Abstract
Multiplex immunoassays allow for the rapid profiling of biomarker proteins in biological fluids, using less sample and labor than single immunoassays. This chapter details the methods to develop and manufacture multiplex assays for the Luminex® platform. Although assay development is not included here, the same methods can be used to covalently couple antibodies to the Luminex beads and to label antibodies for the screening of sandwich pairs, if needed. The assay optimization, detection of cross-reactivity, and minimizing antibody interactions and matrix interferences will be addressed.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Tighe P, Negm O, Todd I, Fairclough L (2013) Utility, reliability and reproducibility of immunoassay multiplex kits. Methods 61:23–29
Ellington AA, Kullo IJ, Bailey RK, Klee GG (2010) Antibody-based protein multiplex platforms: technical and operational challenges. Clin Chem 56:186–193
Spindel S, Sapsford KE (2014) Evaluation of optical detection platforms for multiplexed detection of proteins and the need for point-of-care biosensors for clinical use sensors. Sensors (Basel) 14:22313–22341
Marquette CA, Corgier BP, Blum LJ (2012) Recent advances in multiplex immunoassays. Bioanalysis 4:927–936
Todd DJ, Knowlton N, Amato M, Frank MB, Schur PH, Izmailova ES et al (2011) Erroneous augmentation of multiplex assay measurements in patients with rheumatoid arthritis due to heterophilic binding by serum rheumatoid factor. Arthritis Rheum 63:894–903
Fraser S, Soderstrom C (2014) Due diligence in the characterization of matrix effects in a total IL-13 Singulex™ method. Bioanalysis 6:1123–1129
Krika LJ (1999) Human anti-animal antibody interferences in immunological assays. Clin Chem 45:942–956
Jani D, Allinson J, Berisha F, Cowan KJ, Devanarayan V, Gleason C et al (2016) Recommendations for use and fit-for-purpose validation of biomarker multiplex ligand binding assays in drug development. AAPS J 18:1–14
Bastarache JA, Koyama Y, Wickersham NE, Ware LB (2014) Validation of a multiplex electrochemiluminescent immunoassay platform in human and mouse samples. J Immunol Methods 408:13–23
Tighe PJ, Ryder RR, Todd I, Fairclough LC (2015) ELISA in the multiplex era: potentials and pitfalls. Proteomics Clin Appl 9:1862–8354
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2017 Springer Science+Business Media LLC
About this protocol
Cite this protocol
Stephen, L. (2017). Multiplex Immunoassay Profiling. In: Guest, P.C. (eds) Multiplex Biomarker Techniques. Methods in Molecular Biology, vol 1546. Humana, New York, NY. https://doi.org/10.1007/978-1-4939-6730-8_13
Download citation
DOI: https://doi.org/10.1007/978-1-4939-6730-8_13
Published:
Publisher Name: Humana, New York, NY
Print ISBN: 978-1-4939-6729-2
Online ISBN: 978-1-4939-6730-8
eBook Packages: Springer Protocols