Skip to main content

Optimized Conditions for a Quantitative SELDI TOF MS Protein Assay

  • Protocol
  • First Online:
SELDI-TOF Mass Spectrometry

Part of the book series: Methods in Molecular Biology ((MIMB,volume 818))

Abstract

The development of peptide/protein analyte assays for the purpose of diagnostic tests is driven by multiple factors, including sample availability, required throughput, and quantitative reproducibility. Laser Desorption/ionization mass spectrometry methods (LDI-MS) are particularly well suited for both peptide and protein characterization, and combining chromatographic surfaces directly onto the MS probe in the form of surface enhanced laser desorption/ionization (SELDI)-biochips has improved the reproducibility of analyte detection and provided effective relative quantitation. Here, we provide methods for developing reproducible SELDI-based assays by providing a complex artificial protein matrix background within the sample to be analyzed that allows for a common and reproducible ionization background as well as internal normalization standards. Using this approach, quantitative assays can be developed with CVs typically less than 10% across assays and days. Although the method has been extensively and successfully implemented in association with a protein matrix from E. coli, any other source for the complex protein matrix can be considered as long as it adheres to a set of conditions including the following: (1) the protein matrix must not provide interferences with the analyte to be detected, (2) the protein matrix must be sufficiently complex such that a majority of ion current generated from the desorption of the sample comes from the complex protein matrix, and (3) specific and well-resolved protein matrix peaks must be present within the mass range of the analyte of interest for appropriate normalization.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Protocol
USD 49.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 139.00
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Dhawan, S. (2006) Signal amplification systems in immunoassays: implications for clinical diagnostics. Expert Review of Molecular Diagnostics, 6:749–760.

    Article  PubMed  CAS  Google Scholar 

  2. Wudy, S.A. and Hartmann, M.F. (2004) Gas chromatography-mass spectrometry profiling of steroids in times of molecular biology. Hormone and Metabolic Research, 36:415–22.

    Article  PubMed  CAS  Google Scholar 

  3. Ma, S., Chowdhury, S.K. and Alton, K.B. (2006) Application of mass spectrometry for metabolite identification. Current Drug Metabolism, 7:503–23.

    Article  PubMed  CAS  Google Scholar 

  4. Carpenter, KH and Wiley, V. (2002) Application of tandem mass spectrometry to biochemical genetics and newborn screening. Clinical Chimica Acta, 322:1–10.

    Article  CAS  Google Scholar 

  5. Weinberger, S.R.,. Lomas, L.O. Fung, E.T. and Enderwick, C. (2007) Surface Enhanced Laser Desorption/Ionization Protein Biochip Technology for Proteomics Research and Assay Development. In: Spectral Techniques in Proteomics (ed D. Sem). Taylor & Francis Group, LLC. 101–132.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Lee Lomas .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2012 Springer Science+Business Media, LLC

About this protocol

Cite this protocol

Lomas, L., Clarke, C.H., Thulasiraman, V., Fung, E. (2012). Optimized Conditions for a Quantitative SELDI TOF MS Protein Assay. In: Clarke, C., McCarthy, D. (eds) SELDI-TOF Mass Spectrometry. Methods in Molecular Biology, vol 818. Springer, New York, NY. https://doi.org/10.1007/978-1-61779-418-6_1

Download citation

  • DOI: https://doi.org/10.1007/978-1-61779-418-6_1

  • Published:

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-1-61779-417-9

  • Online ISBN: 978-1-61779-418-6

  • eBook Packages: Springer Protocols

Publish with us

Policies and ethics