Introduction

Nadolol belongs to a numerous group of pharmaceuticals blocking the β-adrenergic receptors, known as β-blockers, applied in the treatment of circulatory system. The main structural element of the majority of β-blockers is the aryloxyalkylaminopropanol group. Of particular, impact on the mechanisms of activity of this group of drugs are the substituents at the amino group, most often they are isopropyl groups of tert butyl groups—such as in nadolol, (Fig. 1). These substituents determine the degree of affinity to β-receptor of laevorotatory isomers. However, eventually the effectiveness of the drug depends on its aryl part as it controls the selectivity and activity towards adrenergic receptors. Nadolol comprises a two-ring aryl substituent—tetrahydronaphthalene—which means it acts nonselectively on β-adrenergic receptors β1 and β2.

Fig. 1
figure 1

Structure of nadolol

Nadolol is recommended for the treatment of hypertension, coronary disease and arrhythmia, moreover, according to recent studies it is also effective in the treatment of migraine and it can be safely applied against the above conditions even in the patients suffering from chronic mild asthma (Baker et al. 2011; Lopez-Sendon et al. 2004; Hanania et al. 2010).

The sterilization and decontamination of therapeutic drugs by exposition to ionizing radiation has been accepted by European Pharmacopoeia (European Pharmacopeia 2005) for many years. It offers a number of unquestionable advantages such as the possibility of sterilization in different forms and packages and at all temperatures, but it has a main drawback of the risk of drug deterioration by the ionizing radiation (Crucq et al. 2005). That is why it is so important to resolve the mechanism of radiodegradation of therapeutic drugs to be submitted to sterilization by irradiation (Marciniec and Dettlaff 2008).

The effect of gamma irradiation in the dose of 30 kGy on nadolol has been studied by a Belgian group (Engalytcheff et al. 2003, 2004). For analysis of the effect, they used the electron paramagnetic resonance (EPR) to evaluate the concentration of free radicals and ultra-high performance liquid chromatography (UHPLC) to detect the radiolysis products. The level of radiodegradation was found as <0.3% to give 1 main radiodegradation product and 12 other products in trace amounts. In comparison to the results obtained for the other seven β-blockers: acebutolol, atenolol, esmolol, labetalol, metoprolol, pindolol and propranolol, for nadolol the content of free radicals generated by irradiation was much higher; the radiation yield was 3.8 × 10−8 mol/J, so on average the number of free radicals was ten times higher than in the other β-blockers.

This paper is a continuation of our studies on the effects of ionizing irradiation on therapeutic drugs from the group of β-blockers (Marciniec et al. 2010, 2011; Ogrodowczyk et al. 2013, 2014, 2015). The aim of this study was determination of radiochemical stability of nadolol by spectrophotometric, thermal and chromatographic methods and identification of the products of its radiodegradation. To detect even the smallest changes in the drug taking place upon irradiation, often the doses of irradiation applied in the studies are much higher (100–400 kGy) than the standard dose used for sterilization (25 kGy) (European Pharmacopoeia 2014; CEN 1994).

Experimental

Materials

Nadolol, abbreviated as ND, (2R*,3S*)-5-{[(2R*)-3-(tert-butylamino)-2-hydroxypropyl]oxy}-1,2,3,4 tetrahydro-naphthalene-2,3-diol, molecular formula C17H27NO4, molecular weight 309.40, CAS number 42200-33-9. Fluka Analytical, Lot BCBB8918.

Irradiation with e-beam radiation

A few portions of approximately 0.5 g of nadolol were placed in separate transparent glass jars of 3 ml volume closed with plastic stoppers. The samples were irradiated with doses of 25, 50, 100, 200, 400 kGy of electron-beam radiation from a linear electron accelerator Elektronika 10/10, the energy of electrons was 9.96 MeV and the current intensity 6.2 μA.

Organoleptic analysis

The nadolol samples were examined before and after irradiation, to determine their appearance, colour, smell and clarity of the solution obtained by its dissolution in water, according to the European Pharmacopoeia (2014).

Fourier transform infrared spectroscopy (FT-IR)

KBr discs were prepared by mixing 1.00 mg of nadolol with 300 mg of KBr and compressing the samples obtained under a Pye Unicam minipress. The spectra were recorded using a Bruker IR spectrometer, in the range 500–4000 cm−1 with KBr as a blank. The apparatus was calibrated using water and its resolution was 2 cm−1.

