Skip to main content

Table 1 The characteristics of various boilers

From: Prime Movers

Types

pulverized coal furnace

grate boiler

spreader stoker

furnace in fluid bed

circulating fluidized bed boiler

cyclone furnace

Chemical incomplete combustion loss (%)

0

<2

<1

≈0

≈0

0

Mechanical incomplete combustion loss (%)

2–4

5–15

6–12

5–30

2–4

≈0

Thermal efficiency of boiler (%)

More than 85

70–82

70–82

65–72

More than 85

More than 85

Rated evaporation (t/h)

≥35

≤35

≤35

≤35

≥35

≥75

Applicable coal type

Anthracite, bituminous coal, lean coal and lignite

II, III anthracite, II, III soft coal, meagre coal

III anthracite, II,III soft coal, meagre coal, bagasse

Stone coal, lignite coal gangue

Anthracite, soft coal, meagre coal, lignite coal

Soft coal, anthracite, meagre coal

Load variation adaptability

Can work stably when the rated evaporation is 70%

Can work stably at 50% of rated evaporation, load changes slowly

Variation range of evaporation is extensive, load changes rapidly

Variation range of evaporation is extensive, load changes quickly

Variation range of evaporation is larger, load changes rapidly

Load adjustment range is small, cannot quickly start and stop

  1. Small and medium sized cogeneration engineering design manual 2006