Introduction

An elastance–resistance model is an effective tool to quantify the systolic pumping mechanics of the heart in in situ, open-chest experiments [5, 14, 21, 22]. Parameters generated by this model to characterize the cardiac physical processes are maximal systolic elastance (Emax) and theoretical maximum flow (Qmax). Physically, Emax can represent the intrinsic myocardial contractility in an intact heart because (1) it reflects subtle changes in the contractile status of the left ventricle and (2) it is independent of the preload, afterload, and heart rate for a given cardiac contractile state [11, 24]. Qmax is the amount of outflow generated by the ventricle if it were to eject under zero-load condition, and it shares an inverse relationship with the resistive behavior of the left ventricle [20, 22].

To develop an elastance–resistance model for assessing the cardiac pumping properties, simultaneously recording the left ventricular (LV) pressure and aortic flow (Qm) followed by recording the isovolumic LV pressure is indispensable [5, 14, 21, 22]. The ascending aorta-occlusive method must be used to measure the isovolumic LV pressure at the end of diastole under open-chest conditions. Obviously, the technique for recording the isovolumic LV pressure is not permitted in human patients. In 1997, Chang and Kuo [7] used a high-fidelity multi-sensor catheter to simultaneously measure the LV pressure and aortic flow in anesthetized, closed-chest dogs. A curve-fitting technique, proposed by Sunagawa et al. [26], was performed to estimate the isovolumic LV pressure by using the recorded instantaneous LV pressure of an ejecting contraction. They discovered that an elastance–resistance model with the estimated isovolumic LV pressure can potentially be used to study the systolic pumping mechanics of the heart.

In 1989, Kelly et al. [12] found that second zero crossing of fourth-order derivative of aortic pressure is close to peak of flow. The approximation of the aortic flow to a triangle (Qtri) was reported and validated by Westerhof et al. [29]. In their study, the timing of the peak of the triangle was derived using a fourth-order derivative of the aortic pressure waveform. Using Qtri, they successfully separated the measured aortic pressure pulse into its forward and backward components. In 2017, Wang et al. [28] evaluated a method for determining the slope (Ees) of the end-systolic pressure–volume relation (ESPVR) on the basis of the measured LV pressure and an assumed Qtri. In their study, Qtri was derived using a fourth-order derivative of the LV (but not aortic) pressure to approximate its corresponding Qm.

The present study elaborated these concepts by determining the LV Emax and Qmax by using the measured LV pressure without recording the isovolumic LV pressure and aortic flow signals. A single-beat estimation technique was employed to calculate the Emax and Qmax by using an elastance–resistance model based solely on the measurement of the LV pressure and cardiac output. The technique proposed by Sunagawa et al. [26] was used to estimate the isovolumic LV pressure from the measured LV pressure. An uncalibrated Qtri was constructed from the measured LV pressure based on the method proposed by Wang et al. [28]. The Qtri scale was calibrated using the cardiac output. Values of EmaxtriQ and QmaxtriQ obtained using Qtri were compared with those of EmaxmQ and QmaxmQ obtained from the measured Qm. Healthy rats (NC), rats with chronic kidney disease (CKD), and rats with type 1 or type 2 diabetes mellitus (DM) were analyzed. If the proposed method works out, the systolic elastic and resistive behaviors of the ventricular pump in human patients can be quantitated by using a minimally invasive measurement on the LV pressure together with non-invasive measurement on cardiac output.

Methods

Animals and catheterization

Male Wistar rats aged two months were divided into the following four groups: (1) NC (n = 25), (2) CKD (n = 14), (3) type 1 DM (n = 20), and (4) type 2 DM (n = 12). Female healthy rats (FNC; n = 7) were also included in the present study. According to the method reported by Floege et al. [9], CKD was induced through 5/6 subtotal nephrectomy (i.e., right nephrectomy and ligation of two branches of the left renal artery) in rats under anesthesia with sodium pentobarbital (50 mg kg−1; intraperitoneal). The levels of serum creatinine and blood urea nitrogen were determined using an autoanalyzer (Model 7070, Hitachi Electronics Co., Ltd., Tokyo, Japan). Type 1 DM was induced through a single-tail vein injection with 55 mg kg−1 streptozotocin (STZ; Sigma, St. Louis, MO, USA) in 0.1 M citrate buffer (pH 4.5; Sigma) [28]. Type 2 DM was induced by intraperitoneally administering 180 mg kg−1 nicotinamide (NA) (Sigma, St. Louis, MO, USA) 30 min before an intravenous injection of 50 mg kg−1 STZ dissolved in 0.1 M citrate buffer (pH 4.5) [15]. To confirm hyperglycemia, the blood glucose levels were measured using a SURESTEP Test Strip (Lifescan Inc., Milpitas, CA, USA) in the rats with induced DM. Changes in the systolic mechanical behavior of the ventricular pump were monitored 8 weeks after DM and CKD induction. All the rats were provided ad libitum Purina chow and water and housed under 12-h light–dark cycles. The experiments were conducted according to the Guide for the Care and Use of Laboratory Animals, and our study protocol was approved by the Animal Care and Use Committee of the National Taiwan University [28].