Melting point determination

The melting points of nadolol were determined by the capillary method using MP 70 Melting Point System (Mettler Toledo). The measurements were performed for non-irradiated and irradiated nadolol samples (25, 50, 100, 200 and 400 kGy). The samples were heated from 25 to 139 °C, in the range 124–139 °C the heating rate was 1 °C/min. The result was an average of three measurements.

Differential scanning calorimetry (DSC)

Measurements were performed on an instrument DSC-50 Shimadzu, Japan. Samples of 2 mg were sealed in aluminium crucibles with pierced lids. The samples were thermally equilibrated at 20 °C for 5 min and the measurements were performed at a heating rate of 5 °C/min in nitrogen atmosphere (30 ml/min). For each sample, three independent measurements were performed and the results were averaged.

Ultra-high performance liquid chromatography coupled to mass spectrometry (UHPLC–MS)

UHPLC/TOF–MS experiments were carried out using an Ultra-Performance Liquid Chromatograph ACQUITY UPLC I-Class (Waters Inc.) coupled with Synapt G2-S HDMS (Waters Inc) mass spectrometer equipped with an electrospray ion source and q-TOF (tandem quadrupole/time of flight)-type mass analyser. The instrument was computer controlled and recorded data were processed using the MassLynx V4.1 software package (Waters Inc).

UHPLC separations were performed using a 2.1 × 100 mm BEH C18 (1.7 µm) column (Waters). Solvent A was water with 5 mM of CH3COONH4 and solvent B was acetonitrile. The gradient flow was used in all measurements. The gradient started with 5% of solvent B and increased to 100% of solvent B in 10 min than this condition was maintained for 3 min and the sample was brought back to the initial conditions. The flow rate was 0.3 ml/min.

All experiments were carried out using MSE mode providing simple spectra and the fragmentation spectra without ion pre-selection for every compound in the sample. Nitrogen was used as the nebulizer and cone gases. The tip voltage was kept at 3000 V. The cone voltage was set to 22 V. The collision energy (CE) for high-energy spectra was ramped from 20 to 40 eV. The resolving power FWHM (Full Width at Half Maximum) of the TOF analyser was 38000.

EPR spectroscopy

Continuous-wave X-band (9.4 GHz) electron paramagnetic resonance measurements were performed on a Bruker ELEXSYS E500 spectrometer with SuperX ER49X Microwave Bridge equipped with Super High Sensitivity Probehead (Bruker BioSpin GmbH, Rheinstetten, Germany). Magnetic field measurements were achieved by an NMT-Teslameter ER 036TM (Bruker BioSpin GmbH, Rheinstetten, Germany). All EPR experiments were performed at 295 K. Spin concentration was calculated after double integration of EPR spectra according to the procedure described elsewhere (Mai et al. 2013).

Calculation of radiation yield

Radiation yield is defined as the number of the degraded molecules of the reactant or the number of molecules of newly formed products to the amount of energy absorbed by the system. Radiation yield of nadolol free radicals (G FR) is defined as the ratio of free radicals formed as a result of irradiation with the energy of 100 eV:

$$G_{\text{FR}} = \frac{x}{{100\,{\text{ev}}}},$$

x number of molecules formed as a result of irradiation with energy of 100 eV.

1 kGy = 1000 Gy; 1 Gy = 100 rad; 1 rad = 6.243 × 1013 eV/g

Radiation yield can be also expressed in the SI units as mol/J.

Results and discussion

As recommended by the European Pharmacopoeia, the studies were begun with organoleptic examination. The ionizing radiation in the doses used did not generate changes in the form and smell of the drug. However, already after irradiation with the dose of 25 kGy, the colour of the sample changed from white to pale cream and after irradiation with higher doses (up to 4000 kGy) the colour changed into deeper cream. Organoleptic examination indicated that nadolol was sensitive to ionizing radiation and the colour change observed can be a consequence of formation of a colour product or products of radiolysis.

To verify this hypothesis the samples were subjected to melting point measurements by the capillary method and to differential scanning calorimetry (DSC) analysis. It is known that the presence of impurities including decomposition products and also radiodegradation products, causes a decrease in the melting point of a given drug. The melting point of non-irradiated nadolol sample was in the range 129.5–135.9 °C (Table 1) which is in agreement with literature values 124–136 °C (Moffat et al. 2011).

