Opto-Fluidics Based Microscopy and Flow Cytometry on a Cell Phone for Blood Analysis

  • Protocol
  • First Online:

Part of the book series: Methods in Molecular Biology ((MIMB,volume 1256))

Abstract

Blood analysis is one of the most important clinical tests for medical diagnosis. Flow cytometry and optical microscopy are widely used techniques to perform blood analysis and therefore cost-effective translation of these technologies to resource limited settings is critical for various global health as well as telemedicine applications. In this chapter, we review our recent progress on the integration of imaging flow cytometry and fluorescent microscopy on a cell phone using compact, light-weight and cost-effective opto-fluidic attachments integrated onto the camera module of a smartphone. In our cell-phone based opto-fluidic imaging cytometry design, fluorescently labeled cells are delivered into the imaging area using a disposable micro-fluidic chip that is positioned above the existing camera unit of the cell phone. Battery powered light-emitting diodes (LEDs) are butt-coupled to the sides of this micro-fluidic chip without any lenses, which effectively acts as a multimode slab waveguide, where the excitation light is guided to excite the fluorescent targets within the micro-fluidic chip. Since the excitation light propagates perpendicular to the detection path, an inexpensive plastic absorption filter is able to reject most of the scattered light and create a decent dark-field background for fluorescent imaging. With this excitation geometry, the cell-phone camera can record fluorescent movies of the particles/cells as they are flowing through the microchannel. The digital frames of these fluorescent movies are then rapidly processed to quantify the count and the density of the labeled particles/cells within the solution under test. With a similar opto-fluidic design, we have recently demonstrated imaging and automated counting of stationary blood cells (e.g., labeled white blood cells or unlabeled red blood cells) loaded within a disposable cell counting chamber. We tested the performance of this cell-phone based imaging cytometry and blood analysis platform by measuring the density of red and white blood cells as well as hemoglobin concentration in human blood samples, which showed a good match to our measurement results obtained using a commercially available hematology analyzer. Such a cell-phone enabled opto-fluidics microscopy, flow cytometry, and blood analysis platform could be especially useful for various telemedicine applications in remote and resource-limited settings.

This is a preview of subscription content, log in via an institution.

Buying options

Protocol
USD   49.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   99.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   129.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Springer Nature is developing a new tool to find and evaluate Protocols. Learn more

References

  1. Beck N (2009) Diagnostic hematology. Springer, Berlin

    Book  Google Scholar 

  2. Mellors JW, Munoz A, Giorgi JV, Margolick JB, Tassoni CJ (1997) Plasma viral load and CD4+ lymphocytes as prognostic markers of HIV-1 infection. Ann Intern Med 126:946–954

    Article  CAS  Google Scholar 

  3. Wurm EM, Wellenhof RH, Wurm R, Soyer HP (2008) Telemedicine and teledermatology: past, present and future. J Dtsch Dermatol Ges 6:106–112

    Article  Google Scholar 

  4. Pamplona VF, Mohan A, Oliveira MM, Raskar R (2010) NETRA: interactive display for self-evaluation of an eye for visual accommodation and focal range. Proc. of Frontiers in Optics, 2010, Paper FTuB4.

    Google Scholar 

  5. Breslauer DN, Maamari RN, Switz NA, Lam WA, Fletcher DA (2009) Mobile phone based clinical microscopy for global health applications. PLoS One 4:e6320

    Article  Google Scholar 

  6. Tseng T, Mudanyali O, Oztoprak C, Isikman SO, Sencan I, Yaglidere O, Ozcan A (2010) Lensfree microscopy on a cell-phone. Lab Chip 10:1787–1792

    Article  CAS  Google Scholar 

  7. Zhu H, Yaglidere O, Su T, Tseng D, Ozcan A (2010) Cost-effective and compact wide-field fluorescent imaging on a cellphone. Lab Chip 11:315–322

    Article  Google Scholar 

  8. Zhu H, Mavandadi S, Coskun AF, Yaglidere O, Ozcan A (2011) Opto-fluidic fluorescent imaging cytometry on a cellphone. Anal Chem 83:6641–6647