The cardiodynamic variables were measured in the anesthetized rats, according to previously described general surgical procedures and methods [28]. Briefly, the rats were anesthetized with sodium pentobarbital (50 mg kg−1; intraperitoneal), placed on a heating pad, intubated, and ventilated using a rodent respirator (Model 131, New England Medical Instruments, Medway, MA, USA). The chest was opened at the second intercostal space on the right side. An electromagnetic flow probe (100 series; internal circumference, 8 mm; Carolina Medical Electronics, King, NC, USA) was positioned around the ascending aorta to measure the pulsatile aortic flow. A high-fidelity pressure catheter (Model SPC 320; size, 2F; Millar Instruments, Houston, TX, USA) was inserted through the isolated right carotid artery into the left ventricle to measure the LV pressure. The electrocardiogram (ECG) of lead II was recorded using a Gould ECG/Biotach amplifier (Cleveland, OH, USA). Signals (5–10 beats at steady state) were selected on the basis of the following criteria: (1) recorded beats with optimal LV pressure and aortic velocity profiles; (2) beats with an RR interval less than 5% different from the average value for all recorded beats; and (3) exclusion of ectopic and post-ectopic beats. The selective beats were averaged in the time domain by using the peak R wave of the ECG as a fiducial point. A single-beat estimation technique was used to calculate the Emax and Qmax that characterize the systolic pumping mechanics of the heart [7].

Construction of an isovolumic pressure and a triangular flow from the measured LV pressure

The isovolumic LV pressure (Piso, Fig. 1b) can be derived from the measured LV pressure of an ejection contraction (PLV, Fig. 1a) by Eq. (1) described in Appendix 1. The estimated peak isovolumic pressure (Pisomax) is the pressure sum of the peak developed isovolumic pressure (Pidmax) and the LV end-diastolic pressure (Pd) (Fig. 1b). The uncalibrated Qtri can be constructed by using the measured LV pressure waveform demonstrated in Appendix 2. An inverse Fourier transformation of the fourth-order derivative of the LV pressure with the first 15 harmonics (Fig. 1c) was used to determine the onset, termination, and peak time points of the triangle (green curve, Fig. 1d). The Qtri scale was calibrated using the cardiac output.

Fig. 1
figure 1

Construction of the LV isovolumic pressure (Piso, b) and aortic triangular flow (Qtri, d) from the measured LV pressure waveform (PLV, a) in a CKD rat. LV, left ventricular; Pd, LV end-diastolic pressure; Pidmax, peak developed isovolumic pressure; Pisomax, peak isovolumic pressure; Qm, measured aortic flow

Calculation of the LV end-systolic elastance

The LV end-systolic elastance (Ees) can be calculated from the LV end-systolic pressure–stroke volume relationship (ESPVsR) that can be derived from the end-systolic pressure–volume relationship (ESPVR) [7, 25]. Briefly, the pressure-ejected volume loop (green curve, Fig. 2a, b) was obtained by the measured LV pressure (Fig. 1a) and the time integration of aortic flow from either Qm (black curve, Fig. 1d) or Qtri (green curve, Fig. 1d). In Fig. 2a, b, drawing a tangential line from the estimated Pisomax to the right corner of the pressure-ejected volume loop yields a point referred to as the end-systolic equilibrium point [2]. The line that connects the estimated Pisomax to the end-systolic equilibrium point is the ESPVsR, which is denoted as the red line. The slope of this red line represents the LV Ees.