Table 1 Thermal analysis data obtained by means of DSC and capillary method

The DSC curve of non-irradiated nadolol showed one sharp endothermic peak at 133 °C (T max). In the curves recorded for the samples irradiated with increasing doses this peak was shifted towards lower temperatures in a proportional manner (Fig. 2). The linear relations between T onset and T max and the dose of irradiation are described by the correlation coefficients r = 0.9610 and r = 0.9234, respectively. The enthalpy of melting varied in the range 0.11–0.14 kJ/g (Table 1).

Fig. 2
figure 2

The DSC curves of nadolol before and after irradiation

At the next stage of the study, the samples were subjected to infrared spectrophotometric analysis. The FT-IR spectra of non-irradiated nadolol and the sample irradiated with 400 kGy (16 times the standard dose) are in full agreement and the intensity of bands at particular wavenumbers does not change (Fig. 3). This result indicates that the structure of the samples did not change and the products of radiodegradation occur in small amounts and their structures are probably similar to the parent compound. The identification of radiodegradation products and estimation of their amounts required chromatographic analysis coupled with mass spectrometry.

Fig. 3
figure 3

FT-IR spectra of nadolol before and after irradiation

The liquid chromatography analysis revealed the appearance of one major impurity and several minor ones as a result of irradiation (Fig. 4).

Fig. 4
figure 4

UHPLC-UV chromatograms of nadolol before (blue line) and after irradiation (25 kGy red line, 400 kGy green line)

The dehydration followed by the oxidation of second hydroxyl group to ketone and subsequent tautomerisation leading to the aromatization of the ring led to the formation of the main degradation product whose structure comprises that of naphthol (Fig. 5). This major impurity could be easily found in samples irradiated with the dose of 25 kGy. Other degradation products (Table 2.) were identified in the samples irradiated with the dose of 400 kGy.

Fig. 5
figure 5

The degradation paths of nadolol

Table 2 Impurities identified in the nadolol samples

The amount of the major impurity (H) was 0.3 and 2% in the samples irradiated with 25 and 400 kGy, respectively [these values were estimated as the respective peak area to the peak area corresponding to the main compound at a concentration of 0.2% to the nominal concentration (100%)]. Several structures for the minor impurities were proposed. They were mainly products of oxidation or dehydration processes of the nadolol molecule, and included also positional isomer of the major impurity (Fig. 5.).

The ESI–MS spectrum of the major impurity (RT = 8.76 min.) revealed a protonated ion m/z 290. The accurate mass measurement (290.1755 Da) indicated that the elemental composition of the protonated molecule was C17H24NO3. Under the same experimental conditions, nadolol produced the protonated ion m/z 310.2021 with the elemental composition C17H28NO4—Fig. 6.

Fig. 6
figure 6

The CID fragmentation spectra of nadolol (a) and impurity H (b)

During the fragmentation process of the m/z 290 ion (Fig. 7), iso-butene, ammonia and one hydroxyl group (instead of two observed in the nadolol fragmentation) were lost, which led to the most intense ion m/z 199.0751 instead of m/z 201.0917 observed for nadolol (Fig. 8). This suggested a significant structural similarity between the structures of the impurity and nadolol. The most informative to the structure elucidation of the major degradation product appeared to be the m/z 161.0599 ion with elemental composition C10H9O2. This ion was not present in the fragmentation spectrum of nadolol and the only structure fitting such a composition, which can be derived from the structure similar to nadolol, seemed to be the protonated dihydroxynaphthalene moiety. Most probably the naphthol structure cannot be formed in the fragmentation process but was present in the structure from the very beginning.

Fig. 7
figure 7

The fragmentation path of the impurity H-protonated molecule

Fig. 8
figure 8

The fragmentation path of nadolol-protonated molecule

The EPR signal of non-irradiated nadolol is beyond the level of the spectrometer sensitivity, so <0.1 ppm. The shape of EPR spectra of irradiated samples was found not to depend on the dose of irradiation and each spectrum indicates the presence of two types of radicals (Fig. 9a). The spectra show a broad intensive line L1 (26 Gs) characterised by g factor of g = 2.0043 (±0.0007) of inseparable hyperfine structure, and two weak lines L2 characterised by g factor values of g = 2.0261 and 1.9810, most probably coming from partly separated hyperfine structure. With increasing time after irradiation (Fig. 9b), lines L2 disappear and line L1 develops increasingly distinct lines assigned to hyperfine structure.

