Abstract
Ground source heat pump is able to transform the low-grade heat energy into the high-grade heat energy through the energy stored in the soil and a small amount of power so as to make full use of all energy and alleviate environmental pollution. It is considered as a “green” system, mainly because of its use of geothermal energy, a type of renewable energy, which has enormous potential to reduce the CO2 emission as well as the fossil fuel consumption. Currently, the GSHP has integrated with many other kinds of energy technologies, such as photovoltaic generator, solar energy, thermal storage, cooling tower, and organic Rankine cycles. As for different kinds of energy technologies integrating with GSHP, the thermodynamics performance and the cycling configurations of the integrated system differ in many ways. In this chapter, all discussions about the integration of GSHP with other technologies are presented including the topics of GSHP integrated with photovoltaic generator, solar energy, thermal storage, cooling tower, as well as organic Rankine cycles, respectively. Additionally, the most typical schematic diagrams, recent developments, practical projects, and case study of some integrated system are shown in this chapter.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
ASHRAE (2011) Handbook of HVAC applications. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta
Liu X, Lu S, Hughes P, Cai Z (2015) A comparative study of the status of GSHP applications in the United States and China. Renew Sust Energ Rev 48:558–570
U.S. EPA (United States Environmental Protection Agency) Global greenhouse gas emissions data. http://www.epa.gov/climatechange/ghgemissions/global.html
Navigant Research (2013) Geothermal heat pumps residential and commercial applications for geothermal heat pumps: global market analysis and forecasts. Navigant Consulting
Ellis D (2008) Field experience with ground-source heat pumps in affordable low energy housing. In: Proceedings of ninth international energy agency heat pump conference. Zurich, 20–22 May 2008
MoHURD (2008) Guideline for evaluating demonstration projects of renewable energy applications in buildings. Ministry of Housing, Urban, and Rural Development of China, Beijing
MoHURD (2012) The 12th building energy conservation specific plan. Ministry of Housing, Urban, and Rural Development of China, Beijing
EIA (2010) Geothermal heat pump manufacturing activities 2009. US Department of Energy – US Energy Information Administration, Office of Electricity, Renewable, and Uranium Statistics. http://www.eia.gov/fuelrenewable.html
CGSB (2010) Distribution of GSHP applications in China. China Geological Survey Bureau – Shallow Geothermal Energy Research and Extension Center. www.diwenzx.org
Ozgener O, Hepbasli A (2007) A review on the energy and exergy analysis of solar assisted heat pump systems. Renew Sust Energ Rev 11:482–496
ECOFYS (2011) Financing renewable energy in the European energy market
Nykamp S, Andor M, Hurink M (2012) Standard incentive regulation hinders the integration of renewable energy generation. Energ Policy 47:222–237
Cao S, Hasan A, Siren K (2014) Matching analysis for on-site hybrid renewable energy system of office building with extended indices. Appl Energy 113:230–247
Yoza A, Yona A, Senjyu T, Funabashi T (2014) Optimal capacity and expansion planning methodology of PV and battery in smart house. Renew Energy 69:25–33
Carvalho AD, Moura P, Vaz GC, de Almeida AT (2015) Ground source heat pumps as high efficient solutions for building space conditioning and for integration in smart grids. Energy Convers Manag 103:991–1007
Safa AA, Fung AS, Kumar R (2015) Heating and cooling performance characterization of ground source heat pump system by testing and TRNSYS simulation. Renew Energy 83:565–575
