Encyclopedia of Computational Neuroscience

Living Edition
| Editors: Dieter Jaeger, Ranu Jung

Neuromorphic Sensors, Cochlea

Living reference work entry
DOI: https://doi.org/10.1007/978-1-4614-7320-6_118-1

Synonyms

Definition

The biological cochlea is a bony, fluid-filled structure in the inner ear. It performs the transduction between the pressure signal representing the acoustic input and the neural signals that carry information to the brain. The cochlea is spiraled from the base to the apex, containing approximately 2.5 turns. The internal part of the cochlea is divided into three chambers (scalae): scala vestibuli, scala media, and scala tympani; Reissner’s membrane separates the first chamber from the second chamber, and the basilar membrane (BM) separates the second and third chambers. A specialized structure, the organ of Corti, sits atop the basilar membrane. It contains both the inner and outer hair cells (IHCs and OHCs, respectively). The tips of these cells have hairlike structures, called stereocilia. Deflections in the stereocilia of the IHCs generate neural signals that travel to the brain. Neural...

Keywords

Corti 
This is a preview of subscription content, log in to check access

References

  1. Abdalla H, Horiuchi TK (2005) An ultrasonic filterbank with spiking neurons. IEEE Int Symp Circuits Syst 5:4201–4204Google Scholar
  2. Abdalla H, Horiuchi TK (2008) Binaural spectral cues for ultrasonic localization. IEEE Int Symp Circuits Syst 2110–2113Google Scholar
  3. Abdollahi M, Liu S-C (2011) Speaker-independent isolated digit recognition using an AER silicon cochlea. Biomed Circuits Syst Conf 269–272Google Scholar
  4. Baker MW, Sarpeshkar R (2003) A low-power high-PSRR current-mode microphone preamplifier. IEEE J Solid-State Circuits 38:1671–1678CrossRefGoogle Scholar
  5. Chakrabartty S, Liu S-C (2010) Exploiting spike-based dynamics in a silicon cochlea for speaker identification. IEEE Int Symp Circuits Syst 513–516Google Scholar
  6. Chan V, Liu S-C, van Schaik A (2007) AER EAR: a matched silicon cochlea pair with address event representation interface. IEEE Trans Circuits Syst I Regul Pap 54:48–59CrossRefGoogle Scholar
  7. Chan V, Jin C, van Schaik A (2010) Adaptive sound localization with a silicon cochlea pair. Front Neurosci 4(196):1–11, doi:10.3389/fnins.2010.00196Google Scholar
  8. Delbruck T (2007) jAER open source project. Available http://jaerproject.net
  9. Delbruck T, Lichtsteiner P (2006) Fully programmable bias current generator with 24 bit resolution per bias. IEEE Int Symp Circuits Syst:2849–2852Google Scholar
  10. Finger H, Liu S-C (2011) Estimating the location of a sound source with a spike-timing localization algorithm. IEEE Int Symp Circuits Syst 2461–2464Google Scholar
  11. Fragniere E (2005) A 100-channel analog CMOS auditory filter bank for speech recognition. ISSCC Dig Tech Pap 140–589Google Scholar
  12. Georgiou J, Toumazou C (2005) A 126-uW cochlear chip for a totally implantable system. IEEE J Solid-State Circuits 40:430–443CrossRefGoogle Scholar
  13. Hamilton T, Jin C, van Schaik A, Tapson J (2008) An active 2-D silicon cochlea. IEEE Trans Biomed Circuits Syst 2:30–43PubMedCrossRefGoogle Scholar
  14. Katsiamis A, Drakakis E, Lyon R (2009) A 4.5uW, 120 + dB, log-domain cochlea channel with AGC. IEEE J Solid-State Circuits 44:1006–1022CrossRefGoogle Scholar
  15. Kumar N, Himmelbauer W, Cauwenberghs G, Andreou A (1998) An analog VLSI chip with asynchronous interface for auditory feature extraction. IEEE Trans Circuits Syst II 45:600–606CrossRefGoogle Scholar
  16. Lazzaro J, Wawrzynek J, Mahowald M, Sivilotti S, Gillespie D (1993) Silicon auditory processors as computer peripherals. IEEE Trans Neural Netw 4:523–528PubMedCrossRefGoogle Scholar
  17. Li C-H, Delbruck T, Liu S-C (2012) Real-time speaker identification using the AEREAR2 event-based silicon cochlea. IEEE Int Symp Circuits Syst 1159–1162Google Scholar
  18. Liu S-C, Delbruck T (2010) Neuromorphic sensory systems. Curr Opin Neurobiol 20:1–8CrossRefGoogle Scholar
  19. Liu S-C, van Schaik A, Minch B, Delbrück T (2010) Event-based 64-channel binaural silicon cochlea with Q enhancement mechanisms. IEEE Int Symp Circuits Syst 2027–2030Google Scholar
  20. Liu S-C, Mesgarani N, Harris J, Hermansky H (2010) The use of spike-based representations for hardware audition systems. IEEE Int Symp Circuits Syst 505–508Google Scholar
  21. Lyon RF, Mead C (1988) An analog electronic cochlea. IEEE Trans Acoust Speech Signal Process 36:1119–1134CrossRefGoogle Scholar
  22. Palmer AR, Russell IJ (1986) Phase-locking in the cochlear nerve of the guinea-pig and its relation to the receptor potential of inner hair-cells. Hear Res 24:1–15PubMedCrossRefGoogle Scholar
  23. Sarpeshkar R, Lyon RF, Mead C (1998) A low-power wide-dynamic-range analog VLSI cochlea. Analog Integr Circuits Signal Process 16:245–274CrossRefGoogle Scholar
  24. Sarpeshkar R, Salthouse C, Sit JJ, Baker M, Zhak S, Lu T, Turicchia L, Balster S (2005) An ultra-low-power programmable analog bionic ear processor. IEEE Trans Biomed Eng 2:711–727CrossRefGoogle Scholar
  25. Shamma S (1985) Speech processing in the auditory system I: the representation of speech sounds in the responses of the auditory nerve. J Acoust Soc Am 78:1612–1621PubMedCrossRefGoogle Scholar
  26. van Schaik A, Fragnière E, Vittoz E (1996) Improved silicon cochlea using compatible lateral bipolar transistors. Adv Neural Inf Process Syst 8:671–677Google Scholar
  27. Watts L, Kerns D, Lyon R, Mead C (1992) Improved implementation of the silicon cochlea. IEEE J Solid State Circuits 27:692–700CrossRefGoogle Scholar
  28. Wen B, Boahen K (2006) A 360-channel speech preprocessor that emulates the cochlear amplifier. ISSCC Dig Tech Pap 556–557Google Scholar
  29. Wen B, Boahen K (2009) A silicon cochlea with active coupling. IEEE Trans Biomed Circuits Syst 3:444–455CrossRefGoogle Scholar

Copyright information

© Springer Science+Business Media New York 2014

Authors and Affiliations

  1. 1.University of Zurich and ETH ZurichZurichSwitzerland
  2. 2.University of Western SydneyPenrithAustralia