Fig. 9
figure 9

The EPR signal for nadolol: a non-irradiated and irradiated (24 h after irradiation); b. irradiated with the dose of 200 kGy versus time

Time changes in the number of free radicals in the samples of irradiated nadolol are illustrated in Fig. 10 by a mono-exponential function:

$$\begin{aligned} C(t) & = C_{f} + C_{0} e^{{\tfrac{ - t}{{T_{0} }}}} \\ T_{ 1/ 2} & = {\text{ln(2)}}T_{0} , \\ \end{aligned}$$

where C(t) is the concentration of radicals at time t, C f the concentration of stable (not undergoing recombination) radicals, C 0 the concentration of unstable radicals at time t = 0 (immediately after irradiation), T 0 the mean lifetime of unstable radicals, T 1/2 the half-lifetime of unstable radicals (undergoing recombination).

Fig. 10
figure 10

The decay of free radicals in the irradiated nadolol

Nadolol irradiated with the dose of 25 kGy does not contain unstable free radicals or they disappear in the time shorter than 24 h after irradiation. However, it contains the stable radicals in the concentration of 71.2 ppm—Fig. 10. The samples irradiated with doses of 100 and 200 kGy contain stable radicals in the concentration about three times greater than in the sample irradiated with 25 kGy and the unstable free radicals. The number of free radicals increases with increasing dose of irradiation but not in directly proportional manner. The lifetime of unstable free radicals in the sample irradiated with 200 kGy is 252 h and in the sample irradiated with 100 kGy it is 102 h.

The radiation yield GFR, defined as the ratio of the number of free radicals formed as a result of exposure to ionizing radiation of the energy 100 eV to the energy absorbed by the system, that can be expressed in mol/J, was calculated. The radiation yield GFR determined for the samples irradiated with the doses 25, 100 and 200 kGy was 8.88 × 10−2, 9.45 × 10−2 and 5.55 × 10−2 spin/100 eV (or in mol/J: 9.2 × 10−9, 9.8 × 10−9 and 5.8 × 10−9), respectively. The yield of free radical formation was the highest for the sample irradiated with 100 kGy, slightly lower for 25 kGy, while irradiation with the dose of 200 kGy led to the formation of a greater number of free radicals but the yield of this process was by almost 37–41% lower than that in the samples irradiated with 25 or 100 kGy. The GFR values obtained in our experiment made 14–25% (depending on the dose) of the radiation yield obtained in the experiment reported by Engalytcheff et al. (2003), which can be explained by different conditions of the process and a different source of irradiation. Comparison of the concentrations of free radicals formed in the same conditions (irradiated with radiation generated by a beam of electrons in the dose of 25 kGy) in nadolol and other β-blockers, has shown that in nadolol the amount of free radicals is much higher, (Fig. 11), that is about 10 times more than in pindolol and atenolol, 24–50 times more than in propranolol, metoprolol and acebutolol and 240 times more than in atenololol (Ogrodowczyk et al. 2013, 2014; Marciniec et al. 2008). Most probably, this significant difference is related to the presence of two additional hydroxyl groups in tetrahydronaphthalene.

Fig. 11
figure 11

The concentration of free radicals in nadolol and other β-blockers after irradiation (dose 25 kGy, e-beam) (Ogrodowczyk et al. 2013, 2014; Marciniec et al. 2008)

Conclusions

As a result of irradiation of nadolol in solid phase with e-beam radiation in the standard sterilization dose of 25 kGy (European Pharmacopoeia 2014; CEN 1994) its content decreases by about 0.3%. The reduction in nadolol content is directly proportional to the shift of the melting point. As follows from the results of our study, the DSC method can be used for a fast evaluation of radiodegradation of the compound at a level of 1–2%.

Another consequence of e-beam irradiation of nadolol is generation of free radicals in the concentration of 71.2 ppm, which is from 10 to 240 times more than their concentration observed for the other β-blockers subjected to sterilization in the same conditions. Most probably this very significant difference is related to the presence of two hydroxyl groups in the tetrahydronaphthalene ring. The same element of nadolol structure is involved in the main pathway of its radiodegradation, as the main product of radiodegradation is obtained by elimination of one of the OH groups from the tetrahydronaphthalene ring and aromatization of the ring (dehydration and dehydrogenation). The other radiolysis products are formed in trace amounts by dehydration and oxidation. The content of the main product of radiolysis which is an impurity undefined by the Pharmacopoeia (European Pharmacopoeia 2014) and a change in the colour of nadolol as a result of irradiation imply that the method of sterilisation with the standard dose cannot be applied to this drug.