Abstract
This chapter touches the system configurations of solar assisted ground source heat pumps, giving an overview of the main system components at first. Series and parallel/dual sources configurations have been discussed for a technical point of view, identifying main operating modes in accordance with the use of the produced solar heat. Indicators for assessing energy performance of main system components singularly and overall system have been also presented, paying attention also on the final energy supply chain from the used energy fuels.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Bakirci K, Ozyurt O, Comakli K, Comakli O (2011) Energy analysis of a solar-ground source heat pump system with vertical closed-loop for heating applications. Energy 36:3224–3232. doi:10.1016/j.energy.2011.03.011
Dai L, Li S, DuanMu L, Li X, Shang Y, Dong M (2015) Experimental performance analysis of a solar assisted ground source heat pump system under different heating operation modes. Appl Therm Eng 75:325–333. doi:10.1016/j.applthermaleng.2014.09.061
Dott R, Afjei T, Genkinger A, Dalibard A, Carbonell D, Consul R, Heinz A, Haller M, Witzig A, Facão J, Ochs F, Pärisch P (2013) Models of sub-components and validation for the IEA SHC Task 44/HPP Annex 38 Part C: heat pump models. A technical report of subtask C Report C2 Part C—Final Draft
Emmi G, Zarrella A, De Carli M, Galgaro A (2015) An analysis of solar assisted ground source heat pumps in cold climates. Energy Convers Manag 106:660–675. doi:10.1016/j.enconman.2015.10.016
EnergyPlus Weather Data | EnergyPlus. https://energyplus.net/weather
Fidorów N, Szulgowska-Zgrzywa M (2015) The influence of the ground coupled heat pump’s labor on the ground temperature in the boreholes—study based on experimental data. Appl Therm Eng 82:237–245. doi:10.1016/j.applthermaleng.2015.02.035
Helpin V, Kummert, Cauret O (2011) Experimental and simulation study of hybrid ground-source heat pump systems with unglazed solar collectors for french office buildings. In: Proceedings of the 12th conference of International Building Performance Simulation Association, Sydney, 14–16 (Department of Mechanical Engineering, École Polytechnique de Montréal, QC, Canada and Department “Energy in buildings and territories”, EDF R&D, France)
Jalaluddin, Miyara A (2015) Thermal performance and pressure drop of spiral-tube ground heat exchangers for ground-source heat pump. Appl Therm Eng 90:630–637. doi:10.1016/j.applthermaleng.2015.07.035
Lazzarin RM (2012) Dual source heat pump systems: operation and performance. Energy Build 52:77–85. doi:10.1016/j.enbuild.2012.05.026
Li T, Liu Y, Wang D, Shang K, Liu J (2015) Optimization analysis on storage tank volume in solar heating system. Procedia Eng 121:1356–1364. doi:10.1016/j.proeng.2015.09.019
Loose A, Drück H (2014) Field test of an advanced solar thermal and heat pump system with solar roof tile collectors and geothermal heat source. Energy Procedia 48:904–913. doi:10.1016/j.egypro.2014.02.104
Malenković I, Pärisch P, Eicher S, Bony J, Hartl M (2013) Definition of main system boundaries and performance figures for reporting on SHP systems deliverable B1
Mehrpooya M, Hemmatabady H, Ahmadi MH (2015) Optimization of performance of combined solar collector-geothermal heat pump systems to supply thermal load needed for heating greenhouses. Energy Convers Manag 97:382–392. doi:10.1016/j.enconman.2015.03.073
Meteonorm, Meteonorm: irradiation data for every place on Earth. http://www.meteonorm.com/
Ochs F, Carbonell D, Haller M (2012) Models of sub-components and validation for the IEA SHC Task 44/HPP Annex 38 Part B : collector models IEA solar heating and cooling programme
Piscaglia F, Blasi A, Del Moro S, Polonara F, Arteconi A, Zanarelli L, Renzulli A (2016) Monitoring of a vertical borehole ground-coupled heat pump system: a case study from a marly-limestone heat reservoir (Urbino, Central Italy). Geothermics 62:61–69. doi:10.1016/j.geothermics.2016.02.008
Reda F, Laitinen A (2015) Different strategies for long term performance of SAGSHP to match residential energy requirements in a cold climate. Energy Build 86:557–572. doi:10.1016/j.enbuild.2014.10.056
Reda F, Arcuri N, Loiacono P, Mazzeo D (2015) Energy assessment of solar technologies coupled with a ground source heat pump system for residential energy supply in Southern European climates. Energy 91:294–305. doi:10.1016/j.energy.2015.08.040
Renewable Resource Data Center—NREL NSRDB, 1961–1990: TMY2. http://rredc.nrel.gov/solar/old_data/nsrdb/1961-1990/tmy2/
TRNSYS Welcome | TRNSYS : Transient System Simulation Tool. http://www.trnsys.com/
Wang X, Zheng M, Zhang W, Zhang S, Yang T (2010) Experimental study of a solar-assisted ground-coupled heat pump system with solar seasonal thermal storage in severe cold areas. Energy Build 42:2104–2110. doi:10.1016/j.enbuild.2010.06.022
Xi C, Hongxing Y, Lin L, Jinggang W, Wei L (2011) Experimental studies on a ground coupled heat pump with solar thermal collectors for space heating. Energy 36:5292–5300. doi:10.1016/j.energy.2011.06.037
Yang W, Sun L, Chen Y (2015) Experimental investigations of the performance of a solar-ground source heat pump system operated in heating modes. Energy Build 89:97–111. doi:10.1016/j.enbuild.2014.12.027
ZAE Bayern Vacuum super insulated thermal storage—ZAE Bayern. http://www.zae-bayern.de/en/main-research-topics/energy-storage/projekte/vakuum-superisolierte-waermespeicher.html
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Copyright information
© 2017 The Author(s)
About this chapter
Cite this chapter
Reda, F. (2017). Solar Assisted Ground Source Heat Pump. In: Solar Assisted Ground Source Heat Pump Solutions. SpringerBriefs in Applied Sciences and Technology. Springer, Cham. https://doi.org/10.1007/978-3-319-49698-6_3
Download citation
DOI: https://doi.org/10.1007/978-3-319-49698-6_3
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-49696-2
Online ISBN: 978-3-319-49698-6
eBook Packages: EnergyEnergy (R0)