    Article  CAS  Google Scholar 

  9. Smith ZJ, Chu K, Espenson AF, Rahimzadeh M, Gryshuk A, Molinaro M, Dwyre DM, Lane S, Mattews D, Wachsmann-Hogiu S (2011) Cell-phone-based platform for biomedical device development and education applications. PLoS One 6:e17150

    Article  CAS  Google Scholar 

  10. Martinez AW, Philips ST, Carrilho E, Thomas SW, Sindi H, Whitesides GW (2008) Simple telemedicine for developing regions: camera phones and paper-based microfluidic device for real-time, off-site diagnosis. Anal Chem 80:3699–3707

    Article  CAS  Google Scholar 

  11. Zhu H, Sikora U, Ozcan A (2012) Quantum dot enabled detection of Escherichia coli using a cell-phone. Analyst 137:2541–2544

    Article  CAS  Google Scholar 

  12. Mudanyali O, Dimitrov S, Sikora U, Padmanabhan S, Navruz I, Ozcan A (2012) Integrated rapid-diagnostic-test reader platform on a cellphone. Lab Chip 12:2678–2686

    Article  CAS  Google Scholar 

  13. Preechaburana P, Gonzalez MC, Suska A, Flippini D (2012) Surface plasmon resonance chemical sensing on cell phones. Angew Chem Int Ed 12:11585–11588

    Article  Google Scholar 

  14. Coskun A, Wong J, Khodadah D, Nagi R, Tey A, Ozcan A (2012) A personalized food allergen testing platform on a cellphone. Lab Chip 13:636–640

    Article  Google Scholar 

  15. You DJ, Park TS, Yoon J (2013) Cell-phone-based measurement of TSH using Mie scatter optimized lateral flow assays. Biosens Bioelectron 40:180–185

    Article  CAS  Google Scholar 

  16. Navruz I, Coskun AF, Wong J, Mohammad S, Tseng D, Nagi R, Phillips S, Ozcan A (2013) Smart-phone based computational microscopy using multi-frame contact imaging on a fiber-optic array. Lab Chip 13:4015–4023

    Article  CAS  Google Scholar 

  17. Zhu H, Sencan I, Wong J, Dimitrov S, Tseng O, Nagashima K, Ozcan A (2013) Cost-effective and rapid blood analysis on a cell-phone. Lab Chip 13:1282–1288

    Article  CAS  Google Scholar 

  18. Balsam J, Rasooly R, Bruck HA, Rasooly A (2014) Thousand-fold fluorescent signal amplification for mHealth diagnostics. Biosens Bioelectron 51:1–7

    Article  CAS  Google Scholar 

  19. International Telecommunication Union, Market information and statistics (2013). http://www.itu.int/en/ITU-D/Statistics/Documents/facts/ICTFactsFigures2013.pdf

  20. Schmidt O, Bassler M, Kiesel P, Knollenberg C, Johnson N (2007) Fluorescent spectrometer-on-a-fluidic-chip. Lab Chip 7:626–629

    Article  CAS  Google Scholar 

  21. Kiesel P, Beck M, Johnson N (2011) Monitoring CD4 in whole blood with an opto-fluidic detector based on spatially modulated fluorescence emission. Cytometry A 79A:317–324

    Article  Google Scholar 

  22. Suzuki S, Abe K (1985) Topological structural analysis of digital binary image by border following. Vis Graph Image Process 30:32–46

    Article  Google Scholar 

  23. Ozcan A, Demirci U (2008) Ultra wide-field lens-free monitoring of cells on-chip. Lab Chip 8:98–106

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Aydogan Ozcan .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer Science+Business Media New York

About this protocol

Cite this protocol

Zhu, H., Ozcan, A. (2015). Opto-Fluidics Based Microscopy and Flow Cytometry on a Cell Phone for Blood Analysis. In: Rasooly, A., Herold, K. (eds) Mobile Health Technologies. Methods in Molecular Biology, vol 1256. Humana Press, New York, NY. https://doi.org/10.1007/978-1-4939-2172-0_12

Download citation

  • DOI: https://doi.org/10.1007/978-1-4939-2172-0_12

  • Published:

  • Publisher Name: Humana Press, New York, NY

  • Print ISBN: 978-1-4939-2171-3

  • Online ISBN: 978-1-4939-2172-0

  • eBook Packages: Springer Protocols

Publish with us

Policies and ethics