The Use of Kinematics for Pulmonary Volume Assessment

Reference work entry

Abstract

Since the movements of the lung are transmitted to the chest wall during breathing, the interest in technologies for the noninvasive monitoring of the kinematics of the thorax to study the breathing biomechanics is growing up. The analysis of the kinematics of the chest wall can be used to: (i) measure human chest wall movements, (ii) study the mechanics of breathing, and (iii) evaluate respiratory volumes during breathing. Differently from the spirometer and other equipment, tools based on the tracking of the chest wall deformities allow patients to perform breathing exercises without any kind of constraints and to investigate the unaltered breathing mechanics, as well as to separately study the behavior of each compartment of the chest wall.

The most well-established technology to assess the breathing volume of the chest wall and of its compartments (i.e., pulmonary and abdominal rib cage and abdomen) is the optoelectronic plethysmography (OEP). OEP is a motion capture system designed and validated to track a number of photo-reflective markers placed on the human chest wall. By the reconstruction of the kinematics of the chest, OEP algorithm allows the computation of the subject’s respiratory volumes and other breathing-related features.

Since 1990 a lot of research group have been developed and tested non-invasive optical technologies to assess respiratory pattern parameters, to measure asynchronies inside chest wall, to investigate patient respiratory strategies and volume moved, and to distinguish different respiratory disease. Specifically, the increasing use of OEP in clinical evaluation context in the respiratory field is widely proven by the growing number of published articles in the last few years.

Its noninvasiveness and the possibility of the use of other equipment (e.g., pressure sensors, electromyography, electrocardiogram) and devices (e.g., cycle ergometer, treadmill) at the same time allow to study a wide range of patients with different physiological and clinical condition (included the no-collaborative ones) and provide new perspective on the evaluation of ventilatory parameters.

Keywords

Breathing Respiratory volumes Breathing mechanics Chest wall kinematics Lung volumes 

