Advertisement

White Light Interferometry

  • Joanna Schmit
  • Anna PakułaEmail author
Reference work entry

Abstract

White light interferometry is a well-known measurement technique commonly used in 3D shape and roughness characterization of engineered and biological objects. In this chapter, the theoretical background of two beam interference is first given. This section highlights the basics of interference, its dependence on temporal and spatial coherence of the source, and how coherence is used in different types of measurement. Next, the basics of fringe formation is discussed, followed by a description of the most common white light interference analysis methods. Frequently used and commercially available white light interferometry systems based on microscopes with interference objectives, namely Michelson, Mirau, and Linnik, are discussed, followed by a description of setups built specially to adapt to chosen sample geometries – as large complex samples, flats or cylinders, immersed objects, and matrixes of small samples. Next is a discussion of the analysis of white light fringes used to measure special features of objects, i.e., thick and thin films, harmonically moving objects, involving surface features that are challenging to measure (dissimilar materials, complicated geometry, etc.). A special case of white light interferometric system that is combined with a spectrometer is also briefly described. Finally, common applications of white light interferometry, those where the technique is used directly or those in which the white light signal is auxiliary, are briefly described.

References

  1. Abdulhalim I (2001) Theory for double beam interference microscopes with coherence effects and verification using the linnik microscope. J Mod Opt 48:279–302.  https://doi.org/10.1080/09500340108232458CrossRefzbMATHGoogle Scholar
  2. Abdulhalim I (2006) Competence between spatial and temporal coherence in full field optical coherence tomography and interference microscopy. J Opt A Pure Appl Opt 8:952.  https://doi.org/10.1088/1464-4258/8/11/004CrossRefGoogle Scholar
  3. Abdulhalim I (2012) Spatial and temporal coherence effects in interference microscopy and full-field optical coherence tomography. Ann Phys 524:787–804.  https://doi.org/10.1080/09500340108232458CrossRefGoogle Scholar
  4. Ai C, Caber PJ (1994) Combination of white-light scanning and phase-shifting interferometry for surface profile measurements. US Patent US 5471303A. https://patents.google.com/patent/US5471303A/en. Accessed 20 Jun 2018
  5. Albertazzi AG Jr, Dal Pont A (2005) Fast coherence scanning interferometry for smooth, rough and spherical surfaces. Fringe 2005:605–612Google Scholar
  6. Albertazzi AG, Viotti MR, Miggiorin RM, Dal Pont A (2008) Applications of a white light interferometer for wear measurement of cylinders. Proc SPIE 7064:70640B.  https://doi.org/10.1117/12.796058CrossRefGoogle Scholar
  7. Balasubramanian N (1982) Optical system for surface topography measurement. US Patent 4,340,306Google Scholar
  8. Baryshev SV, Zinovev AV, Tripa CE, Erck RA, Veryovkin IV (2012) White light interferometry for quantitative surface characterization in ion sputtering experiments. Appl Surf Sci 258:6963–6968.  https://doi.org/10.1016/j.apsusc.2012.03.144CrossRefGoogle Scholar
  9. Bauer W (2003) Special properties of coherence scanning interferometers for large measurement volumes. J Phys Conf Ser 311:012030.  https://doi.org/10.1088/1742-6596/311/1/012030CrossRefGoogle Scholar
  10. Beverage JL, de Lega XC, Fay MF (2014) Interferometric microscope with true color imaging. SPIE Proc 9203:92030S.  https://doi.org/10.1117/12.2063264CrossRefGoogle Scholar
  11. Berwal S, Srivastava V, Dubey VK, Ahmad A, Mehta DS, md. Inam (2014) High-resolution white light interferometry for quantitative phase imaging of human red blood cells using three-chip colour camera. International conference on fibre optics and photonics:M4A.6.  https://doi.org/10.1364/PHOTONICS.2014.M4A.6
  12. Bosseboeuf A, Petitgrand S (2003) Characterization of the static and dynamic behaviour of M(O)EMS by optical techniques: status and trends. J Micromech Microeng 13:S23–S33.  https://doi.org/10.1088/0960-1317/13/4/304CrossRefGoogle Scholar
  13. Bouchal P, Čelechovský R, Bouchal Z (2015) Polarization sensitive phase-shifting Mirau interferometry using a liquid crystal variable retarder. Opt Lett 40:4567.  https://doi.org/10.1364/OL.40.004567CrossRefzbMATHGoogle Scholar