Calculation of the LV maximal systolic elastance and theoretical maximum flow

The LV Emax and Qmax can be generated by using the elastance–resistance model, i.e., Eq. (2), to predict the model-derived LV pressure, which was described in Appendix 3. The signals required to fit the elastance–resistance model were the measured LV pressure, the estimated isovolumic pressure, and the aortic flow from either Qm or Qtri. The parameters (i.e., Qmax and Veed) that coincided with the minimum objective function are considered as the model estimates of the systolic pumping mechanics of the heart (green line, Fig. 2c, d). Thus, the maximal systolic elastance of the left ventricle can be computed using the relationship Emax = Pisomax / Veed; Veed is the effective LV end-diastolic volume. The maximal internal resistance of the left ventricle is expressed as Rmax = Pisomax / Qmax.

Fig. 2
figure 2

Calculation of the LV Ees and Emax from the measured PLV in the same rat, which is shown in Fig. 1. The LV EesmQ is the slope of the ESPVsR line, as derived from the measured Qm (red line, a) and the LV EestriQ from the assumed Qtri (red line, b). The elastance–resistance model is used to predict the LV pressure data using either the measured Qm (green line, c) or assumed Qtri (green line, d), generating their corresponding LV EmaxmQ and EmaxtriQ. Ees, end-systolic elastance; Emax, maximal systolic elastance; ESPVsR, end-systolic pressure–stroke volume relationship; LV, left ventricular; Qmax, theoretical maximum flow; Qm, measured aortic flow; Qtri, calibrated triangular flow; Pisomax, peak isovolumic pressure; PLV, measured LV pressure

Statistical analysis

The results are expressed as the median ± interquartile range. For comparing the effect of CKD on serum creatinine and blood urea nitrogen with that of NC, the Mann–Whitney rank-sum test was used to test for a difference between the two groups. However, the Kruskal–Wallis one-way analysis of variance (ANOVA) on ranks was performed to compare the effects of type 1 and type 2 DM on blood sugar with that of NC. The ANOVA on rank was also used to determine the statistical significance of the results for the five-group comparison on the LV pumping mechanics. Statistical significance was assumed at the level of P < 0.05. In cases where the ANOVA results indicated that a cardiodynamic variable differed significantly among groups, Dunn’s test was used to identify which group exhibited divergent median value from that of the NC group.

The simple linear regression is used to correlate the dependent variable (e.g., EmaxtriQ) with the independent variable (e.g., EmaxmQ). The linearity of the relationship is reflected in the coefficient of determination. Larger r2 value indicates that the equation is a good description of the relation between the independent and dependent variables. The smaller P value denotes the greater probability that the independent variable can be used to predict the dependent variable.

Bland–Altman plots depict the difference between the two methods of measurement on the same subjects, in which good agreement is shown by values that lie close to the 0 mean difference line and between the 95% confidence interval limits of agreement [3]. The 95% limits of agreement are estimated by mean difference ± 1.96 standard deviation of the difference.

Results

Exemplification for constructing an isovolumic pressure and a triangular flow from the measured LV pressure

Figure 1 shows the estimated isovolumic LV pressure (b) from the measured LV pressure (a) by using a non-linear least-squares approximation technique in one male CKD rat. Figure 1 also illustrates the construction of a calibrated Qtri (green curve, d) by using the filtered fourth-order derivative of the measured LV pressure (c).

Exemplification for generating the end-systolic pressure–stroke volume relationship

Figure 2 depicts the calculation of the LV Ees from the measured LV pressure in the same rat, which is shown in Fig. 1. The LV Ees is the slope of the ESPVsR line (red line, 2a and 2b), which was obtained from the measured LV pressure (1a), the estimated isovolumic pressure (1b), and the time integration of aortic flow by using either Qm (black curve, 1d) or Qtri (green curve, 1d).

Exemplification for predicting the LV pressure using the elastance–resistance model

Figure 2 also demonstrates the calculation of the LV Emax and Qmax by using the elastance–resistance model based solely on the measured PLV in the same rat, which is shown in Fig. 1. The similarity between the computed (green line, 2c and 2d) and measured (red line, 2c and 2d) pressure data obtained from the measured LV pressure, the estimated isovolumic pressure, and aortic flow either from the Qm or Qtri is apparent. The coefficient of determination and the standard error of the estimate evaluating the goodness of the model fit using Qm were 0.989 ± 0.005 and 2.247 ± 0.742%, respectively, and those from Qtri were 0.987 ± 0.004 and 2.395 ± 0.443%, respectively, when all studied rats were taken into account (n = 78).

