Energy Dispersive X-Ray Microanalysis

  • Don A. Samuelson
Part of the Methods in Molecular Biology™ book series (MIMB, volume 108)

Abstract

In the past, the principal techniques of choice for analyzing tissue for various inorganic atomic species have been colometric and via atomic absorption spectrophotometry (1). Although both methods can be accurate and precise when performed in the same laboratory, there are disadvantages, which include interlaboratory variability in results owing to sample preparation and instrumentation, and the need for relatively large amounts of tissue to be analyzed. As a result, one is unaware of exactly what structure or cell type in the sample is the source of ions. An alternative technique is the use of energy dispersive X-ray microanalysis (EDX), which allows multi-element analysis at the subcellular level.

Keywords

Formalin HPLC Arsenic Epoxy Propane 

References

  1. 1.
    Potts, A M. and Au, P C (1976) The affinity of melanin for inorganic ions Exp. Eye Res 22, 487–491PubMedCrossRefGoogle Scholar
  2. 2.
    Russ, J. C (1973) Microanalysis of thin sections in the TEM and STEM using energy-dispersive X-ray analysis, in Electron Microscopy and Cytochemistry Wisse, E. Daemes, W T., Molenaar, I., and van Duijn, P. eds, North-Holland Publishing Co, Amsterdam, pp. 223–228Google Scholar
  3. 3.
    Chandler, J. A. (1973) The use of wavelength dispersive X-ray microanalysis in cytochemistry, in Electron Microscopy and Cytochemistry (Wisse, E, Daemes, W T., Molenaar, I., and van Duijn, P., eds.), North-Holland Publishing Co, Amsterdam, pp 203–222Google Scholar
  4. 4.
    Gilkey, J C. and Staehelin, L. A. (1986) Advances in ultrarapid freezing for the preservation of cellular ultrastructure. J Elec Microsc. Tech 3, 177–210.CrossRefGoogle Scholar
  5. 5.
    Hutchinson, T. E. (1977) Energy dispersive X-ray microanalysis, in Analytical and Quantitative Methods in Microscopy (Meek, G A and Elder, H Y., eds.), Cambridge University Press, Cambridge, UK, pp. 213–226.Google Scholar
  6. 6.
    Appleton, T. C (1977) The use of ultrathin frozen sections for X-ray microanalysis of diffusible elements, in Analytical and Quantitative Methods in Microscopy (Meek, G A and Elder, H. Y, eds.), Cambridge University Press, Cambridge, UK, pp. 247–268.Google Scholar
  7. 7.
    Samuelson, D A., Armstrong, D., and Jolly, R. (1990) X-ray microprobe analysis of the retina and RPE in sheep with ovine ceroid-lipofuscinosis Neurobiol. Aging 11, 663–667.Google Scholar
  8. 8.
    Hyatt, M A. (1970) Principles and Techniques of Electron Microscopy, (vol. I), Biological Applications. Van Nostran Reinhold Co., NY, pp. 13–104.Google Scholar
  9. 9.
    Samuelson, D A, Smith, P., Ulshafer, R. L., Hendricks, D. G., Whitley, R D., Hendricks, H., and Leone, N. C. (1993) X-ray microanalysis of ocular melanin in pigs maintained on normal and low zinc diets. Exp. Eye Res. 56, 63–70.PubMedCrossRefGoogle Scholar
  10. 10.
    Dykstra, M. J. (1992) Biological Electron Microscopy. Plenum Press, NY.Google Scholar
  11. 11.
    Flegler, S. L, Heckman, Jr., J. W., and Klomparens K. L. (1993) Scanning and Transmission Electron Microscopy: An Introduction W H. Freeman and Co., NYGoogle Scholar
  12. 12.
    Samuelson, D A., Smith, P. J, Lewis, P, Chisholm, M and Orr, E. (1995) The effects of varying Zn nutrition, light damage and aging on cationic binding in RPE melanin. Invest Ophthalmol Vis. Sci. 36(Suppl.), 5769Google Scholar
  13. 13.
    Samuelson, D A, Konkal, S, Lewis, P, and Chisholm, M (1996) Changes of metal binding in human RPE melanin and hpofuscin with aging and drusen. Invest Ophthalmol. Vis. Sci. 37(Suppl.), 535Google Scholar

Copyright information

© Humana Press Inc., Totowa, NJ 1998

Authors and Affiliations

  • Don A. Samuelson
    • 1
  1. 1.Graduate Studies and Research, Department of Small Animal Clinical Sciences, College of Veterinary MedicineUniversity of FloridaGainesville

Personalised recommendations