Skip to main content

Sample Preparation for Transmission Electron Microscopy

  • Protocol
  • First Online:
Biobanking

Part of the book series: Methods in Molecular Biology ((MIMB,volume 1897))

Abstract

Transmission electron microscopy (TEM) is an ideal device to study the internal structure of cells and different types of biological materials, but adverse conditions inside electron microscopes such as damage induced by electron bombardment and vacuum evaporation of structural water necessitates complex preparation methods to survive this environment. In order to introduce the sample into the evacuated microscope column, it should be stabilized and altered to small enough (about 3 mm in diameter) and thin enough parts to permit the transmission of electrons. Depending on applications different thicknesses are required; for example, in biological research studies usually 300–500 nm thickness is indicated. To stabilize the specimen and preserve the sample structures, different preparation methods are used involving different steps based on the type of study and the specimen, although the ultimate goal of all these preparation technics is to maintain the native structure of the sample. In this chapter, we try to explain the series of steps that involve in preparation. Virtually every step can affect the quality of sample, and therefore it is important to execute each step in detail.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Protocol
USD 49.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 149.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 199.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Difference between TEM and SEM (2012) http://www.differencebetween.net/science/difference-between-tem-and-sem/. Accessed Nov 18, 2015

  2. An introduction to electron microscopy (2010) http://www.nanolab.ucla.edu/pdf/Introduction_to_EM_booklet_July_10.pdf. Accessed Nov 19, 2015

  3. Cowley JM (1988) Reflection electron microscopy: surface and interface characterization by electron optical methods, NATO ASI book series, vol 16. SpringerLink, pp 127–158

    Google Scholar 

  4. Types of Electron Microscope. Sciencelearn Hub. http://sciencelearn.org.nz/Contexts/Exploring-with-Microscopes/Looking-Closer/Types-of-electron-microscope. Accessed Nov 17, 2015

  5. Valentin P, Choi C (2010) “Preparing new cases/specimen collection for processing.” UCLA Department of Pathology and Laboratory Medicine

    Google Scholar 

  6. Valentin P, Choi C (2014) “Primary TEM fixative.” UCLA Department of Pathology and Laboratory Medicine

    Google Scholar 

  7. Valentin P, Choi C (2014) “Phosphate Buffer.” UCLA Department of Pathology and Laboratory Medicine

    Google Scholar 

  8. Valentin P, Choi C (2014) “Phosphate Buffered Osmium Tetroxide Fixatives (Post Fixation).” UCLA Department of Pathology and Laboratory Medicine

    Google Scholar 

  9. Valentin P, Choi C (2006) “Preparing Embedding Media (Eponate 12 Resin).” UCLA Department of Pathology and Laboratory Medicine

    Google Scholar 

  10. Valentin P, Choi C (2014) “Routine Tissue Processing for Electron Microscopy.” UCLA Department of Pathology and Laboratory Medicine

    Google Scholar 

  11. Specimen preparation protocol for transmission (2010) Fred Hutchinson Cancer Research Center. http://sharedresources.fredhutch.org/sites/default/files/EMProceduresManual.pdf. Accessed Dec 14, 2015

  12. Böttcher B (2012) Transmission electron microscopy: preparation of specimens. In: eLS. John Wiley & Sons, Chichester. https://doi.org/10.1002/9780470015902.a0002998.pub2

    Chapter  Google Scholar 

  13. “Transmission electron microscopy.” http://www.slideshare.net/JessaArio/transmission-electron-microscopy-14047650. Accessed 14 Dec 2015

  14. Kanno H, Speedy RJ, Angell CA (1975) Supercooling of water to −92°C under pressure. Science 189(4206):880–881. https://doi.org/10.1126/science.189.4206.880

    Article  CAS  PubMed  Google Scholar 

  15. Winey M, Meehl JB, O’Toole ET, Giddings TH (2014) Conventional transmission electron microscopy. Mol Biol Cell 25(3):319–323. https://doi.org/10.1091/mbc.E12-12-0863

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  16. Standard fixation and embedding protocol for resin section TEM—fixation_standard.pdf. http://web.path.ox.ac.uk/~bioimaging/Documents/fixation_standard.pdf. Accessed Nov 17, 2015

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Negar Khanlou .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Science+Business Media, LLC, part of Springer Nature

About this protocol

Check for updates. Verify currency and authenticity via CrossMark

Cite this protocol

Tizro, P., Choi, C., Khanlou, N. (2019). Sample Preparation for Transmission Electron Microscopy. In: Yong, W. (eds) Biobanking. Methods in Molecular Biology, vol 1897. Humana Press, New York, NY. https://doi.org/10.1007/978-1-4939-8935-5_33

Download citation

  • DOI: https://doi.org/10.1007/978-1-4939-8935-5_33

  • Published:

  • Publisher Name: Humana Press, New York, NY

  • Print ISBN: 978-1-4939-8933-1

  • Online ISBN: 978-1-4939-8935-5

  • eBook Packages: Springer Protocols

Publish with us

Policies and ethics