LV E max versus LV E es in all studied rats (n = 78)

Although the LV EesmQ (453.9 ± 117.7) was greater than the LV EmaxmQ (445.7 ± 112.5), no statistical significance was found between these two indices describing the intrinsic contractile status of the heart. No significant difference was also observed between the LV EestriQ (470.9 ± 130.7) and the LV EmaxtriQ (464.3 ± 110.8).

Relation of the LV dynamic parameters obtained using Q m with those generated from Q tri

Figure 3 displays the relationship between the Qmax, Veed, and Emax calculated from the Qm (QmaxmQ, VeedmQ, and EmaxmQ, respectively, on the horizontal axes) and the Qmax, Veed, and Emax calculated from the Qtri (QmaxtriQ, VeedtriQ, and EmaxtriQ, respectively, on the vertical axes). Figure 3a displays a significant regression line for the Qmax: QmaxtriQ = 2.4053 + 0.9767 × QmaxmQ (r2 = 0.7798; P < 0.0001). Figure 3b presents the regression equation of the VeedtriQ = 0.0218 + 0.9514 × VeedmQ (r2 = 0.8611; P < 0.0001). Figure 3c illustrates the regression line between the EmaxtriQ and EmaxmQ: EmaxtriQ = 51.9133 + 0.8992 × EmaxmQ (r2 = 0.8257; P < 0.0001).

Fig. 3
figure 3

Relationship between the Qmax (a), Veed (b), and Emax (c) calculated from the measured PLV and Qm (QmaxmQ, VeedmQ, and EmaxmQ, respectively, on the horizontal axes) and the Qmax, Veed, and Emax calculated from the measured PLV and assumed Qtri (QmaxtriQ, VeedtriQ, and EmaxtriQ, respectively, on the vertical axes). Emax, maximal systolic elastance; LV, left ventricular; PLV, measured LV pressure; Qm, measured aortic flow; Qtri, calibrated triangular flow; Qmax, theoretical maximum flow; Veed, effective LV end-diastolic volume; NC, normal controls; CKD, rats with chronic kidney disease; type 1 DM, streptozotocin-induced diabetic rats; type 2 DM, streptozotocin–nicotinamide-induced diabetic rats

Figure 4 presents the Bland–Altman plot for the Qmax (a), Veed (b), and Emax (c), with mean differences of 1.5441 (mL s−1), −0.0055 (mL), and 3.0672 (mmHg mL−1), respectively.

Fig. 4
figure 4

Bland–Altman plots of the Qmax (a), Veed (b), and Emax (c). Dashed lines represent averages; dashed–dotted lines denote 95% confidence intervals. Emax, maximal systolic elastance; LV, left ventricular; Qmax, theoretical maximum flow; Veed, effective LV end-diastolic volume; NC, normal controls; CKD, rats with chronic kidney disease; type 1 DM, streptozotocin-induced diabetic rats; type 2 DM, streptozotocin–nicotinamide-induced diabetic rats

Baseline characteristics in the studied rats

Table 1 shows the baseline characteristics of the NC, CKD, and type 1 and type 2 DM groups. Compared with the NC rats, the female healthy rats had decreased body weight associated with no change in blood sugar. The rats with CKD exhibited impaired renal function, as manifested by increased levels of serum creatinine and blood urea nitrogen. No alteration in body weight was observed in the CKD group. The rats with STZ-induced type 1 DM had higher blood glucose levels associated with a decrease in body weight compared with the NC rats. Table 1 also reveals that, partially protected by NA, the STZ-NA-induced type 2 DM elicited moderate and stable hyperglycemia and prevented STZ-induced hypoinsulinemia and body weight loss.

Table 1 Baseline characteristics of NC rats, rats with CKD, and rats with either type 1 or type 2 DM

Basic hemodynamic measurements in the studied rats

Table 2 presents the basic hemodynamic measurements of the NC, CKD, and type 1 and type 2 DM groups. Compared with the NC group, the female healthy rats had a decline in cardiac output and peak isovolumic pressure, but no change in heart rate. No alterations in the heart rate, cardiac output, and peak isovolumic pressure were observed in the rats with CKD. The type 1 (but not type 2) DM group exhibited a significant reduction in heart rate. However, the type 2 (but not type 1) DM group showed a decline in cardiac output and peak isovolumic pressure.

