Abstract
In Spiral computed tomography (CT) single scans separated by interscan pauses are replaced by a continuous data acquisition with continuous table movement (Kalender et al. 1990). This volume scanning that needs less than 1 min requires new modalities of i. v. contrast medium administration. There are many earlier experience on bolus administration of contrast medium in sequential CT (Claussen and Lochner 1983; Foley 1989; Kloeppel and Wittek 1985; Krahe et al. 1985; Partanen et al. 1984) that should be used for spiral CT. There are only few studies on spiral CT (Bautz et al. 1992; Galanski et al. 1992; Heike et al. 1993; HeImberger et al. 1993; Honda et al. 1992; Lenz et al. 1993; Marchal et al. 1991; Marchal and Baert 1992; ZWickeret al. 1993). The present study will be focussed on the transition between the initial and the continuous enhancement in upper abdomen.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Bautz W, Helmberger H, Strotzer M, Lenz M, Gerhardt P (1992) Spiral CT in the Preoperative Evaluation of Vessels of the Upper Abdomen. In: Felix R, Langer M (eds.) Advances in CT II. Springer, Berlin p. 117–123
Claussen C, Lochner B (1983) Dynamische Computertomographie. Springer, Berlin Heidelberg New York
Foley WD (1989) Dynamic hepatic CT. Radiology 170:617–622
Galanski M, Prokop M, Chavan A, Schaefer CM, Nschelsky JE (1992) Spiral volumetric CT as a new screening tool for renal artery stenosis. Radiology 185:181
Heiken JP, Brink JA, Vannier MW (1993) Spiral (Helical) CT. Radiology 189:647–656
Helmberger H, Baute W, Vogel U, Lenz M (1993) CT-Arterioportographie in Spiraltechnik zum Nachweis von Lebermetastasen. Fortschr. Roentgenstr. 158:410–415
Honda H, Matsuura Y, Onitsuka H, Murakami J, Kaneko K, Murayama S, Kanematsu T, Masuda K (1992) Differential Diagnosis of Hepatic Tumors (Hepatoma, Hemangioma and Metastasis) with CT: Value of Two-Phase Incremental Imaging. AJR 159:735–740
Kalender WA, Vock P, Polcin A, Soucek M (1990) Spiral-CT: Eine neue Technik für Volumenaufnahmen. I. Grundlagen und Methodik. Röntgenpraxis 43:323–330
Kloeppel R, Wittek W (1985) Beitrag zur Injektionstechnik des Kontrastmittelbolus für die Serien-CT. Radiol. diagn. 26:375–380
Krahe B, Harder T, Lackner K (1985) Seriencomputertomographie — Wertigkeit densitometrischer Messungen in der Diagnostik benigner und maligner Läsionen von Leber, Pankreas und Niere. Fortschr. Roentgenstr. 143:28–35
Lenz M, Wunderlich AP, Helmberger H, Gross M (1993) Spiral-CT bei Aortenaneurysmen. Fortschr. Roentgenstr. 158:393–404
Marchal G, Rigauts H, Baert AL (1991) Improved contrast enhancement of the pancreas by spiral scanning. Europ. J Radiol. 11:221–224
Marchal G, Baert AL (1992) Dynamic CT of the liver. Radiologe 32:211–216
Partanen K, Soimakallio S, Kivimäki T, Syrjänen K, Kormano M (1984) Dynamic topography of the Contrast Enhancement of the Spleen. Europ. J. Radiol. 4:101–106
Zwicker C, Langer M, Langer R, Keske U (1993) Bolusapplikation in der Spiral-CT des Oberbauches. Akt. Radiol. 3:172–176
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1994 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Kloeppel, R., Nitzsche, T., Koesling, S., Schulz, H.G. (1994). Improved Administration of Contrast Medium in Spiral Computed Tomography. In: Pokieser, H., Lechner, G. (eds) Advances in CT III. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-79116-1_14
Download citation
DOI: https://doi.org/10.1007/978-3-642-79116-1_14
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-79118-5
Online ISBN: 978-3-642-79116-1
eBook Packages: Springer Book Archive