Layout and Planning of a University Hospital Clinical Cyclotron/PET Facility

  • Chapter
Chemists’ Views of Imaging Centers

Abstract

This paper describes the layout and planning of one of the most space efficient clinical PET centers built to date. It occupies 2250 square feet (NSF) of space. The RDS 112 self-shielded cyclotron and the chiller unit occupy about 650 NSF while the PET imaging section, containing the scanner room, ECAT control and computer rooms, receptionist office space, two patient preparation rooms, scan reading room and a break room occupy a total of 1010 NSF. Radiochemistry/pharmacy has only 590 NSF which includes office spaces for chemist, pharmacist, trainees and computers for cyclotron operation and patient management. The principal challenge was to build the radiochemistry facility in less than 300 NSF while remaining in compliance with OSHA, FDA and radiation safety regulations. This space is now occupied by two hot cells, a laminar flow hood for sterile preparation and pyrogen testing, a fume hood for dose drawing and HPLC/TLC preparation area, a radio-TLC scanner, two radio-HPLC and one radio-GC stations, a balance, an oven, a refrigerator, a dishwasher and a double sink with a DI water setup. We have been operating the facility since April, 1992 and are routinely producing 150–200 mCi of 18FDG and 20–25 mCi of 13NH3 with 98+ percent radiochemical purity and zero pyrogen level. In a typical production day the radiation levels vary from 0.1 to 2 mR/hr. The advantages and disadvantages of the layout are discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. SNM Newsline, J. Nucl. Med., 33, 40N (1992).

    Google Scholar 

  2. SNM Newsline, J. Nucl. Med., 30, 20N (1991).

    Google Scholar 

  3. Third Annual ICP Conference Listing, October (1991).

    Google Scholar 

  4. J.R. Dahl, R.D. Finn, J.L. Need, R.J. Nickles, S.M. Quaim, D.J. Schlyer and D.J. Silvester, Cyclotron Facilities: Layout and Planning. Proceedings of the Second Workshop on Targetry and Target Chemistry, Heidelberg, Sep. 22–25 (1987).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1995 Springer Science+Business Media New York

About this chapter

Cite this chapter

Bera, R.K., Yost, P., Hendershott, L.R., Gentilcore, R., Phegley, D., Fletcher, J.W. (1995). Layout and Planning of a University Hospital Clinical Cyclotron/PET Facility. In: Emran, A.M. (eds) Chemists’ Views of Imaging Centers. Springer, Boston, MA. https://doi.org/10.1007/978-1-4757-9670-4_4

Download citation

  • DOI: https://doi.org/10.1007/978-1-4757-9670-4_4

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4757-9672-8

  • Online ISBN: 978-1-4757-9670-4

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics