Dear Editor,
A normal d-dimer has been advocated as a strong predictor for favorable outcome in unselected patients with a medical emergency [1, 2] and patients with nonspecific complaints [3]. However, there is concern that if d-dimer was measured routinely, there would be an inappropriate increase in investigations to rule-out venous thromboembolic disease (VTE), notwithstanding the increased risk of VTE in COVID-19 [4, 5]. During the current SARS-CoV2 pandemic, 8 out of 22 Danish hospitals have routinely been measuring d-dimer on all patients with suspected SARS-CoV2 infection. This provided an opportunity to explore if this policy resulted in a marked increase in ultrasonography for deep venous thrombosis in the lower extremity, and CT pulmonary angiograms (CTA) and ventilation/perfusion (VQ) scans for pulmonary emboli.
Data were obtained from the Danish National Patient Registry on all hospital visits and procedures nationally for patients 18 years or older for the first 17 weeks of 2020 [6]. Difference-in-differences analyses with negative binomial regression models were used to determine if the incidence rate ratios of VTE investigations changed after routine d-dimer measurement was introduced. These analyses accounted for heterogeneity between hospitals and were adjusted for whether they were performed during the pandemic, sex, age, Charlson co-morbidity index, and suspected SARS-CoV2 infection (coded at discharge).
The study was approved by the Danish Patient Safety Authority (file no. 20/18426). No informed consent was required.
We included 500,873 hospital visits (Table 1). Crude and adjusted differences in incidence rate ratios for changes in use of lower extremity ultrasound were 0.88 (95% CI 0.69–1.12) and 0.89 (95% CI 0.70–1.15), for CTA 0.94 (95% CI 0.76–1.16) and 0.99 (95% CI 0.80–1.21), and for VQ scan 1.33 (95% CI 0.69–2.60) and 1.44 (95%CI 0.74–2.70), respectively.
Our data show that implementing routine measurement of d-dimer on patients suspected of SARS-CoV2 infection did not lead to increased downstream radiological investigations in a population highly representative of those attending Danish emergency departments [7]. There are two potential explanations for this. First, Danish clinicians could be aware of the limitations of d-dimer as stand-alone test and thus only use it is conjunction with a pre-test probability decision rule such as Wells’ criteria [8, 9]. Second, d-dimer was reported as part of a routine panel of tests and could have been used as a marker of disease severity and not just as a screening tool for VTE [10].
Yao et al. have shown d-dimer to be a strong prognostic factor in COVID-19 patients in China [11]. We suspect that the same would be the case in our population, but unfortunately, the values of the d-dimer tests were not available to us.
This study’s limitation is that the number of d-dimer results reported contemporaneously to the treating physician is unknown. Although, d-dimers were drawn in patients with suspected SARS-CoV2 infection, the incidence of this condition was very low at the time and, therefore, probably did not influence the response to the d-dimer results. Nevertheless, since there was an increase—albeit insignificant—in the number of VQ scans ordered, some physicians must have at least considered the possibility of venous thromboembolic events, which may have been based on awareness of the increased risk of emboli in COVID-19 patients recently reported [6].
These results suggest that routine measurement of d-dimers on all-comers to an acute unit will probably not result in an unnecessary increase of radiological investigations.
Data availability
Not available due to Danish law.
Code availability
Stata 15.0.
References
Lyngholm LE, Nickel CH, Kellett J, Chang S, Cooksley T, Brabrand M (2019) A negative D-dimer identifies patients at low risk of death within 30 days: a prospective observational emergency department cohort study. QJM Int J Med 112(9):675–680
ChJ NK, T C, R B, DP H, M B (2016) Combined use of the national early warning score and d-dimer levels to predict 30-day and 365-day mortality in medical patients. Resuscitation 106:49–52
Ch N, T K, C K, AS M, N G, R B (2016) Risk stratification using D-dimers in patients presenting to the emergency department with nonspecific complaints. Eur J Intern Med 31:20–24
Landi A, De Servi S (2020) The burden of thrombotic complications in critically ill patients with COVID-19: charting the uncharted. Intern Emerg Med 15(5):893–895. https://doi.org/10.1007/s11739-020-02393-1
Dubois-Silva Á, Barbagelata-López C, Mena Á, Piñeiro-Parga P, Llinares-García D, Freire-Castro S (2020) Pulmonary embolism and screening for concomitant proximal deep vein thrombosis in noncritically ill hospitalized patients with coronavirus disease 2019. Intern Emerg Med 15(5):865–870. https://doi.org/10.1007/s11739-020-02416-x
S M, Saj S, JL S, V E, L P, HT S (2015) The danish national patient registry: a review of content, data quality, and research potential. Clin Epidemol 7:449–490
Fløjstrup M, Bogh SB, Henriksen DP et al (2020) Increasing emergency hospital activity in Denmark, 2005–2016: a nationwide descriptive study. BMJ Open 10(2):e031409. https://doi.org/10.1136/bmjopen-2019-031409
Wells PS, Anderson DR, Rodger M, Forgie M, Kearon C, Dreyer J, Kovacs G, Mitchell M, Lewandowski B, Kovacs MJ (2003) Evaluation of D-dimer in the diagnosis of suspected deep-vein thrombosis. N Engl J Med 349(13):1227–1235. https://doi.org/10.1056/NEJMoa023153
Wells PS, Anderson DR, Rodger M, Stiell I, Dreyer JF, Barnes D, Forgie M, Kovacs G, Ward J, Kovacs MJ (2001) Excluding pulmonary embolism at the bedside without diagnostic imaging: management of patients with suspected pulmonary embolism presenting to the emergency department by using a simple clinical model and d-dimer. Ann Intern Med 135(2):98–107. https://doi.org/10.7326/0003-4819-135-2-200107170-00010
Nickel CH, Kellett J, Cooksley T, Lyngholm LE, Chang S, Imfeld S, Bingisser R, Brabrand M (2020) The diagnoses and outcomes of emergency patients with an elevated d-dimer over the next 90 days. Am J Med. https://doi.org/10.1016/j.amjmed.2020.06.009
Yao Y, Cao J, Wang Q, Shi Q, Liu K, Luo Z, Chen X, Chen S, Yu K, Huang Z, Hu B (2020) D-dimer as a biomarker for disease severity and mortality in COVID-19 patients: a case control study. J Intensive Care 8(1):49. https://doi.org/10.1186/s40560-020-00466-z
Acknowledgements
None.
Funding
No funding was received for conducting this study.
Author information
Authors and Affiliations
Contributions
All authors: study concept and design and critical revision of the manuscript. MB, SBB, MF: acquisition of data. MB, SBB: analysis and interpretation. MB: drafting of the manuscript.
Corresponding author
Ethics declarations
Conflicts of interest
Financial interests: JK is a major shareholder, director, and chief medical officer of Tapa Healthcare DAC. Non-financial interests: None.
Statement of human and animal rights
The study was approved by the Danish Patient Safety Administration.
Informed consent
Informed consent was not required by Danish law.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Brabrand, M., Bogh, S.B., Fløjstrup, M. et al. Routine measurement of d-dimers on suspected SARS-CoV2-infected patients does not lead to significant increase in radiological investigations. Intern Emerg Med 16, 1097–1098 (2021). https://doi.org/10.1007/s11739-020-02568-w
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11739-020-02568-w