Abstract
Many airborne infectious diseases can be transmitted via exhaled contaminants transported in the air. Direct exposure occurs when the exhaled jet from the infected person directly enters the breathing zone of the target person. Indirect exposure occurs when the contaminants disperse in the room and are inhaled by the target person. This paper presents a simple method for differentiating the direct and indirect exposure to exhaled contaminants in mechanically ventilated rooms. Experimental data for 191 cases were collected from the literature. After analyzing the data, a simple method was developed to differentiate direct and indirect exposure in mixing and displacement ventilated rooms. The proposed method correctly differentiated direct and indirect exposure for 120 out of the 133 mixing ventilation cases and 47 out of the 58 displacement ventilation cases. Therefore, the proposed method is suitable for use at the early design stage to quickly assess whether there will be direct exposure to exhaled contaminants in a mechanically ventilated room.
Article PDF
Similar content being viewed by others
References
Baturin VV (1972). Fundamentals of Industrial Ventilation. Oxford, UK: Pergamon Press. pp. 79–119.
Berlanga FA, Olmedo I, Ruiz de Adana M (2017). Experimental analysis of the air velocity and contaminant dispersion of human exhalation flows. Indoor Air, 27: 803–815.
Bloch AB, Orenstein WA, Ewing WM, Spain WH, Mallison GF, Herrmann KL, Hinman AR (1985). Measles outbreak in a pediatric practice: Airborne transmission in an office setting. Pediatrics, 75: 676–683.
Bjørn E, Nielsen PV (2002). Dispersal of exhaled air and personal exposure in displacement ventilated rooms. Indoor Air, 12: 147–164.
Bocksell T (1998). An enhanced DRW model for turbulent particle diffusion. Master Thesis, University of Illinois at Urbana-Champaign, USA.
Cao G, Nielsen PV, Jensen RL, Heiselberg P, Liu L, Heikkinen J (2015). Protected zone ventilation and reduced personal exposure to airborne cross-infection. Indoor Air, 25: 307–319.
Chao CYH, Wan MP, Morawska L, Johnson GR, Ristovski ZD, et al. (2009). Characterization of expiration air jets and droplet size distributions immediately at the mouth opening. Journal of Aerosol Science, 40: 122–133.
Chen C, Zhao B (2010). Some questions on dispersion of human exhaled droplets in ventilation room: answers from numerical investigation. Indoor Air, 20: 95–111.
Chen C, Zhao B, Cui W, Dong L, An N, Ouyang X (2010). The effectiveness of an air cleaner in controlling droplet/aerosol particle dispersion emitted from a patient’s mouth in the indoor environment of dental clinics. Journal of the Royal Society Interface, 7: 1105–1118.
Chen C, Liu W, Li F, Lin CH, Liu J, Pei J, Chen Q (2013). A hybrid model for investigating transient particle transport in enclosed environments. Building and Environment, 62: 45–54.
Chen C, Lin CH, Jiang Z, Chen Q (2014a). Simplified models for exhaled airflow from a cough with the mouth covered. Indoor Air, 24: 580–591.
Chen C, Zhu J, Qu Z, Lin CH, Jiang Z, Chen Q (2014b) Systematic study of person-to-person contaminant transport in mechanically ventilated spaces (RP-1458). HVAC&R Research, 20: 80–91.
Chen C, Liu W, Lin C-H, Chen Q (2015a). Accelerating the Lagrangian method for modeling transient particle transport in indoor environments. Aerosol Science and Technology, 49: 351–361.
Chen C, Liu W, Lin CH, Chen Q (2015b). A Markov chain model for predicting transient particle transport in enclosed environments. Building and Environment, 90: 30–36.
Chen C, Liu W, Lin CH, Chen Q (2015c). Comparing the Markov chain model with the Eulerian and Lagrangian models for indoor transient particle transport simulations. Aerosol Science and Technology, 49: 857–871.
Chen L, Jin X, Yang L, Du X, Yang Y (2017). Particle transport characteristics in indoor environment with an air cleaner: The effect of nonuniform particle distributions. Building Simulation, 10: 123–133.
Ge Q, Li X, Inthavong K, Tu J (2013). Numerical study of the effects of human body heat on particle transport and inhalation in indoor environment. Building and Environment, 59: 1–9.
Habchi C, Ghali K, Ghaddar N (2014). A simplified mathematical model for predicting cross contamination in displacement ventilation air-conditioned spaces. Journal of Aerosol Science, 76: 72–86.
Hang J, Li Y, Jin R (2014). The influence of human walking on the flow and airborne transmission in a six-bed isolation room: Tracer gas simulation. Building and Environment, 77: 119–134.
Kanaan M, Ghaddar N, Ghali K (2016). Localized air-conditioning with upper-room UVGI to reduce airborne bacteria cross-infection. Building Simulation, 9: 63–74.
Lai ACK, Wong SL (2010). Experimental investigation of exhaled aerosol transport under two ventilation systems. Aerosol Science and Technology, 44: 444–452.
Lai ACK, Wong SL (2011) Expiratory aerosol transport in a scaled chamber under a variety of emission characteristics: an experimental study. Aerosol Science and Technology, 45: 909–917.
Li X, Niu J, Gao N (2012). Co-occupant’s exposure of expiratory droplets—Effects of mouth coverings. HVAC&R Research, 18: 575–587.
Li Y, Leung GM, Tang JW, Yang X, Chao CYH, et al. (2007). Role of ventilation in airborne transmission of infectious agents in the built environment—A multidisciplinary systematic review. Indoor Air, 17: 2–18.
Liu S, Novoselac A (2014). Transport of airborne particles from an unobstructed cough jet. Aerosol Science and Technology, 48: 1183–1194.
