Abstract
A 28-year-old man presented with a Zone I open globe injury and an intraocular metal foreign body in the left eye. The metal foreign body was removed and the open globe was repaired. At the end of the case a slow wound leak was noticed and a bandage contact lens was placed. On post-operative day 1 the anterior chamber was shallow and the wound leak was sealed with corneal glue. Two weeks later the glue came loose and the wound leak persisted necessitating repeat corneal glue. Eight weeks post-operatively, the glue loosened and was removed along with the underlying sutures, and a wound leak was still present. The patient was taken to the operating room where the wound edges and overlying epithelium were debrided and the wound was re-sutured. After re-suturing, the wound remained watertight. Ten weeks after re-suturing, the corneal sutures were removed without complications, with a final visual acuity of 20/15.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Soong HK, Meyer RF, Wolter JR. Fistula excision and peripheral grafts in the treatment of persistent limbal wound leaks. Ophthalmology. 1988;95(1):31–6.
Kong GY, Henderson RH, Sandhu SS, Essex RW, Allen PJ, Campbell WG. Wound-related complications and clinical outcomes following open globe injury repair. Clin Exp Ophthalmol. 2015;43(6):508–13.
Orlin SE, Farber MG, Brucker AJ, Frayer WC. The unexpected guest: problem of iris reposition. Surv Ophthalmol. 1990;35(1):59–66.
Chen SH, Pineda R 2nd. Epithelial and fibrous downgrowth: mechanisms of disease. Ophthalmol Clin North Am. 2002;15(1):41–8. Review
Küchle M, Green WR. Epithelial ingrowth: a study of 207 histopathologically proven cases. Ger J Ophthalmol. 1996;5(4):211–23.
Weiner MJ, Trentacoste J, Pon DM, Albert DM. Epithelial downgrowth: a 30-year clinicopathologic review. Br J Ophthalmol. 1989;73(1):6–11.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer International Publishing AG, part of Springer Nature
About this chapter
Cite this chapter
Wolkow, N., Talcott, K.E., Grob, S. (2018). Case 46: Wound Leak After Open Globe Repair Requiring Corneal Glue and Re-suturing. In: Grob, S., Kloek, C. (eds) Management of Open Globe Injuries. Springer, Cham. https://doi.org/10.1007/978-3-319-72410-2_51
Download citation
DOI: https://doi.org/10.1007/978-3-319-72410-2_51
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-72409-6
Online ISBN: 978-3-319-72410-2
eBook Packages: MedicineMedicine (R0)