Abstract
High-voltage dielectric withstand performance testing with equipment utilizes the phenomena in electrical insulation under the influence of electric fields changing with the power frequency. When electrical insulation is stressed in an electric field, ionization may cause electrical discharges initiating from one electrode of high potential to the one of low potential or vice versa. It may also cause a high current rise and lose the dielectric withstand capability to separate different potentials of the equipment.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Achatz, N., et al.: Features and benefits of UHF partial discharge monitoring systems for GIS. In: ISEIM, Kitakyushu (2005)
CIGRE TF D1.03.09: Risk assessment on defects in GIS based on PD diagnostics
CIGRE WG A3.06: Final report of the 2004–2007 international enquiry on reliability of high voltage equipment, part 2 – reliability of high voltage SF6 circuit breaker, CIGRE technical brochure no. 510 (2012)
Diessner, A., Luxa, G., Neyer, W.: Electrical aging tests on epoxy insulators in GIS. IEEE Trans. Elec. Ins. 24(2), 277–283 (1989)
Hampton, B.F.: UHF diagnostics for gas insulated substations
Hauschild, W., Lemke, E.: High Voltage Test and Measuring Techniques. Springer, Berlin/Heidelberg (2014)
Holaus, W., et al.: Development and testing of 1100 kV GIS. In: CIGRE/IEC UHV Symposium
IEC 60060-1: High voltage test techniques
IEC 62271-203: High-voltage switchgear and controlgear – part 203 Gas-insulated metal enclosed switchgear for rated voltages above 52 kV (2003)
Juhre, K., Kynast, E.: Long term performance under high voltage of mineralic filled and fiber reinforced epoxy insulators used in GIS. In: 14th ISH, Beijing (2005)
Kuffel, E., Zaengl, W.S.: High Voltage Engineering Fundamentals. Pergamon Press, Oxford. ISBN 0-08-024213-8 (1984)
Kuschel, M., Laskowski, K.: Economic aspects of online monitoring of GIS based on life cycle cost analysis. In: 14th ISH, Beijing (2005)
Neumann, C., et al.: The impact of insulation monitoring and diagnostics on reliability and exploitation of service life. CIGRE report C4–201, session 2006, Paris (2006)
Schichler, U., Gorablenkow, J., Diessner, A.: UHF PD detection in GIS substations during on-site testing. In: DMMA, Edinburgh (2000)
Simka, P.: Dielectric coordination of high voltage gas circuit breakers, PhD Thesis, ETH Zurich
Tests and measurements in the life cycle of high voltage equipment, HV Colloquium (2007)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer International Publishing AG, part of Springer Nature
About this entry
Cite this entry
Le Roux, R., Minagawa, T. (2019). Dielectric Withstand Performance Tests. In: Ito, H. (eds) Switching Equipment. CIGRE Green Books. Springer, Cham. https://doi.org/10.1007/978-3-319-72538-3_10
Download citation
DOI: https://doi.org/10.1007/978-3-319-72538-3_10
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-72537-6
Online ISBN: 978-3-319-72538-3
eBook Packages: EngineeringReference Module Computer Science and Engineering