Table 2 Basic hemodynamic data of NC rats, rats with CKD, and rats with either type 1 or type 2 DM

Effects of sex and CKD and type 1 or type 2 DM on LV pumping dynamics

Figure 5 illustrates the effects of sex and the experimental induced CKD and type 1 and type 2 DM on the systolic mechanical behavior of the ventricular pump, as derived from either the Qm or Qtri. Compared with the NC group, the female healthy group had decreased QmaxmQ and VeedmQ but showed no alteration in EmaxmQ. No statistical significant difference in QmaxmQ was found between the CKD group and the NC group. However, the CKD group showed an increase in the VeedmQ and a decrease in the EmaxmQ. The type 2 (but not type 1) DM group exhibited a significantly lower QmaxmQ than the NC group did. Both DM groups showed no alteration in the VeedmQ but showed a decline in the EmaxmQ. Meanwhile, the female healthy group, the CKD group, and both diabetic groups exhibited a difference in the QmaxtriQ, VeedtriQ, and EmaxtriQ, which showed similar statistical significance to that of their measured counterparts (i.e., QmaxmQ, VeedmQ, and EmaxmQ, respectively).

Fig. 5
figure 5

Effects of sex, CKD, and type 1 and type 2 DM on QmaxtriQ (d), VeedtriQ (e), and EmaxtriQ (f), as derived from the assumed Qtri, showed similar statistical significance to those of their measured counterparts, i.e., QmaxmQ (a), VeedmQ (b), and EmaxmQ (c), as calculated from the measured Qm. All values are expressed as the median ± interquartile range. Emax, maximal systolic elastance; LV, left ventricular; PLV, the measured LV pressure; Qm, measured aortic flow; Qtri, calibrated triangular flow; Veed, effective LV end-diastolic volume; Qmax, theoretical maximum flow; FNC, female NC; NC, normal controls; CKD, rats with chronic kidney disease; type 1 DM, streptozotocin-induced diabetic rats; type 2 DM, streptozotocin–nicotinamide-induced diabetic rats. *P < 0.05 compared with the controls

Discussion

The myocardium of the left ventricle is a viscoelastic material whose mechanical properties are reflected in the behavior of the ventricular chamber (i.e., the relationships among chamber pressure, volume, and flow). The relationship between instantaneous ventricular pressure and volume, the so-called pure elastance model, has been described in terms of a time-varying elastance [16, 24]. For an ejecting beat, the LV end-systolic elastance can be derived from the pure elastance model at the end of systole, the time at which the time-varying elastance becomes maximal [16, 23]. However, this end-systolic elastance is only an approximation to the maximal systolic elastance that is derived from isovolumic contraction, due to deactivation of myocardial shortening [6, 10, 18]. Hunter et al. [11] and Shroff et al. [17] attempted to identify the mechanical nature of the ejecting ventricle by developing models reasonably able to predict pressure–volume–flow dynamics. Campbell et al. [4] and Shroff and Motz [21] arrived at an identical configuration—a series combination of a time-varying elastance and a viscous resistance to formulate the elastance–resistance model.

Pure elastance model versus elastance–resistance model

The LV systolic elastance can be calculated from either the pure elastance model, indicated as Ees, or the elastance–resistance model, denoted as Emax. However, only the elastance–resistance model has the ability to generate the LV Qmax having an inverse relationship with the LV internal resistance. At the molecular level, the LV systolic elastance can be determined by the properties of the contractile unit along with the activation process (i.e., availability of Ca2+) and extramyocytic components [19]. However, the ventricular resistance seems to be related to the biochemical alterations of the myocardium, having an inverse relation with percent slow myosin [19].

The pure elastance model is a model-independent approach; the elastance–resistance model is a model-based approach. The major difference between these two approaches is that the original pure elastance model can accurately predict stroke volume but not instantaneous flow; for a reasonably accurate prediction of instantaneous flow, a series resistance has to be added [21]. It should be noted that the choice of a model-independent versus model-based approach clearly depends on the specific application. If the framework of an analysis involves mean values of relevant variables (e.g., stroke volume, stroke work), the pure elastance model may be appropriate [25]. If the analysis goals are such that instantaneous behavior is of significance (e.g., coupling from the perspective of pulsatile energy generated by the left ventricle, effects of arterial wave reflection), the elastance–resistance model may be more appropriate [19].