  14. Brann M, Suter JD, Addleman RS, Larimer C (2017) Monitoring bacterial biofilms with a microfluidic flow chip designed for imaging with white-light interferometry. Biomicrofluidics 11:044113.  https://doi.org/10.1063/1.4985773CrossRefGoogle Scholar
  15. Brinkmann S, Bodschwinna H, Lemke H-W (2000) Development of robust Gaussian regression filter for three dimensional surface analysis. Proceedings of the 10th international colloquium on surfaces, Chemnitz, GermanyGoogle Scholar
  16. Cai Y, Dong Y, Hoenders BJ (2012) Interdependence between the temporal and spatial longitudinal and transverse degrees of partial coherence and a generalization of the van Cittert–Zernike theorem. J Opt Soc Am A 29:2542–2551.  https://doi.org/10.1364/JOSAA.29.002542CrossRefGoogle Scholar
  17. Caber PJ (1993) Interferometric profiler for rough surfaces. Appl Opt 32:3438–3441.  https://doi.org/10.1364/AO.32.003438CrossRefGoogle Scholar
  18. Chen D (2006) High-definition vertical-scan interferometry. US Patent US7605925B1Google Scholar
  19. Chen L-C, Huang Y-T, Nguyen X-L, Chen J-L, Chang C-C (2009) Dynamic out-of-plane profilometry for nano-scale full-field characterization of MEMS using stroboscopic interferometry with novel signal deconvolution algorithm. Opt Laser Eng 47:237–251.  https://doi.org/10.1016/j.optlaseng.2008.05.016CrossRefGoogle Scholar
  20. Creath K (1997) Sampling requirements for white light interferometry. Fringe’97 proceedings of the 3rd international workshop on automatic processing of fringe patterns, pp 52–59Google Scholar
  21. Davidson M, Kaufman K, Mazor I, Cohen F (1987) An application of interference microscopy to integrated circuit inspection and metrology. Proc SPIE 0775.  https://doi.org/10.1117/12.940433
  22. Debnath SK, Kothiyal MP (2005) Optical profiler based on spectrally resolved white light interferometry. Opt Eng 44:013606.  https://doi.org/10.1117/1.1828468CrossRefGoogle Scholar
  23. Debnath SK, Kothiyal MP, Schmit J, Hariharan P (2006a) Spectrally resolved white-light phase-shifting interference microscopy for thickness-profile measurements of transparent thin film layers on patterned substrates. Opt Express 14:4662–4667.  https://doi.org/10.1364/OE.14.004662CrossRefGoogle Scholar
  24. Debnath SK, Kothiyal MP, Schmit J, Hariharan P (2006b) Spectrally resolved phase-shifting interferometry of transparent thin films: sensitivity of thickness measurements. Appl Opt 45:8636–8640.  https://doi.org/10.1364/AO.45.008636CrossRefGoogle Scholar
  25. Debnath SK, You J, Kim S-W (2009) Determination of film thickness and surface profile using reflectometry and spectrally resolved phase shifting interferometry. Int J Precis Eng Manuf 10(5–10).  https://doi.org/10.1007/s12541-009-0086-0CrossRefGoogle Scholar
  26. Deck L, de Groot P (1994) High-speed noncontact profiler based on scanning white-light interferometry. Appl Opt 33:7334–7338.  https://doi.org/10.1364/AO.33.007334CrossRefGoogle Scholar
  27. Dong JLR (2012) Sensitivity analysis of thin-film thickness measurement by vertical scanning white-light interferometry. Appl Opt 51:5668–5675.  https://doi.org/10.1364/AO.51.005668CrossRefGoogle Scholar
  28. Farr K, George N (1992) Beamsplitter cube for white light interferometry. Opt Eng 31:2191–2196.  https://doi.org/10.1117/12.59886CrossRefGoogle Scholar
  29. Fay MF, Dresel T (2017) Applications of model-based transparent surface films analysis using coherence-scanning interferometry. Opt Eng 56:111709.  https://doi.org/10.1117/12.2238997CrossRefGoogle Scholar
  30. Flournoy PA, McClure RW, Wyntjes G (1972) White-light interferometric thickness gauge. Appl Opt 11:1907–1915.  https://doi.org/10.1364/AO.11.001907CrossRefGoogle Scholar
  31. Gao F, Coupland JM, Petzing J (2006) V-groove measurements using white light interferometry. Photon06, ManchesterGoogle Scholar
  32. Gao F, Leach RK, Petzing J, Coupland J (2008) Surface measurement errors using commercial scanning white light interferometers. Meas Sci Technol 19:015303.  https://doi.org/10.1088/0957-0233/19/1/015303CrossRefGoogle Scholar
  33. Giraldez MJ, García-Resúa C, Lira M, Real Oliveira ME, Yebra-Pimentel E (2010) White light interferometry to characterize the hydrogel contact lens surface. Ophtalmic Physiol Opt 30:289–297.  https://doi.org/10.1111/j.1475-1313.201000712xCrossRefGoogle Scholar
  34. Gokhler M, Rosen J (2005a) General configuration for using the longitudinal spatial coherence effect. Opt Commun 252:22–28.  https://doi.org/10.1016/j.optcom.2005.04.007CrossRefGoogle Scholar