References

  1. Aliverti A et al (2001) Compartmental analysis of breathing in the supine and prone positions by optoelectronic plethysmography. Ann Biomed Eng 29(1):60–70. Available at: http://link.springer.com/10.1114/1.1332084. Accessed 24 Sept 2014CrossRefGoogle Scholar
  2. Aliverti A, Stevenson N, Dellacà RL, et al (2004) Regional chest wall volumes during exercise in chronic obstructive pulmonary disease. Thorax 59:210–216Google Scholar
  3. Aliverti A et al (2005) Effect of salbutamol on lung function and chest wall volumes at rest and during exercise in COPD. Thorax 60(11):916–924. Available at: http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=1747234&tool=pmcentrez&rendertype=abstract. Accessed 24 Sept 2014CrossRefGoogle Scholar
  4. Aliverti A et al (2009) Paradoxical movement of the lower ribcage at rest and during exercise in COPD patients. Eur Respir J 33(1):49–60. Available at: http://www.ncbi.nlm.nih.gov/pubmed/18799505. Accessed 24 Sept 2014CrossRefGoogle Scholar
  5. Aliverti A et al (2015) Optoelectronic plethysmography. In: Springer-Verlag (ed) Mechanics of breathing pathophysiology, diagnosis, and treatment. Springer-Verlag, MilanoGoogle Scholar
  6. Barnas GM et al (1987) Impedance and relative displacements of relaxed chest wall up to 4 Hz. J Appl Physiol (Bethesda, Md.: 1985) 62:71–81CrossRefGoogle Scholar
  7. Bastianini F, Silvestri S, Magrone G, Gallotta E, Sterzi S (2009) A preliminary efficacy evaluation performed by opto-electronic plethysmography of asymmetric respiratory rehabilitation. In 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 849–852Google Scholar
  8. Bruni GI et al (2012) Dyspnea, chest wall hyperinflation, and rib cage distortion in exercising patients with chronic obstructive pulmonary disease. Med Sci Sports Exerc 44:1049–1056Google Scholar
  9. Cala SJ et al (1996) Chest wall and lung volume estimation by optical reflectance motion analysis. J Appl Physiol (Bethesda, Md.: 1985) 81:2680–2689CrossRefGoogle Scholar
  10. Chen L et al (1994) An investigation on the accuracy of 3-dimensional space reconstruction using the direct linear transformation technique. J Biomech 27:493–500CrossRefGoogle Scholar
  11. Chiumello D et al (2007) Effects of volume shift on the pressure-volume curve of the respiratory system in ALI/ARDS patients. Minerva Anestesiol 73(3):109–118. Available at: http://www.scopus.com/inward/record.url?eid=2-s2.0-34248997789&partnerID=tZOtx3y1. Accessed 24 Sept 2014Google Scholar
  12. D’Angelo MG et al (2009) M.P.2.05 Optoelectronic plethysmography in respiratory assessment in Duchenne muscular dystrophy. Neuromuscul Disord 19(8–9):572–572. Available at: http://www.sciencedirect.com/science/article/pii/S0960896609002508. Accessed 24 Sept 2014MathSciNetCrossRefGoogle Scholar
  13. D’Angelo MG et al (2011) Respiratory pattern in an adult population of dystrophic patients. J Neurol Sci 306(1–2):54–61. Available at: http://www.sciencedirect.com/science/article/pii/S0022510X1100178X. Accessed 24 Sept 2014CrossRefGoogle Scholar
  14. Dellaca RRL et al (2010) Measurement of total and compartmental lung volume changes in newborns by optoelectronic plethysmography. Pediatr Res 67(1):11–16. Available at: http://www.ncbi.nlm.nih.gov/pubmed/19755932. Accessed 24 Sept 2014CrossRefGoogle Scholar
  15. Ferrigno G, Pedotti A (1985) ELITE: a digital dedicated hardware system for movement analysis via real-time TV signal processing. IEEE Trans Biomed Eng 32(11):943–950. Available at: http://www.ncbi.nlm.nih.gov/pubmed/3905583. Accessed 20 Feb 2015CrossRefGoogle Scholar
  16. Ferrigno G et al (1994) Three-dimensional optical analysis of chest wall motion. J Appl Physiol 77:1224–1231CrossRefGoogle Scholar
  17. Gagliardi E, Bruni G, Presi I (2014) Thoraco-abdominal motion/displacement does not affect dyspnea following exercise training in COPD patients. Respir Physiol Neurobiol 190:124–130Google Scholar
  18. Georgiadou O et al (2007) Effects of rehabilitation on chest wall volume regulation during exercise in COPD patients. Eur Respir J 29(2):284–291. Available at: http://www.scopus.com/inward/record.url?eid=2-s2.0-33846926545&partnerID=tZOtx3y1. Accessed 21 Sept 2014CrossRefGoogle Scholar
  19. Konno K, Mead J (1967) Measurement of the separate volume changes of rib cage and abdomen during breathing. J Appl Physiol 22(3):407–422CrossRefGoogle Scholar
  20. Levai IK et al (2017) Optoelectronic plethysmography (OEP) in the assessment of dysfunctional breathing (DB) in athletes. Eur Respir J 48 (suppl 60)Google Scholar
