Abstract
Differential mobility spectrometry (DMS) is capable of separating molecules based on their size and shape. When coupled to mass spectrometry (MS), DMS reduces chemical background and enhances signal-to-noise (S/N) ratio. Flow injection analysis (FIA) is a technique used to introduce samples into the source of the DMS-MS platform. Here we describe the application of FIA-DMS-MS/MS for the analysis of urinary acylcarnitine species. More than 20 acylcarnitine species can be detected and quantified during a single FIA-DMS-MS/MS acquisition.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
Lapthorn C, Pullen F, Chowdhry BZ (2013) Ion mobility spectrometry-mass spectrometry (IMS-MS) of small molecules: separating and assigning structures to ions. Mass Spectrom Rev 32(1):43–71
Azzam EI, Jay-Gerin JP, Pain D (2012) Ionizing radiation-induced metabolic oxidative stress and prolonged cell injury. Cancer Lett 327(1–2):48–60
Barjaktarovic Z, Schmaltz D, Shyla A, Azimzadeh O, Schulz S, Haagen J, Dorr W, Sarioglu H, Schafer A, Atkinson MJ, Zischka H, Tapio S (2011) Radiation-induced signaling results in mitochondrial impairment in mouse heart at 4 weeks after exposure to X-rays. PLoS One 6(12):e27811
Pannkuk EL, Laiakis EC, Authier S, Wong K, Fornace AJ Jr (2015) Global metabolomic identification of long-term dose-dependent urinary biomarkers in nonhuman primates exposed to ionizing radiation. Radiat Res 184(2):121–133
Laiakis EC, Pannkuk EL, Chauthe SK, Wang YW, Lian M, Mak TD, Barker CA, Astarita G, Fornace AJ Jr (2017) A serum small molecule biosignature of radiation exposure from total body irradiated patients. J Proteome Res 16(10):3805–3815
Vera NB, Chen Z, Pannkuk E, Laiakis EC, Fornace AJ Jr, Erion DM, Coy SL, Pfefferkorn JA, Vouros P (2018) Differential mobility spectrometry (DMS) reveals the elevation of urinary acetylcarnitine in non-human primates (NHPs) exposed to radiation. J Mass Spectrom 53(7):548–559
Chen Z, Coy SL, Pannkuk EL, Laiakis EC, Fornace AJ Jr, Vouros P (2018) Differential mobility spectrometry-mass spectrometry (DMS-MS) in radiation biodosimetry: rapid and high-throughput quantitation of multiple radiation biomarkers in nonhuman primate urine. J Am Soc Mass Spectrom 29(8):1650–1664
Kafle A, Coy SL, Wong BM, Fornace AJ Jr, Glick JJ, Vouros P (2014) Understanding gas phase modifier interactions in rapid analysis by differential mobility-tandem mass spectrometry. J Am Soc Mass Spectrom 25(7):1098–1113
Heinig K, Henion J (1999) Determination of carnitine and acylcarnitines in biological samples by capillary electrophoresis-mass spectrometry. J Chromatogr B Biomed Sci Appl 735(2):171–188
Schneider BB, Nazarov EG, Londry F, Vouros P, Covey TR (2016) Differential mobility spectrometry/mass spectrometry history, theory, design optimization, simulations, and applications. Mass Spectrom Rev 35(6):687–737
Acknowledgments
This work was funded by the Internal Medicine Research Unit (IMRU), within the Pfizer Global Research and Development Business Unit, at Pfizer.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Science+Business Media, LLC, part of Springer Nature
About this protocol
Cite this protocol
Vera, N.B., Clasquin, M., Coy, S.L., Vouros, P. (2020). The Use of DMS-MS for the Quantitative Analysis of Acylcarnitines. In: Paglia, G., Astarita, G. (eds) Ion Mobility-Mass Spectrometry . Methods in Molecular Biology, vol 2084. Humana, New York, NY. https://doi.org/10.1007/978-1-0716-0030-6_5
Download citation
DOI: https://doi.org/10.1007/978-1-0716-0030-6_5
Published:
Publisher Name: Humana, New York, NY
Print ISBN: 978-1-0716-0029-0
Online ISBN: 978-1-0716-0030-6
eBook Packages: Springer Protocols