  35. Gokhler M, Rosen J (2005b) Synthesis of a multiple-peak spatial degree of coherence for imaging through absorbing media. Appl Opt 44:2921–2927.  https://doi.org/10.1364/AO.44.002921CrossRefGoogle Scholar
  36. Gomez C, Su R, Thompson A, DiSciacca J, Lawes S, Leach RK (2017) Optimization of surface measurement for metal additive manufacturing using coherence scanning interferometry. Opt Eng 56:111714.  https://doi.org/10.1117/1.OE.56.11.111714CrossRefGoogle Scholar
  37. de Groot P, Deck L (1993) Three-dimensional imaging by sub-Nyquist sampling of white-light interferograms. Opt Lett 18:1462–1464.  https://doi.org/10.1364/OL.18.001462CrossRefGoogle Scholar
  38. de Groot P, Deck L (1995) Surface profiling by analysis of white-light Interferograms in the spatial frequency domain. J Mod Opt 42:389–401.  https://doi.org/10.1080/09500349514550341CrossRefGoogle Scholar
  39. de Groot P, de Lega XC, Kramer J, Turzhitsky M (2002) Determination of fringe order in white-light interference microscopy. Appl Opt 41:4571–4578.  https://doi.org/10.1364/AO.41.004571CrossRefGoogle Scholar
  40. de Groot P, de Lega XC (2003) Valve cone measurement using white light interference microscopy in a spherical measurement geometry. Opt Eng 42:1232–1237.  https://doi.org/10.1117/1.1565350CrossRefGoogle Scholar
  41. de Groot P, de Lega XC (2004) Signal modeling for low-coherence height-scanning interference microscopy. Appl Opt 43:4821–4830.  https://doi.org/10.1364/AO.43.004821CrossRefGoogle Scholar
  42. de Groot P (2005) Generating fringe-free images from phase-shifted interferometry data. Appl Opt 44:7062–7069.  https://doi.org/10.1364/AO.44.007062CrossRefGoogle Scholar
  43. de Groot P (2006) Stroboscopic white-light interference microscopy. Appl Opt 45:5840–5844.  https://doi.org/10.1364/AO.45.005840CrossRefGoogle Scholar
  44. de Groot P, de Lega XC (2007a) Angle-resolved three-dimensional analysis of surface films by coherence scanning interferometry. Opt Lett 32:1638–1640.  https://doi.org/10.1364/OL.32.001638CrossRefGoogle Scholar
  45. de Groot P, de Lega X (2007b) Triangulation methods and systems for profiling surfaces through a thin film coating. US Patent 7,292,346, 2007. https://patents.google.com/patent/US7292346B2/en. Accessed 19 Jun 2018
  46. de Groot P (2008) Method and system for analyzing low-coherence interferometry signals for information about thin film structures. US Patent 7,321,431. https://patents.google.com/patent/US20060262321. Accessed 12 Jun 2018
  47. de Groot P, de Lega X, Liesener J, Darwin M (2008) Metrology of optically-unresolved features using interferometric surface profiling and RCWA modeling. Opt Express 16:3970–3975.  https://doi.org/10.1364/OE.16.003970CrossRefGoogle Scholar
  48. de Groot P, Biegen J (2015) A new class of wide-field objectives for 3D interference microscopy. Proc SPIE 9525:95250N.  https://doi.org/10.1117/12.2183628CrossRefGoogle Scholar
  49. de Groot P (2015) Interference microscopy for surface structure analysis. In: Yoshizawa T (ed) Handbook of optical metrology principles and applications, second edition. CRC Press, Boca Raton, pp 791–828Google Scholar
  50. de Groot P (2016) The meaning and measure of vertical resolution in surface metrology. 5th international conference on surface metrology, Poznań, Poland, pp 1–4Google Scholar
  51. Guo T, Li F, Chen J, Fu X, Hu X (2016) Multi-wavelength phase-shifting interferometry for micro-structures measurement based on color image processing in white light interference. Opt Lasers Eng 82:41–47.  https://doi.org/10.1016/j.optlaseng.2016.02.003CrossRefGoogle Scholar
  52. Han S, Novak E, Wissinger J, Guenther BW, Browne T, Yanine E, Schurig M, Herron JD, McCloy C, Li X, Krell MB, Harris J (2005) Surface profiler for fixed through-glass measurement. Proc SPIE 5716:189–197.  https://doi.org/10.1117/12.597080CrossRefGoogle Scholar
  53. Hanhijärvi K, Kassamakov I, Heikkinen V, Aaltonen J, Sainiemi L, Grigoras K, Franssila S, Hæggström E (2012) Stroboscopic supercontinuum white-light interferometer for MEMS characterization. Opt Lett 37:1703–1705.  https://doi.org/10.1364/OL.37.001703CrossRefGoogle Scholar
  54. Hanhijärvi K, Kassamakov I, Aaltonen J, Heikkinen V, Sainiemi L, Franssila S, Hæggström E (2013) Through-silicon stroboscopic characterization of an oscillating MEMS thermal actuator using supercontinuum interferometry. IEEE/ASME Trans Mechatron 18:1418–1420.  https://doi.org/10.1109/TMECH.2012.2235080CrossRefGoogle Scholar
  55. Harasaki A, Schmit J, Wyant JC (2000) Improved vertical-scanning interferometry. Appl Opt 39:2107–2115.  https://doi.org/10.1364/AO.39.002107CrossRefGoogle Scholar