Evaluation of systolic pumping mechanics of the heart using a single LV pressure pulse

As mentioned earlier, the signals required to fit the elastance–resistance model are the simultaneously recorded LV pressure and aortic flow, followed by the isovolumic LV pressure. Obviously, the technique of measuring the isovolumic signal by occluding the ascending aorta limits its applicability in human patients. That may be the reason why a significance of the elastance–resistance model was not appreciated in a field a lot. In the present study, we proposed a technique to generate the essential signals for fitting the elastance–resistance model on the basis of the measured LV pressure alone. The first one estimated the isovolumic LV pressure from the LV pressure pulse of the ejecting beat. The second step generated a triangular flow from the measured LV pressure to approximate its corresponding aortic flow.

Construction of an isovolumic pressure and a triangular flow from the measured LV pressure

In 1980, Sunagawa et al. [26] proposed a curve-fitting technique to estimate the isovolumic LV pressure from the instantaneous pressure of an ejecting contraction (Appendix 1). They discovered that the isovolumic LV pressure and its peak value could be estimated with reasonable accuracy within the interval tej < t < tpisomax, where tej is the onset of ventricular ejection and tpisomax is the time of peak isovolumic pressure.

A triangular shape of the aortic flow wave is a reasonable assumption because the triangular approximation is consistent with the general aortic flow envelope obtained from Doppler ultrasound [30] or electromagnetic [29] flow measurements. In 2006, Westerhof et al. [29] provided a novel method for separating the measured aortic pressure wave into its forward and backward components on the basis of a single aortic pressure pulse and an assumed triangular flow. The attractiveness of their study is that calibration of the triangular flow wave derived from the measured aortic pressure is not essential in the analysis. In 2017, Wang et al. [28] proposed a method to construct an aortic triangular flow by using the measured LV pressure (Appendix 2). To investigate the cardiac contractile mechanics, the assumed triangular flow has to be calibrated with the cardiac output. In the present study, the LV pressure pulse was the only signal measured. Thus, the method proposed by Wang et al. [28] was employed to generate the Qtri for determining the systolic elastic and resistive behaviors of the heart. The similarity between the aortic flow pattern of the assumed Qtri and that of the measured Qm was demonstrated in Fig. 1d.

Restriction of the LV pressure data on the fitting interval t ej < t < t pisomax

Hunter et al. [11] have demonstrated three components in the LV response to a flow pulse; elastance, resistance, and deactivation. Without considering the deactivation factor, our model-based approach was highly dependent on the ventricular elastance and resistance. Although not perfect, the elastance–resistance model can be used to fit the measured LV pressure of an ejecting beat suitably if the fitting interval is tej < t < tpisomax (Appendix 3) [5]. That is because the deactivation component was virtually absent during early systole, became evident during mid-systole, and was most pronounced during late systole [11]. In the present study, we demonstrated that the elastance–resistance model with either the Qm or Qtri could be satisfactorily applied to measure the intrinsic LV systolic mechanics within the specified fitting interval. The LV Emax and Qmax calculated using the assumed Qtri strongly correlated with the corresponding values derived from the measured Qm (QmaxtriQ vs. QmaxmQ, Fig. 3a; EmaxtriQ vs. EmaxmQ, Fig. 3c).

Physiological meaning of the model-generated parameters for CKD and type 1 or type 2 DM

As mentioned earlier, the LV Emax was determined by the ratio of peak isovolumic pressure to the effective end-diastolic volume. Compared with the NC group, the female healthy group had diminished effective end-diastolic volume (VeedmQ, Fig. 5b; VeedtriQ, Fig. 5e) with a reduction in the peak isovolumic pressure (Table 2), resulting in no alteration in the Emax (EmaxmQ, Fig. 5c; EmaxtriQ, Fig. 5f). By contrast, a decline in Qmax (QmaxmQ, Fig. 5a; QmaxtriQ, Fig. 5d) was observed in the female healthy rats.

In the CKD group, the increased effective end-diastolic volume (VeedmQ or VeedtriQ) without any significant change in the peak isovolumic pressure contributed to a reduction in the Emax (EmaxmQ or EmaxtriQ). These results indicate that the myocardium is incapable of producing the pressure force enough to support Emax along with the increased effective end-diastolic volume. Thus, the CKD heart can be characterized as a weaker pressure generator. Although no statistical significance was found, the CKD group exhibited an increase in the Qmax (QmaxmQ or QmaxtriQ) compared with the corresponding respective values in the NC group. An increase in Qmax is indicative of a decrease in LV internal resistance, which can enhance ventricular outflow for a given cardiac contractile status and arterial load [18]. Therefore, the left ventricle of CKD can be characterized as a stronger flow generator. The opposing effects of reduced Emax and increased Qmax may negate each other, and, then, the cardiac pumping function of the CKD rats could be preserved before heart failure occurs.

