Abstract
Capillary electrophoresis (CE) has become an alternative to slab-gel electrophoresis for DNA separations due to its many advantages such as speed, increased separation efficiency, requires minute amount of sample, and automation of sample loading (1) Currently, high-throughput DNA sequencing is performed exclusively by slab-gel electrophoresis coupled to fluorescence detection systems. However, slab-gel electrophoresis involves labor-intensive steps such as gel pouring, sample loading, and long electrophoretic run times. These disadvantages reduce the overall throughput efficiency of a slab-gel system making it less than ideal. One of the main goals of the Human Genome and other large scale sequencing projects is to increase the throughput rate with a commensurate reduction in the cost-per-base sequenced. A limitation of CE has been that only one capillary could be run and monitored at a time, so that the total experimental throughput is no better than with slower slab-gel system with multiple lanes. However, the recent introduction of the multiple capillary instruments, such as the ABI Prism 3700 DNA Analyzer (2) and the MegaBACE (3), may have the potential to meet the high throughput demand.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Heller, C. (1997) The separation matrix, in Analysis of Nucleic Acids by Capillary Electrophoresis (Heller, C., ed.), Friedr. Vieweg & Sohn Verlagsgesellschaft, Braunschweig, Germany, pp. 3–23.
ABI Prism 3700 DNA Analyzer. (1998) User’s Reference Manual. Applied Biosystems Division-Perkin Elmer, Foster City, CA.
MegaBACE. (1998) Instrument User’s Guide. Molecular Dynamics-Amersham Pharmacia Biotech, Sunnyvale, CA.
Hjerten, S. (1985) High-performance electrophoresis: elimination of electroendosmosis and solute adsorption. J. Chromatogr. A. 347, 191–198.
Salomon, K., Burgi, D. S., and Helmer, J. C. (1991) Evaluation of fundamental properties of a silica capillary used for capillary electrophoresis. J. Chromatogr. A. 559, 69–80.
Chiari, M. and Gelain, A. (1997) Developments in capillary coating and DNA separation matrices, in Analysis of Nucleic Acids by Capillary Electrophoresis (Heller, C., ed.), Friedr. Vieweg & Sohn Verlagsgesellschaft, Braunschweig, Germany, pp. 135–173.
Fung, E. N. and Yeung, E. S. (1995) High-speed DNA sequencing by using mixed poly(ethylene oxide) solutions in uncoated capillary columns. Anal. Chem. 67, 1913–1919.
Wehr, T. (1993) Recent advances in capillary electrophoresis columns. LC-GC 11, 14–20.
Madabhushi, R. S. (1998) Separation of 4-color DNA sequencing extension products in non-covalently coated capillaries using low viscosity polymer solutions. Electrophoresis 19, 224–230.
Cobb, K. A., Dolnik, V., and Novotny, M. (1990) Electrophoretic separation of proteins in capillaries with hydrolytically stable surface structure. Anal. Chem. 62, 2478–2483.
Dolnik, V., Xu, D., Yadav, A., Bashkin, J., Marsh, M., Tu, O., Mansfield, E., Vainer, M., Madabhushi, R., Barker, D., and Harris, D. (1998) Wall coating for DNA sequencing and fragment analysis by capillary electrophoresis. J. Microcolumn Seps. 10, 175–184.
Dolnik, V., Chiari, M., Xu, D., Dell’Orto, N., Melis, A., and Harris, D. (1998) A stable wall coating for DNA sequencing by capillary electrophoresis. International Symposium on High Performance Capillary Electrophoresis, February 1-5, Orlando, FL.
Menchen, S., Johnson, B., Winnik, M. A., and Xu, B. (1996) Flowable networks as DNA sequencing media in capillary columns. Electrophoresis 17, 1451–1459.
Carrilho, E., Ruiz-Martinez, M. C., Berka, J., Smirnov, I., Goetzinger, W., Miller, A. W., Brady, D., and Karger, B. L. (1996) Rapid DNA sequencing of more than 1000 bases per run by capillary electrophoresis using replaceable linear polyacrylamide solutions. Anal. Chem. 68, 3305–3313.
Salas-Solano, O., Carrilho, E., Kotler, L., Miller, A. W., Goetzinger, W., Sosic, Z., and Karger, B. L. (1998) Routine DNA sequencing of 1000 bases in less than one hour by capillary electrophoresis with replaceable linear polyacrylamide solutions. Anal. Chem. 70, 3996–4003.
Cifuentes, A., Diez-Masa, J. C., Fritz, J., Anselmetti, D., Bruno, A. E. (1998) Polyacrylamide-coated capillaries probed by atomic force microscopy: Correlation between surface topography and electrophoretic performance. Anal. Chem. 70, 3458–3462.
Madabhushi, R. S., Menchen, S. M., Efcavitch, J. W., and Grossman, P. D. (1996) Polymers for separation of biomolecules by capillary electrophoresis. US Patent Number 5,567,292.
Kim, Y. and Yeung, E. S. (2001) Capillary electrophoresis of DNA fragments using poly(ethylene oxide) as a sieving material, in Capillary Electrophoresis of Nucleic Acids, Vol. 1 (Mitchelson, K. R. and Cheng, J., eds.), Humana Press, Totowa, NJ, pp. 215–223.
Gao, Q.-F. and Yeung, E. S. (1998) A matrix for DNA separation: Genotyping and sequencing using poly(vinylpyrrolidone) solution in uncoated capillaries. Anal. Chem. 70, 1382–1388.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2001 Humana Press Inc.
About this protocol
Cite this protocol
Madabhushi, R. (2001). DNA Sequencing in Noncovalently Coated Capillaries Using Low Viscosity Polymer Solutions. In: Mitchelson, K.R., Cheng, J. (eds) Capillary Electrophoresis of Nucleic Acids. Methods in Molecular Biology™, vol 163. Humana Press. https://doi.org/10.1385/1-59259-116-7:309
Download citation
DOI: https://doi.org/10.1385/1-59259-116-7:309
Publisher Name: Humana Press
Print ISBN: 978-0-89603-765-6
Online ISBN: 978-1-59259-116-9
eBook Packages: Springer Protocols