  56. Harasaki A, Wyant JC (2000) Fringe modulation skewing effect in white-light vertical scanning interferometry. Appl Opt 39:2101–2106.  https://doi.org/10.1364/AO.39.002101CrossRefGoogle Scholar
  57. Harasaki A, Schmit J, Wyant JC (2001) Offset of coherent envelope position due to phase change on reflection. Appl Opt 40:2102–2106.  https://doi.org/10.1364/AO.40.002102CrossRefGoogle Scholar
  58. Hariharan P, Oreb BF, Eiju T (1987) Digital phase-shifting interferometry: a simple error-compensating phase calculation algorithm. Appl Opt 26:2504–2506.  https://doi.org/10.1364/AO.26.002504CrossRefGoogle Scholar
  59. Hariharan P (1995) Achromatic retarders using quartz and mica. Meas Sci Technol 6:1078–1079.  https://doi.org/10.1088/0957-0233/6/7/036CrossRefGoogle Scholar
  60. Hariharan P (1996) Achromatic phase-shifting for white-light interferometry. Appl Opt 35:6823–6824.  https://doi.org/10.1364/AO.35.006823CrossRefGoogle Scholar
  61. Hariharan P, Roy M (1996) Interferometric surface profiling with white light: effects of surface films. J Mod Opt 43:1797–1800.  https://doi.org/10.1080/09500349608232850CrossRefGoogle Scholar
  62. Haruna M, Ohmi M, Mitsuyama T, Tajiri H, Maruyama H, Hashimoto M (1998) Simultaneous measurement of the phase and group indices and the thickness of transparent plates by low-coherence interferometry. Opt Lett 23:966–968.  https://doi.org/10.1364/OL.23.000966CrossRefGoogle Scholar
  63. Häusler G, Herrmann JM (1993) Physical limits of 3D sensing. Proc SPIE 1822.  https://doi.org/10.1117/12.141937
  64. Häusler G, Neumann J (1993) Coherence radar: an accurate 3D sensor for rough surfaces. Proc SPIE 1822.  https://doi.org/10.1117/12.141943
  65. Häusler G, Lindner MW (1998) “Coherence radar” and “spectral radar”—new tools for dermatological diagnosis. J Biomed Opt 3:21–31.  https://doi.org/10.1117/1.429899CrossRefGoogle Scholar
  66. Heikkinen V, Kassamakov I, Paulin T, Nolvi A, Hæggström E (2013) Stroboscopic scanning white light interferometry at 2.7 MHz with 1.6 μm coherence length using a non-phosphor LED source. Opt Express 21:5247–5254.  https://doi.org/10.1364/OE.21.005247CrossRefGoogle Scholar
  67. Heikkinen V, Kassamakov I, Seppä J, Paulin T, Nolvi A, Lassila A, Hæggström E (2015) Traceable methods for vertical scale characterization of dynamic stroboscopic scanning white-light interferometer measurements. Opt Express 54:10397–10403.  https://doi.org/10.1364/OE.54.010397CrossRefGoogle Scholar
  68. Helen SS, Kothiyal MP, Sirohi RS (2001) Analysis of spectrally resolved white light Interferograms: use of a phase shifting technique. Opt Eng 40:1329–1336.  https://doi.org/10.1117/1.1383997CrossRefGoogle Scholar
  69. Hirabayashi A, Ogawa H, Kitagawa K (2002) Fast surface profiler by white-light interferometry by use of a new algorithm based on sampling theory. Appl Opt 41:4876–4883.  https://doi.org/10.1364/AO.41.004876CrossRefGoogle Scholar
  70. Hlubina P, Luňáček J, Ciprian D, Chlebus R (2008) Dispersion error of a beam splitter cube in white-light spectral interferometry. Opto-Electron Rev 16:439–443.  https://doi.org/10.2478/s11772-008-0040-1CrossRefGoogle Scholar
  71. Hu X, Deng S, Wang W, Hu X (2009) Long-working-distance Linnik microscopic interferometry for measuring the surface profile of microstructures. J Vac Sci Technol B 27:1403.  https://doi.org/10.1116/1.3046154CrossRefGoogle Scholar
  72. Ikonen E, Riski K (1993) Gauge block interferometer based on one stabilised laser and a whitelight source. Metrologia 30:95–104.  https://doi.org/10.1088/0026-1394/30/2/006CrossRefGoogle Scholar
  73. ISO – International Organization for Standarization (2010) ISO/CD TS 16610-31:2010, geometrical product specifications (GPS) – filtration – part 31: robust profile filters: Gaussian regression filters. https://www.iso.org/standard/42972.html. Accessed 18 Jun 2018
  74. ISO – International Organization for Standarization (2012) ISO/DIS 25178–2:2012 geometrical product specification (GPS) – surface texture: areal – part 2 terms. Definitions and surface texture parameters. https://www.iso.org/standard/42785.html. Accessed 18 Jun 2018
  75. Kang M-G, Lee S-Y, Kim S-W (1999) Self-compensation of PZT errors in white light scanning interferometry. J Opt Soc Korea 3:35–40CrossRefGoogle Scholar
  76. Kassamakov I (2008) Stroboscopic white light interferometry for dynamic characterization of capacitive pressure sensors. J Acoust Soc Am 123:3286.  https://doi.org/10.1121/1.2933663CrossRefGoogle Scholar