Finch A, Gardner PJ, Smith AE (2016) Experimental analysis of a self-consumption strategy for residential building: the integration of PV system and geothermal heat pump. Renew Energy 86(1):343–350
Jenner S, Groba F, Indvik J (2013) Assessing the strength and effectiveness of renewable electricity feed-in tariffs in European union countries. Energ Policy 52:385–401
Antonelli M, Desideri U (2014) The doping effect of Italian feed-in tariffs on the PV market. Energ Policy 67:583–594
Cherrington R, Goodship V, Longfield A, Kirwan K (2013) The feed-in tariff in the UK: a case study focus on domestic photovoltaic systems. Renew Energy 50:421–426
Nizetic S, Coko D, Marasovic I (2014) Experimental study on a hybrid energy systems with small and medium scale application for mild climates. Energy 75:379–389
Emmi G, Zarrella A, Carli MD, Galgaro A (2015) An analysis of solar assisted ground source heat pumps in cold climates. Energy Convers Manag 106:660–675
Bi Y, Guo T, Zhang L, Chen L (2004) Solar and ground source heat-pump system. Appl Energy 78:231–245
Ozgener O, Hepbasli A (2005) Experimental performance analysis of a solar assisted ground-source heat pump greenhouse heating system. Energy Build 37:101–110
Ozgener O, Hepbasli A (2005) Performance analysis of a solar-assisted ground-source heat pump system for greenhouse heating: an experimental study. Build Environ 40:1040–1050
Berdal VT, Souyri B, Fraisse G (2006) Experimental study of a ground-coupled heat pump combined with thermal solar collectors. Energy Build 38:1477–1484
Berdal VT, Souyri B, Achard G (2007) Coupling of geothermal heat pumps with thermal solar collectors. Appl Therm Eng 27:1750–1755
Bakirci K, Ozyurt O, Comakli K, Comakli O (2011) Energy analysis of a solar-ground source heat pump system with vertical closed-loop for heating applications. Energy 36:3224–3232
Awani S, Chargui R, Kooli S, Farhat A, Guizani A (2015) Performance of the coupling of the flat plate collector and a heat pump system associated with a vertical heat exchanger for heating of the two types of greenhouses system. Energy Convers Manag 103:266–275
Kjellsson E, Hellstrom G, Perers B (2010) Optimization of systems with the combination of ground-source heat pump and solar collectors in dwellings. Energy 35:2667–2673
Reda F, Laitinen A (2015) Different strategies for long term performance of SAGSHP to match residential energy requirements in a cold climate. Energy Build 86:557–572
Kavanaugh SP, Rafferty K (1997) Ground-source heat pumps – design of geothermal system for commercial and institutional buildings. ASHRAE Applications Handbook, Atlanta
ASHRAE (2011) Chapter 34, Geothermal energy. In: ASHRAE handbook: HVAC applications. Department of Mathematical Physics and Building Technology, University of Lund
COMSOL AB, COMSOL (2008) Version 3.5, COMSOL AB, Stockholm
Yu YS, Ma ZL, Li XT (2008) A new integrated system with cooling storage in soil and ground-coupled heat pump. Appl Therm Eng 28(11–12):1450–1462
Fan R, Jiang YQ, Yao Y, Ma ZL (2008) Theoretical study on the performance of an integrated ground-source heat pump system in a whole year. Energy 33(11):1671–1679
Fan R, Jiang YQ, Yao Y, Deng SM, Ma ZL (2007) A study on the performance of a geothermal heat exchanger under coupled heat conduction and groundwater advection. Energy 32(11):2199–2209
Gan GH, Riffat SB, Chong CSA (2007) A novel rainwater–ground source heat pump – measurement and simulation. Appl Therm Eng 27(2–3):430–441
Qi YS, Yue YL, Liu TY, Yuan DL (2010) Application analysis of combined ground source heat pump and water energy storage systems. HV&AC 40(5):94–97. (in Chinese)
Yu WP, Xin CZ, Chen D (2006) Building served by a ground-source heat pump system with adit water source. HV&AC 36(6):81–83. (in Chinese)
Benli H (2011) Energetic performance analysis of a ground-source heat pump system with latent heat storage for a greenhouse heating. Energy Convers Manag 52(1):581–589