  21. Lissoni A et al (1996) Spinal muscular atrophy: kinematic breathing analysis. Am J Phys Med Rehabil 75(5):332–339. Available at: http://search.ebscohost.com/login.aspx?direct=true&db=cin20&AN=1997019718&site=ehost-liveCrossRefGoogle Scholar
  22. Lo Mauro A et al (2010) Abdominal volume contribution to tidal volume as an early indicator of respiratory impairment in Duchenne muscular dystrophy. Eur Respir J 35(5):1118–1125. Available at: http://www.scopus.com/inward/record.url?eid=2-s2.0-77951970331&partnerID=tZOtx3y1. Accessed 24 Sept 2014CrossRefGoogle Scholar
  23. Massaroni C et al (2015a) Evaluation of optoelectronic plethysmography accuracy and precision in recording displacements during quiet breathing simulation. In 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp 1291–1294. Available at: http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=7318604. Accessed 21 Jan 2016
  24. Massaroni C, Saccomandi P, Schena E (2015b) Medical smart textiles based on fiber optic technology: an overview. J Funct Biomater 6(2):204–221Google Scholar
  25. Massaroni C et al (2016a) Breathing analysis during exercise: comparison between optoelectronic system and breath-by breath analyzer. In European Society of Biomechanics (ESB). Available at: https://scholar.google.it/citations?view_op=view_citation&hl=it&user=jEHMd9kAAAAJ&sortby=pubdate&citation_for_view=jEHMd9kAAAAJ:L8Ckcad2t8MC
  26. Massaroni C et al (2016b) Optical measurement of breathing: algorithm volume calibration and preliminary validation on healthy trained subjects. In 38th annual international conference of the IEEE engineering in medicine and biology society, pp 2153–2156Google Scholar
  27. Massaroni C, Saccomandi P, Formica D, Lo Presti D, Caponero MA, Di Tomaso G, Giurazza F, Muto M, Schena E (2016c) Design and feasibility assessment of a magnetic resonance-compatible smart textile based on fiber Bragg grating sensors for respiratory monitoring. IEEE Sens J 16(22):8103–8110Google Scholar
  28. Massaroni C, Cassetta E, Silvestri S (2017) A novel method to compute breathing volumes via motion capture systems: design and experimental trials. J Appl Biomech (in press). http://www.ncbi.nlm.nih.gov/pubmed/28338381
  29. Mead J (1963) The control of respiratory frequency. Ann N Y Acad Sci 109:724–729CrossRefGoogle Scholar
  30. Mead J et al (1967) Pulmonary ventilation measured from body surface movementsGoogle Scholar
  31. Millard RK (1999) Inductive plethysmography components analysis and improved non-invasive postoperative apnoea monitoring. Physiol Meas 20:175–186CrossRefGoogle Scholar
  32. Muniz de Souza H et al (2016) Acute effects of different inspiratory efforts on ventilatory pattern and chest wall compartmental distribution in elderly women. Respir Physiol Neurobiol 227:27–33. Available at: http://www.sciencedirect.com/science/article/pii/S1569904816300118. Accessed 20 Mar 2016CrossRefGoogle Scholar
  33. Parreira VF et al (2012) Optoelectronic plethysmography: a review of the literature. Rev Bras Fisioter 16(6):439–453. Available at: http://www.ncbi.nlm.nih.gov/pubmed/23184278. Accessed 24 Sept 2014CrossRefGoogle Scholar
  34. Romagnoli I et al (2008) Optoelectronic plethysmography has improved our knowledge of respiratory physiology and pathophysiology. Sensors 8(12):7951–7972. Available at: http://www.scopus.com/inward/record.url?eid=2-s2.0-58149203421&partnerID=tZOtx3y1. Accessed 24 Sept 2014CrossRefGoogle Scholar
  35. Romei M et al (2010) Effects of gender and posture on thoraco-abdominal kinematics during quiet breathing in healthy adults. Respir Physiol Neurobiol 172(3):184–191. Available at: http://www.ncbi.nlm.nih.gov/pubmed/20510388. Accessed 24 Sept 2014CrossRefGoogle Scholar
  36. Vieira DSR et al (2013) Optoelectronic plethysmography: intra-rater and inter-rater reliability in healthy subjects. Respir Physiol Neurobiol 189(3):473–476. Available at: http://www.ncbi.nlm.nih.gov/pubmed/24036178. Accessed 24 Sept 2014CrossRefGoogle Scholar
  37. Wilhelm FH, Roth WT, Sackner MA (2003) The Life Shirt. Behav Modif 27(5):671–691Google Scholar

Copyright information

© Springer International Publishing AG, part of Springer Nature 2018

Authors and Affiliations

  1. 1.Unit of Measurements and Biomedical InstrumentationCampus Bio-Medico di Roma UniversityRomeItaly

Section editors and affiliations

  • Freeman Miller
    • 1
  1. 1.duPont Hospital for ChildrenWilmingtonUSA

Personalised recommendations