  77. Kim S, Kim G (1999) Thickness-profile measurement of transparent thin-film layers by white-light scanning interferometry. Appl Opt 38:5968–5973.  https://doi.org/10.1364/AO.38.005968CrossRefGoogle Scholar
  78. Kim J, Kim K, Pahk HJ (2017) Thickness measurement of a transparent thin film using phase change in white-light phase-shift interferometry. Curr Opt Photon 1:505–513Google Scholar
  79. Kimborough B, Millerd J, Wyant J, Hayes J (2006) Low coherence vibration insensitive Fizeau interferometer. Proc SPIE 6292:62920F.  https://doi.org/10.1117/12.682956CrossRefGoogle Scholar
  80. Kino GS, Chim SSC (1990) Mirau correlation microscope. Appl Opt 29:3775–3783.  https://doi.org/10.1364/AO.29.003775CrossRefGoogle Scholar
  81. Kitagawa K (2014) Surface and thickness profile measurement of a transparent film by three-wavelength vertical scanning interferometry. Opt Lett 39:4172–4175.  https://doi.org/10.1364/OL.39.004172CrossRefGoogle Scholar
  82. Koch A, Ulrich R (1990) Fiber-optic displacement sensor with 0.02 μm resolution by white-light interferometry. Sens. Actuators A Phys 201–207(1990):25.  https://doi.org/10.1016/0924-4247(90)87032-ECrossRefGoogle Scholar
  83. Koudelka PD, Burge JH (2004) Fabrication of cube beamsplitter for white light interferometry. Proc SPIE 5252:17–25.  https://doi.org/10.1117/12.513440CrossRefGoogle Scholar
  84. Kujawińska M, Józwik M, Styk A, Zeitner U, Royset A, Beer S, Moosburger R, Gorecki C, Gastinger K (2010) Design, technology and signal processing for DOE-based microinterferometer array applied in new generation M(O)EMS test equipment. Proc SPIE 7791:779103–779101.  https://doi.org/10.1117/12.862170CrossRefGoogle Scholar
  85. Küchel MF (2004) Zygo’s new method to reduce intrinsic noise in interferometers. https://www.zygo.com/library/papers/optatec2004.pdf. Accessed 13 Jun 2018
  86. Larkin KG (1996a) Efficient nonlinear algorithm for envelope detection in white light interferometry. JOSA 13:832–843.  https://doi.org/10.1364/JOSAA.13.000832CrossRefGoogle Scholar
  87. Larkin KG (1996b) Efficient demodulator for bandpass sampled AM signals. Electron Lett 32:101–102.  https://doi.org/10.1049/el:19960081CrossRefGoogle Scholar
  88. Lee BS, Strand TC (1990) Profilometry with a coherence scanning microscope. Appl Opt 29:3784–3788.  https://doi.org/10.1364/AO.29.003784CrossRefGoogle Scholar
  89. de Lega XC, de Groot P (2008a) Characterization of materials and film stacks for accurate surface topography measurement using a white-light optical profiler. Proc SPIE 6995:69950P.  https://doi.org/10.1117/12.782836CrossRefGoogle Scholar
  90. de Lega XC, de Groot P (2008b) Transparent film profiling and analysis by interference microscopy. Proc SPIE 7064:70640I.  https://doi.org/10.1117/12.794936CrossRefGoogle Scholar
  91. Lehmann P (2003) Optical versus tactile geometry measurement – alternatives or counterparts. Proc SPIE 5144:183–196.  https://doi.org/10.1117/12.508360CrossRefGoogle Scholar
  92. Li Y, Kästner M, Reithmeier E (2017) Vibration-insensitive low coherence interferometer (LCI) for the measurement of technical surfaces. Measurement 104:36–42.  https://doi.org/10.1016/j.optlaseng.2016.02.003CrossRefGoogle Scholar
  93. Lindner MW (2002) White-light interferometry via an endoscope. Proc SPIE 4777.  https://doi.org/10.1117/12.472208
  94. Lindner M, Thominet V (2005) Optical measuring device. US Patent US 6970253 2005. https://patents.google.com/patent/US6970253. Accessed 20 Jun 2018
  95. Linnik VP (1933) Ein apparat fur mikroskopisch-interferometrische untersuchung reflektierender objekte (mikrointerferometer). Akademiya Nauk SSSR Doklady 21:18–23Google Scholar
  96. Liżewski K, Tomczewski S, Kozacki T, Kostencka J (2014) High-precision topography measurement through accurate in-focus plane detection with hybrid digital holographic microscope and white light interferometer module. Appl Opt 53:2446–2454.  https://doi.org/10.1364/AO.53.002446CrossRefGoogle Scholar
  97. Lyakin DV, Ryabukho VP (2013) Longitudinal correlation properties of an optical field with broad angular and frequency spectra and their manifestation in interference microscopy. Quantum Electron 43:949.  https://doi.org/10.1070/QE2013v043n10ABEH015187CrossRefGoogle Scholar
  98. Lyulko OV, Randers-Pehrson G, Brenner DJ (2013) Simultaneous immersion Mirau interferometry. Rev Sci Instrum 84:053701.  https://doi.org/10.1063/1.4803181CrossRefGoogle Scholar
  99. Ma S, Quan C, Zhu R, Tay CJ, Chen L (2011) Surface profile measurement in white-light scanning interferometry using a three-chip color CCD. Appl Opt 50:2246–2254.  https://doi.org/10.1364/AO.50.002246CrossRefGoogle Scholar
