A 28-year-old man presented with a Zone I open globe injury and an intraocular metal foreign body in the left eye. The metal foreign body was removed and the open globe was repaired. At the end of the case a slow wound leak was noticed and a bandage contact lens was placed. On post-operative day 1 the anterior chamber was shallow and the wound leak was sealed with corneal glue. Two weeks later the glue came loose and the wound leak persisted necessitating repeat corneal glue. Eight weeks post-operatively, the glue loosened and was removed along with the underlying sutures, and a wound leak was still present. The patient was taken to the operating room where the wound edges and overlying epithelium were debrided and the wound was re-sutured. After re-suturing, the wound remained watertight. Ten weeks after re-suturing, the corneal sutures were removed without complications, with a final visual acuity of 20/15.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 109.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 139.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Soong HK, Meyer RF, Wolter JR. Fistula excision and peripheral grafts in the treatment of persistent limbal wound leaks. Ophthalmology. 1988;95(1):31–6.

    Article  CAS  PubMed  Google Scholar 

  2. Kong GY, Henderson RH, Sandhu SS, Essex RW, Allen PJ, Campbell WG. Wound-related complications and clinical outcomes following open globe injury repair. Clin Exp Ophthalmol. 2015;43(6):508–13.

    Article  PubMed  Google Scholar 

  3. Orlin SE, Farber MG, Brucker AJ, Frayer WC. The unexpected guest: problem of iris reposition. Surv Ophthalmol. 1990;35(1):59–66.

    Article  CAS  PubMed  Google Scholar 

  4. Chen SH, Pineda R 2nd. Epithelial and fibrous downgrowth: mechanisms of disease. Ophthalmol Clin North Am. 2002;15(1):41–8. Review

    Article  PubMed  Google Scholar 

  5. Küchle M, Green WR. Epithelial ingrowth: a study of 207 histopathologically proven cases. Ger J Ophthalmol. 1996;5(4):211–23.

    PubMed  Google Scholar 

  6. Weiner MJ, Trentacoste J, Pon DM, Albert DM. Epithelial downgrowth: a 30-year clinicopathologic review. Br J Ophthalmol. 1989;73(1):6–11.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Natalie Wolkow M.D., Ph.D. .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer International Publishing AG, part of Springer Nature

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Wolkow, N., Talcott, K.E., Grob, S. (2018). Case 46: Wound Leak After Open Globe Repair Requiring Corneal Glue and Re-suturing. In: Grob, S., Kloek, C. (eds) Management of Open Globe Injuries. Springer, Cham. https://doi.org/10.1007/978-3-319-72410-2_51

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-72410-2_51

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-72409-6

  • Online ISBN: 978-3-319-72410-2

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics