Skip to main content

Sequencing Using Fluorescent-Labeled Nucleotides

  • Protocol
Book cover E. coli Plasmid Vectors

Part of the book series: Methods in Molecular Biology™ ((MIMB,volume 235))

  • 7011 Accesses

Abstract

The most widespread method used for DNA sequencing today is the Sanger dideoxy method that was first described in 1977 (1). This method takes advantage of the requirement for a free 3′ hydroxyl group to form the necessary phosphodiester bridge between two nucleotides during DNA polymerization. In short, DNA sequencing reactions using this method are performed on a DNA template using a specific primer, DNA polymerase, and a mixture of deoxynucleotidetriphosphates (dNTPs) and dideoxynucleotides (ddNTPs) as a substrate. When a dNTP is incorporated into a growing DNA strand, chain elongation proceeds normally. However, when a ddNTP is incorporated by the polymerase, the process of chain elongation is aborted because of the absence of the 3′ hydroxyl group on the nucleotide analog. The resulting DNA polymerization products are of varying lengths depending on when a ddNTP was incorporated into the growing strand. Theoretically, there should be a ddNTP incorporated at least once at each of the base positions for any particular DNA template. This pool of DNA fragments is then separated by size on high-resolution polyacrylamide gels. The resolution of these gels is so high that the difference in size resulting from a single nucleotide can be determined.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

References

  1. Sanger, F., Nicklen, S., and Couldon, A. R. (1977) DNA sequencing with chain-terminating inhibitors. Proc. Nat. Acad. Sci. USA 92, 6339–6343.

    Google Scholar 

  2. Prober, J., Trainor, G., Dam, R., et al. (1987) A system for rapid DNA sequencing with fluorescent chain-terminating dideoxynucleotides. Science 238, 336–341.

    Article  PubMed  CAS  Google Scholar 

  3. Ansorge, W., Sproat, B., Stegemann, J., et al. (1987) Automated DNA sequencing: ultrasensitive detection of fluorescent bands during electrophoresis. Nucleic Acids Res. 15, 4593–4602.

    Article  PubMed  CAS  Google Scholar 

  4. Zagursky, R. and McCormick, R. (1990) DNA sequencing separations in capillary gels on a modified commercial DNA sequencing instrument. BioTechniques 9, 74–79.

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2003 Humana Press Inc.

About this protocol

Cite this protocol

Gillaspy, A.F. (2003). Sequencing Using Fluorescent-Labeled Nucleotides. In: Casali, N., Preston, A. (eds) E. coli Plasmid Vectors. Methods in Molecular Biology™, vol 235. Humana Press. https://doi.org/10.1385/1-59259-409-3:195

Download citation

  • DOI: https://doi.org/10.1385/1-59259-409-3:195

  • Publisher Name: Humana Press

  • Print ISBN: 978-1-58829-151-6

  • Online ISBN: 978-1-59259-409-2

  • eBook Packages: Springer Protocols

Publish with us

Policies and ethics