  100. Machleidt T, Kollhoff D, Dathe O, Kapusi O, Nestler R, Franke K-H (2012) Application of color cameras for 3D surface measurements with white light interferometers. 14th SpectroNet collaboration forum AM in JenaGoogle Scholar
  101. Malacara D (2007) Optical shop testing, 3rd edn. Wiley, HobokenCrossRefGoogle Scholar
  102. Mansfield D (2006) The distorted helix: thin film extraction from scanning white light interferometry. Proc SPIE 6186:61860O.  https://doi.org/10.1117/12.664036CrossRefGoogle Scholar
  103. Mandel L, Wolf E (1995) Optical coherence and quantum optics, 1st edn. Cambridge University Press, CambridgeCrossRefGoogle Scholar
  104. Mirau AH (1949) Interferometer. US Patent 2,612,074. https://patents.google.com/patent/US2612074. Accessed 12 Jun 2018
  105. Mun JI, Jo T, Kim T, Pahk HJ (2015) Residual vibration reduction of white-light scanning interferometry by input shaping. Opt Express 23:464–470.  https://doi.org/10.1364/OE.23.000464CrossRefGoogle Scholar
  106. Muralikrishnan B, Raja J (2009) Computational surface and roundness metrology. Springer-Verlag, LondonGoogle Scholar
  107. Niehues J, Lehmann P, Xie W (2012) Low coherent Linnik interferometer optimized for use in nano-measuring machines. Meas Sci Technol 23:125002.  https://doi.org/10.1088/0957-0233/23/12/125002CrossRefGoogle Scholar
  108. Novotny S, Durairaj V, Shavrin I, Lipiäinen L, Kokkonen K, Kaivola M, Ludvigsen H (2014) Picosecond supercontinuum light source for stroboscopic white-light interferometry with freely adjustable pulse repetition rate. Opt Express 22:13625–13633.  https://doi.org/10.1364/OE.22.013625CrossRefGoogle Scholar
  109. Olszak A, Schmit J (2003) High-stability white-light interferometry with reference signal for real-time correction of scanning errors. Opt Eng 42:54–59.  https://doi.org/10.1117/1.1523942CrossRefGoogle Scholar
  110. Palmer JM (1993) Getting intense about intensity. Metrologia 30:371–372.  https://doi.org/10.1088/0026-1394/30/4/030CrossRefGoogle Scholar
  111. Park M-C, Kim S-W (2001) Compensation of phase change on reflection in white-light interferometry for step height measurement. Opt Lett 26:420–422.  https://doi.org/10.1364/OL.26.000420CrossRefGoogle Scholar
  112. Pavliček P, Soubusta J (2003) Theoretical measurement uncertainty of white-light interferometry on rough surfaces. Appl Opt 42:1809–1813.  https://doi.org/10.1364/AO.42.001809CrossRefGoogle Scholar
  113. Pavliček P, Soubusta J (2004) Measurement of the influence of dispersion on white-light interferometry. Appl Opt 43:766–770.  https://doi.org/10.1364/AO.43.000766CrossRefGoogle Scholar
  114. Pavliček P, Halouzka M, Duan Z, Takeda M (2009) Spatial coherence profilometry on tilted surfaces. Appl Opt 48:H40–H47.  https://doi.org/10.1364/AO.48.000H40CrossRefGoogle Scholar
  115. Petitgrand S, Yahiaoui R, Danaie K, Bosseboeuf A, Gilles J (2001) 3D measurement of micromechanical devices vibration mode shapes with a stroboscopic interferometric microscope. Opt Laser Eng 36:77–101.  https://doi.org/10.1016/S0143-8166(01)00040-9CrossRefGoogle Scholar
  116. Pfärtner A, Schwider J (2001) Dispersion error in white-light Linnik interferometers and its applications for evaluation procedures. Appl Opt 40(34):6223–6228.  https://doi.org/10.1364/AO.40.006223CrossRefGoogle Scholar
  117. Pförtner A, Schwider J (2003) Red-green-blue interferometer for the metrology of discontinuous structures. Appl Opt 42:667–673.  https://doi.org/10.1364/AO.42.000667CrossRefGoogle Scholar
  118. Rao Y-J, Jackson DA (1996) Recent progress in fibre optic low-coherence interferometry. Meas Sci Technol 7:981–999.  https://doi.org/10.1088/0957-0233/7/7/001CrossRefGoogle Scholar
  119. Recknagel R, Notni G (1998) Analysis of white light interferograms using wavelet methods. Opt Commun 148:122–128.  https://doi.org/10.1016/S0030-4018(97)00644-5CrossRefGoogle Scholar
  120. Reolon D, Jacquot M, Verrier I, Brun G, Veillas C (2006) Broadband supercontinuum interferometer for high-resolution profilometry. Opt Express 14:128–137.  https://doi.org/10.1364/OPEX.14.000128CrossRefGoogle Scholar
  121. Rhee H-G, Lee Y-W, Vorburger TV, Reneger TB (2006) Surface topography measurement and analysis for bullet and casing signature identification. Korean J Opt Photon 17:47–53.  https://doi.org/10.3807/KJOP.2006.17.1.047CrossRefGoogle Scholar