Benli H, Durmus A (2009) Evaluation of ground-source heat pump combined latent heat storage system performance in greenhouse heating. Energy Build 41(2):220–228
Wu LX, Zheng MY (2005) Research of combined heating and cooling by solar ground-source heat pump and PCM thermal storage. In: International solar energy conference, Orlando, 6–12 Aug 2005
Wang F, Liu ZL, Li ZG (2010) Numerical simulation of solar ground-source heat pump with latent heat storage. In: International conference on material and manufacturing technology, Chongqing,17–19 Sept 2010
Dehdezi PK, Hall MR, Dawson AR (2011) Enhancement of soil thermo-physical properties using microencapsulated phase change materials for GSHP applications. In: Second international conference on mechanical and aerospace engineering (ICMAE 2011), Bangkok, 29–31 Jul 2011
Kaygusuz K (1999) Investigation of a combined solar heat pump system for residential heating, part 1: experimental results. Int J Energy Res 23(14):1213–1223
Kaygusuz K (1999) Investigation of a combined solar heat pump system for residential heating, part 2: simulation results. Int J Energy Res 23(14):1225–1237
Zhu N, Hu P, Xu L, Jiang Z, Lei F (2014) Recent research and applications of ground source heat pump integrated with thermal energy storage systems: a review. Appl Therm Eng 71:142–151
Barbier E (2002) Geothermal energy technology and current status: an overview. Renew Sust Energ Rev 6:3–65
DiPippo R (2008) Geothermal power plants: principles, applications case studies and environmental impact. Butterworth-Heinemann, Oxford
Lund JW (2006) Geothermal energy focus: tapping the earth’s natural heat. Refocus 7(6):48–51
Bertani R (2005) World geothermal power generation in the period 2001–2005. Geothermics 34:651–690
Lund JW (2004) 100 Years of geothermal power production. GHC Bulletin
Bronicki LY (1988) Electrical power from moderated temperature geothermal sources with modular mini-power plants. Geothermics 17:83–92
Bronicki LY (2007) Organic rankine cycles in geothermal power plants – 25 years of ORMAT experience. In: GRC annual meeting, Reno
Brasz JJ, Biederman BP, Holdmann G (2005) Power production from a moderate temperature – geothermal resource. In: GRC annual meeting, Reno
Aneke M, Agnew B, Underwood C (2011) Performance analysis of the Chena binary geothermal power plant. Appl Therm Eng 31:1825–1832
Chena Power LLC (2007) 400 kW geothermal power plant at Chena hot springs. Final report for Alaska Energy Authority, Alaska
Smith IK, Stosic N (2001) Prospects for energy conversion efficiency improvements by the use of twin screw two-phase expanders. In: Second international heat powered cycles conference, Paris
Smith IK, Stosic N, Kovacevic A (2001) Power recovery from low cost two-phase expanders. In: GRC annual meeting, San Diego
Smith IK, Stosic N, Kovacevic A (2005) Screw expanders increase output and decrease the cost of geothermal binary power plant systems. In: Geothermal resources council annual meeting, Reno, 25–28 Sept 2005
Electratherm. http://www.electratherm.com/
BEP Europe. http://www.bepenergy.com/
DiPippo R (2004) Second law assessment of binary plants generating power from low-temperature geothermal fluids. Geothermics 33:565–586
Franco A, Villani M (2009) Optimal design of binary cycle power plants for water-dominated, medium-temperature geothermal fields. Geothermics 38:379–391
Borsukiewicz-Gozdur A, Nowak W (2007) Maximising the working fluid flow as a way of increasing power output of geothermal power plant. Appl Therm Eng 27:2074–2078
Kanoglu M, Bolatturk A (2008) Performance and parametric investigation of a binary geothermal power plant by exergy. Renew Energy 33:2366–2374
Heberle F, Bruggemann D (2010) Exergy based fluid selection for a geothermal organic Rankine cycle for combined heat and power generation. Appl Therm Eng 30:1326–1332
Gawlik K, Hassani V (1998) Advanced binary cycles: optimum working fluids. In: Geothermal resources council annual meeting, San Diego, 20–23 Sept 1998