In both diabetic groups, there was a trend toward decreasing peak isovolumic pressure (especially the type 2 DM) and increasing effective end-diastolic volume (VeedmQ or VeedtriQ), leading to a reduction in the Emax (EmaxmQ or EmaxtriQ). These results indicate that the myocardium cannot generate the pressure force enough to support Emax along with the increased effective end-diastolic volume. Thus, the diabetic heart can be characterized as a weaker pressure generator. A decline in Qmax (QmaxmQ or QmaxtriQ) was also observed in both diabetic groups (especially the type 2 DM). A decrease in Qmax is indicative of an increase in LV internal resistance, which can reduce ventricular outflow for a given cardiac contractile state and arterial load [18]. Therefore, the diabetic heart can be characterized as a weaker flow generator. The decreased Emax and Qmax demonstrate a deterioration in systolic pumping function of the diabetic heart. Changes in the Emax and Qmax, assessed using either the Qm or Qtri, suggested that CKD and DM could modify the systolic elastic and resistive behaviors of the left ventricle.

Limitations

Hunter et al. [11] have demonstrated that besides elastance and resistance, there are at least two or more processes involved in the description of systolic mechanical behavior of the ventricular pump. These processes may include the volume influence factor and the deactivation factor. Campbell et al. [4, 5] provided clear evidence of failings of the elastance–resistance model, especially during late systole. However, they demonstrated that the elastance–resistance model could be satisfactorily used to fit the measured LV pressure of an ejecting beat in the fitting interval tej < t < tpisomax. Although not perfect, the elastance–resistance model can provide such a succinct representation of the systolic mechanical behavior of the ventricular pump. Furthermore, Shroff et al. [20] reported that the elastance–resistance model is a useful tool to quantify the systolic pumping mechanics of the left ventricle, provided the limitations of this model are clearly understood.

Conclusions

The LV Emax and Qmax can be determined by using a minimally invasive measurement on the LV pressure. The aortic flow and isovolumic LV pressure necessary to fit the elastance–resistance model are both derived from the measured LV pressure together with cardiac output. We discovered that the estimated triangular flow can approximately calculate the LV Emax and Qmax in healthy rats and rats with CKD and type 1 or type 2 DM, and they had a strong correlation with the corresponding values derived from the measured aortic flow. The left ventricle of CKD can be characterized as a weaker pressure generator (decreased Emax) but stronger flow generator (increased Qmax). By contrast, the diabetic heart can be characterized as a weaker pressure (decreased Emax) and flow (decreased Qmax) generator. We suggest that the single-beat estimation technique is an effective method for calculating the Emax and Qmax by using a single LV pressure pulse recording together with cardiac output.

Perspectives

Although the LV pressure and aortic flow can be simultaneously measured using a high-fidelity micromanometer (such as model SVPC-664D, Millar Instruments Inc., USA) in human patients, the catheter and its associated instruments are expensive and not widely available. Moreover, the flow signal in the ascending aorta is not easy to access because of the small magnitude with noise disturbances. Although the aortic flow can non-invasively be obtained by Doppler ultrasound [30], there is difficulty in “simultaneously recording the LV pressure and aortic flow” for fitting the elastance–resistance model. In the present study, both the aortic flow and isovolumic LV pressure were derived from the only measured LV pressure together with cardiac output. In clinical settings, it is easier and safer to measure cardiac output by using non-invasive impedance cardiography [1] or echocardiography [13] to calibrate the triangular flow scale. The novelty of such an approach is that one can compute the ventricular elastance and resistance without any measurements of the ascending aortic flow wave and LV pressure from isovolumic contraction. The single-beat estimation technique can be used to investigate the cardiac pumping mechanics from solely the LV pressure of an ejection contraction obtained over a single cardiac cycle without any perturbations of the loading conditions. Thus, the practical applicability of this study is that one may evaluate the LV systolic mechanical properties in patients by using a single LV pressure measurement together with cardiac output, because the generation of the isovolumic LV pressure and Qtri and the calculation of the LV Emax and Qmax can be automatically achieved.