Liu Y, Zhao Y, Liu Z, Luo J (2016). Numerical investigation of the unsteady flow characteristics of human body thermal plume. Building Simulation, 9: 677–687.
Liu L, Li Y, Nielsen PV, Wei J, Jensen RL (2017). Short-range airborne transmission of expiratory droplets between two people. Indoor Air, 27: 452–462.
Menzies D, Fanning A, Yuan L, FitzGerald JM (2000). Hospital ventilation and risk for tuberculous infection in Canadian health care workers. Annals of Internal Medicine, 133: 779–789.
Moser MR, Bender TR, Margolis HS, Noble GR, Kendal AP, Ritter DG (1979). An outbreak of influenza aboard a commercial airliner. American Journal of Epidemiology, 110: 1–6.
Morawska L (2006). Droplet fate in indoor environments, or can we prevent the spread of infection? Indoor Air, 16: 335–347.
Morawska L, Johnson GR, Ristovski ZD, Hargreaves M, Mengersen K, Corbett S, Chao CYH, Li Y, Katoshevski D (2009). Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities. Journal of Aerosol Science, 40: 256–269.
Nicas M, Nazaroff WW, Hubbard A (2005). Toward understanding the risk of secondary airborne infection: Emission of respirable pathogens. Journal of Occupational and Environmental Hygiene, 2: 143–154.
Nielsen PV, Hyldgaard CE, Melikov A, Andersen H, Soennichsen M (2007). Personal exposure between people in a room ventilated by textile terminals—With and without personalized ventilation. HVAC&R Research, 13: 635–643.
Nielsen PV, Li Y, Buus M, Winther FV (2010). Risk of cross-infection in a hospital ward with downward ventilation. Building and Environment, 45: 2008–2014.
Nielsen PV, Zajas J, Litewnicki M, Jensen RL (2014). Breathing and cross-infection risk in the microenvironment around people. In: Proceedings of ASHRAE Winter Conference, NY-14-C020, New York, USA.
Olmedo I, Nielsen PV, Ruiz de Adana M, Jensen RL, Grzelecki P (2012). Distribution of exhaled contaminants and personal exposure in a room using three different air distribution strategies. Indoor Air, 22: 64–76.
Olmedo I, Nielsen PV, Ruiz de Adana M, Jensen RL (2013). The risk of airborne cross-infection in a room with vertical low-velocity ventilation. Indoor Air, 23: 62–73.
Olsen SJ, Chang H-L, Cheung TY-Y, Tang AF-Y, Fisk TL, et al. (2003). Transmission of the severe acute respiratory syndrome on aircraft. New England Journal of Medicine, 349: 2416–2422.
OSHA (2014). OSHA Technical Manual (OTM). Section II: Chapter 1, Personal sampling for air contaminants. Occupational Safety & Health Administration Available at https://www.osha.gov/dts/osta/otm/otm_ii/pdfs/otmii_chpt1_allinone.pdf. Accessed 17 Oct 17 2014.
Qian H, Li Y, Nielsen PV, Hyldgård CE, Wong TW, Chwang AT (2006). Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems. Indoor Air, 16: 111–128.
Qian H, Li Y, Nielsen PV, Hyldgaard CE (2008). Dispersion of exhalation pollutants in a two-bed hospital ward with a downward ventilation system. Building and Environment, 43: 344–354.
Rim D, Novoselac A (2009). Transport of particulate and gaseous pollutants in the vicinity of a human body. Building and Environment, 44: 1840–1849.
Wei J, Li Y (2016). Airborne spread of infectious agents in the indoor environment. American Journal of Infection Control, 44(Suppl): S102–S108.
Xie X, Li Y, Chwang AT, Ho PL, Seto WH (2007). How far droplets can move in indoor environments—Revisiting the Wells evaporation–falling curve. Indoor Air, 17: 211–225.
Yan Y, Li X, Tu J (2017). Numerical investigations of the effects of manikin simplifications on the thermal flow field in indoor spaces. Building Simulation, 10: 219–227.
Yang C, Yang X, Zhao B (2016). Person to person droplets transmission characteristics in unidirectional ventilated protective isolation room: The impact of initial droplet size. Building Simulation, 9: 597–606.
Yin Y, Gupta JK, Zhang X, Liu J, Chen Q (2011). Distributions of respiratory contaminants from a patient with different postures and exhaling modes in a single-bed inpatient room. Building and Environment, 46: 75–81.
You R, Chen J, Lin CH, Wei D, Chen Q (2017). Investigating the impact of gaspers on cabin air quality in commercial airliners with a hybrid turbulence model. Building and Environment, 111: 110–122.
Zhang L, Li Y (2012). Dispersion of coughed droplets in a fully-occupied high-speed rail cabin. Building and Environment, 47: 58–66.
Zhang TT, Yin S, Wang S (2011). Quantify impacted scope of human expired air under different head postures and varying exhalation rates. Building and Environment, 46: 1928–1936.
Zhao B, Guan P (2007). Modeling particle dispersion in personalized ventilated room. Building and Environment, 42: 1099–1109.
Zhou Q, Qian H, Ren H, Li Y, Nielsen PV (2017). The lock-up phenomenon of exhaled flow in a stable thermally-stratified indoor environment. Building and Environment, 116: 246–256.
Acknowledgements
This work was supported by the National Natural Science Foundation of China (No. 51708474).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Chen, C., Zhao, B., Lai, D. et al. A simple method for differentiating direct and indirect exposure to exhaled contaminants in mechanically ventilated rooms. Build. Simul. 11, 1039–1051 (2018). https://doi.org/10.1007/s12273-018-0441-0
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12273-018-0441-0