  122. Rosen J, Takeda M (2000) Longitudinal spatial coherence applied for surface profilometry. Appl Opt 39:4107–4111.  https://doi.org/10.1364/AO.39.004107CrossRefGoogle Scholar
  123. Roy M, Cooper I, Moore P, Sheppard CJR, Hariharan P (2005) White-light interference microscopy: effects of multiple reflections within a surface film. Opt Express 13:164–170.  https://doi.org/10.1364/OPEX.13.000164CrossRefGoogle Scholar
  124. Ryabukho V, Lyakin D, Lobachev M (2004) Influence of longitudinal spatial coherence on the signal of a scanning interferometer. Opt Lett 29:667–669.  https://doi.org/10.1364/OL.29.000667CrossRefGoogle Scholar
  125. Safrani A, Abdulhalim I (2011) Spatial coherence effect on layer thickness determination in narrowband full-field optical coherence tomography. Appl Opt 50:3021–3027.  https://doi.org/10.1364/AO.50.003021CrossRefGoogle Scholar
  126. Safrani A, Abdulhalim I (2012) Ultrahigh-resolution full-field optical coherence tomography using spatial coherence gating and quasi-monochromatic illumination. Opt Lett 37:458–460.  https://doi.org/10.1364/OL.37.000458CrossRefGoogle Scholar
  127. Saleh BEA, Teich MC (2007) Fundamentals of photonics, 2nd edn. Wiley, HobokenGoogle Scholar
  128. Salsbury C, Olszak A (2017) Spectrally controlled interferometry. Appl Opt 56:7781–7788.  https://doi.org/10.1364/AO.56.007781CrossRefGoogle Scholar
  129. Sandoz P, Tribillon G, Perrin H (1996) High resolution profilometry by using phase calculation algorithms for spectroscopic analysis of white light Interferograms. J Mod Opt 43:701–708.  https://doi.org/10.1080/09500349608232777CrossRefGoogle Scholar
  130. Sandoz P (1997) Wavelet transform as a processing tool in white-light interferometry. Opt Lett 22:1065–1067.  https://doi.org/10.1364/OL.22.001065CrossRefGoogle Scholar
  131. Schmit J, Olszak A (2002) High-precision shape measurement by white-light interferometry with real-time scanner error correction. Appl Opt 41:5943–5950.  https://doi.org/10.1364/AO.41.005943CrossRefGoogle Scholar
  132. Schmit J (2003) High speed measurements using optical profiler. Proc SPIE 5144:46–56.  https://doi.org/10.1117/12.501035CrossRefGoogle Scholar
  133. Schmit J, Unruh P, Tavrov AV, Kerwien N, Osten W, Tiziani H (2003) Coherence effects in narrow trench measurements using white light interferometry. Frontiers in Optics, OSA Technical Digest, MT41.  https://doi.org/10.1364/FIO.2003.MT41
  134. Schmit J, Hariharan P (2007) Improved polarization Mirau interference microscope. Opt Eng 46:077007.  https://doi.org/10.1117/1.2751166CrossRefGoogle Scholar
  135. Schmit J, Han S, Novak E (2009) Ball bearing measurement with white light interferometry. Proc SPIE 7389:73890P.  https://doi.org/10.1117/12.828113CrossRefGoogle Scholar
  136. Schmit J (2013) White-light interference 3D microscopes. In: Harding K (ed) Handbook of optical dimensional metrology. Taylor & Francis, Boca Raton, pp 395–418CrossRefGoogle Scholar
  137. Schmit J, Novak M, Bui S (2015) 3D interferometric microscope: color visualization of engineered surfaces for industrial applications. Proc SPIE 9576:957607.  https://doi.org/10.1117/12.2190352CrossRefGoogle Scholar
  138. Schmit J (2015) 3D white light interference microscope with specialized illumination for better sample imaging and observation. In: Jabłoński R, Brezina T (eds) Advanced mechatronics solutions. Springer, Cham, pp 553–558Google Scholar
  139. Schreiber H, Bruning JH (2007) Phase shifting interferometry. Ch. In: Malacara D (ed) Optical shop testing., 3rd edn, vol 14. Wiley, Hoboken, pp 547–666CrossRefGoogle Scholar
  140. Schulz LG (1951) The effect of phase changes in white light interferometry. J Opt Soc Am 41:261–264.  https://doi.org/10.1364/JOSA.41.000261CrossRefGoogle Scholar
  141. Schwider J, Burow R, Elssner K-E, Grzanna J, Spolarczyk R, Merkel K (1983) Digital wave-front measuring interferometry: some systematic error sources. Appl Opt 22:3421–3432.  https://doi.org/10.1364/AO.22.003421CrossRefGoogle Scholar
  142. Schwider J, Zhou L (1994) Dispersive interferometric profilometer. Opt Lett 19:995–997.  https://doi.org/10.1364/OL.19.000995CrossRefGoogle Scholar
  143. Shavrin I, Lipiäinen L, Kokkonen K, Novotny S, Kaivola M, Ludvigsen H (2013) Stroboscopic white-light interferometry of vibrating microstructures. Opt Express 21:16901–16907.  https://doi.org/10.1364/OE.21.016901CrossRefGoogle Scholar
  144. Stout KJ (ed) (2000) Development of methods for the characterisation of roughness in three dimension. Penton Press, LondonGoogle Scholar