Madhawa Hettiarachchi HD, Golubovic M, Worek WM, Ikegami Y (2007) Optimum design criteria for an organic Rankine cycle using low-temperature geothermal heat sources. Energy 32:1698–1706
Guo T, Wang HX, Zhang SJ (2011) Fluids and parameters optimization for a novel cogeneration system driven by low-temperature geothermal sources. Energy 36:2639–2649
Shengjun Z, Huaixin W, Tao G (2011) Performance comparison and parametric optimization of subcritical organic Rankine cycle (ORC) and transcritical power cycle system for low-temperature geothermal power generation. Appl Energy 88:2740–2754
ASHRAE (1995) Commercial/institutional ground-source heat pump engineering manual. ASHRAE, Inc., Atlanta
Kavanaugh SP, Rafferty K (1997) Ground-source heat pumps: design of geothermal systems for commercial and institutional buildings. ASHREA, Atlanta
Kavanaugh SP (1998) A design method for hybrid ground source heat pumps. ASHRAE Trans 104(2):691–698
Qi Z, Gao Q, Liu Y, Yan Y, Spitler J (2014) Status and development of hybrid energy systems from hybrid ground source heat pump in China and other countries. Renew Sust Energ Rev 29:37–51
Chiasson AD, Yavuzturk CC, Johnson DW, Filburn TP (2010) Optimization of the ground thermal response in hybrid geothermal heat pump systems. ASHRAE Trans 116:512–524
Ni L, Song W, Zeng F, Yao Y (2011) Energy saving and economic analyses of design heating load ratio of ground source heat pumps with gas boiler as auxiliary heat source. In: Conference on electric technology and civil engineering (ICETCE), Lushan, pp 1197–1200
Yavuzturk C, Spitler JD (1999) A short time step response factor model for vertical ground-loop heat exchangers. ASHRAE Trans 105(2):475–485
Yavuzturk C, Spitler JD (2000) Comparative study to investigate operating and control strategies for hybrid ground source heat pump systems using a short time-step simulation model. ASHRAE Trans 106(2):192–209
Ramamoorthy M, Jin H, Chiasson A, Spitler JD (2001) Optimal sizing of hybrid ground-source heat pump systems that use a cooling pond as a supplemental heat rejecter – a system simulation approach. ASHRAE Trans 107(1):26–38
Wrobel J (2004) Predictive model and application of a hybrid GSHP system for space conditioning, water heating and deicing of a seniors independent living center. In: Proceedings of 2004 ASME international mechanical engineering congress and exposition, Anaheim
Hackel SP (2008) Development of design guidelines for hybrid ground-coupled heat pump systems. ASHRAE TRP-1384 final report. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta
Man Y, Yang H, Fang Z (2008) Study on hybrid ground-coupled heat pump systems. Energy Build 40:2028–2036
Gang W, Wang J, Wang S (2014) Performance analysis of hybrid ground source heat pump systems based on ANN predictive control. Appl Energy 136:1138–1144
Mokhtara M, Stables M, Liu X, Howe J (2013) Intelligent multi-agent system for building heat distribution control with combined gas boilers and ground source heat pump. Energy Build 62:615–626
Bin H, Li Y, Baojie M et al (2016) Extremum seeking control for efficient operation of hybrid ground source heat pump system. Renew Energy 86:332–346
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Section Editor information
Rights and permissions
Copyright information
© 2018 Springer-Verlag GmbH Germany, part of Springer Nature
About this entry
Cite this entry
Hu, B. (2018). Integration of Ground Source Heat Pump with Other Technologies. In: Wang, R., Zhai, X. (eds) Handbook of Energy Systems in Green Buildings. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-49120-1_27
Download citation
DOI: https://doi.org/10.1007/978-3-662-49120-1_27
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-662-49119-5
Online ISBN: 978-3-662-49120-1
eBook Packages: EnergyReference Module Computer Science and Engineering