, Mintchev MP (2014) Mo1302 Gastric-Retentive Transcutaneous Intraluminal Impedance Measurement (TIIM): Sham Controlled, Minimally-Invasive Assessment of Gastric Motility in Acute Canine Models, Gastroenterology, 146(5): p S613.
Webster JG (1998) Medical instrumentation: application and design. Wiley, New York
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2015 Springer Science+Business Media New York
About this entry
Cite this entry
Wang, G., Filip, D., Poscente, M.D., Andrews, C.N., Mintchev, M.P. (2015). Capsule-Based Measurements of Gastrointestinal Impedance. In: Sawan, M. (eds) Handbook of Biochips. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-6623-9_17-1
Download citation
DOI: https://doi.org/10.1007/978-1-4614-6623-9_17-1
Received:
Accepted:
Published:
Publisher Name: Springer, New York, NY
Online ISBN: 978-1-4614-6623-9
eBook Packages: Springer Reference EngineeringReference Module Computer Science and Engineering