  145. Styk A, Lambelet P, Royset A, Kujawińska M, Gastinger K (2010) Smart pixel camera based singnal processing in an interferometric test stadion for massive paralel inspection of MEMS and MOEMS. Proc SPIE 7387:73870M-1/10.  https://doi.org/10.1117/12.871522CrossRefGoogle Scholar
  146. Sun C, Yu L, Sun Y, Yu Q (2005) Scanning white-light interferometer for measurement of the thickness of a transparent oil film on water. Appl Opt 44:5202–5205.  https://doi.org/10.1364/AO.44.005202CrossRefGoogle Scholar
  147. Takeda M, Yamamoto H (1994) Fourier-transform speckle Profilometry: three-dimensional shape measurements of diffuse objects with large height steps and/or spatially isolated surfaces. Appl Opt 33:7829–7837.  https://doi.org/10.1364/AO.33.007829CrossRefGoogle Scholar
  148. Tapilouw AM, Chen LC, Jen YJ, Lin ST, Yeh SL (2013) Orthogonal polarization Mirau interferometer using reflective-type waveplate. Opt Lett 38:2502–2504.  https://doi.org/10.1364/OL.38.002502CrossRefGoogle Scholar
  149. Tavrov A, Schmit J, Kerwien N, Osten W, Tiziani H (2005) Diffraction-induced coherence levels. Appl Opt 44:2202–2212.  https://doi.org/10.1364/AO.44.002202CrossRefGoogle Scholar
  150. Tereschenko S, Lehmann P, Zellmer L, Brueckner-Foit A (2016) Passive vibration compensation in scanning white-light interferometry. Appl Opt 55:6172–6182.  https://doi.org/10.1364/AO.55.006172CrossRefGoogle Scholar
  151. Tomczewski S, Pakuła A, Van Erps J, Thienpont H, Sałbut L (2013) Low-coherence interferometry with polynomial interpolation on compute unified device architecture-enabled graphics processing units. Opt Eng 52:094105.  https://doi.org/10.1117/1.OE.52.9.094105CrossRefGoogle Scholar
  152. Upputuri PK, Gong L, Wang H, Pramanik M, Mohan Nandigana K, Kothiyal MP (2014) Measurement of large discontinuities using single white light interferogram. Opt Express 22:27373–27380.  https://doi.org/10.1364/OE.22.027373CrossRefGoogle Scholar
  153. Wan DS (2009) Measurement of thin films using Fourier amplitude. US Patent 7,612,891. https://patents.google.com/patent/US7612891B2/en. Accessed 12 Jun 2018
  154. Wang W, Kozaki H, Rosen J, Takeda M (2002) Synthesis of longitudinal coherence functions by spatial modulation of an extended light source: a new interpretation and experimental verifications. Appl Opt 41:1962–1971.  https://doi.org/10.1364/AO.41.001962CrossRefGoogle Scholar
  155. Wang D, Liang R (2016) Simultaneous polarization Mirau interferometer based on pixelated polarization camera. Opt Lett 41:41–44.  https://doi.org/10.1364/OL.41.000041CrossRefGoogle Scholar
  156. Wiersma JT, Wyant JC (2013) Vibration insensitive extended range interference microscopy. Appl Opt 52:5957–5961.  https://doi.org/10.1364/AO.52.005957CrossRefGoogle Scholar
  157. Wiesner B, Hybl O, Häusler G (2012) Improved white-light interferometry on rough surfaces by statistically independent speckle patterns. Appl Opt 51:751–757.  https://doi.org/10.1364/AO.51.000751CrossRefGoogle Scholar
  158. Wyant JC, Schmit J (1998) Large field of view, high spatial resolution, surface measurements. Int J Mach Tools Manufact 38:691–698CrossRefGoogle Scholar
  159. Xu Z, Shilpiekandula V, Youceftoumi K, Yoon SF (2009) White-light scanning interferometer for absolute nano-scale gap thickness measurement. Opt Express 17:15104–15117.  https://doi.org/10.1364/OE.17.015104CrossRefGoogle Scholar
  160. Yamada R., Itoh M, Tian RL, Tsai M, Yatagai T (1994) Broad-band light-wave correlation topography using wavelet transform. Technical abstract, ICO topical meeting, KyotoGoogle Scholar
  161. Yatagai T (1994) Recent progress in white light interferometry. Proc SPIE 2340:338–345.  https://doi.org/10.1117/12.195930CrossRefGoogle Scholar
  162. Yoshino H, Abbas A, Kaminski PM, Smith R, Walls JM, Mansfield D (2017) Measurement of thin film interfacial surface roughness by coherence scanning interferometry. J Appl Phys 121:105303.  https://doi.org/10.1063/1.4978066CrossRefGoogle Scholar
  163. Zuluaga AF, Richards-Kortum R (1999) Spatially resolved spectral interferometry for determination of subsurface structure. Opt Lett 24:519–521.  https://doi.org/10.1364/OL.24.000519CrossRefGoogle Scholar

Copyright information

© Springer Nature Switzerland AG 2019

Authors and Affiliations

  1. 1.4D TechnologyTucsonUSA
  2. 2.Warsaw University of TechnologyWarsawPoland

Section editors and affiliations

  • Ida Nathan
    • 1
  • Norbert Meyendorf
    • 2
  1. 1.Department of Electrical and Computer EngineeringUniversity of AkronAkronUSA
  2. 2.Center for Nondestructive EvaluationIowa State UniversityAmesUSA

Personalised recommendations