Aortic Aneurysm Sac Shrinkage after Endovascular Repair Is Device–dependent: A Comparison of Zenith and AneuRx Endografts

  • Published:
Annals of Vascular Surgery

Aneurysm sac shrinkage after endovascular aneurysm repair (EAR) provides objective evidence of successful aneurysm exclusion and absence of endotension. Attainment of this outcome parameter may be device-dependent. In this study, 169 patients underwent EAR with an AneuRx (n = 118) or Zenith (n = 51) endograft at a single institution. A prospectively maintained database was examined for significant changes in aneurysm sac diameter (?5 mm) on the basis of computed tomography (CT) measurements at 6 and 12 months follow-up. Significant aneurysm sac shrinkage (?5 mm) occurred in 73.1 % (19/26) vs. 43.1% (28/65) of patients in the Zenith and AneuRx groups, respectively, at 12 months (p = 0.03). At 6 months follow-up, sac shrinkage rates were 51.4% (19/37) vs. 25.8% (16/62) in the Zenith and AneuRx groups, respectively (p = 0.04). Mean reduction of sac diameter at 12 months was -7.6 ± 1.6 mm vs. -3.5 ± 0.8 mm in the Zenith and AneuRx groups, respectively (p = 0.01). There was a trend toward fewer Type I and III endoleaks at 1 month in the Zenith group (0 vs. 8.3%) that did not achieve statistical significance (p = 0.067). The presence of any endoleak (³ 1 month) was associated with reduced 12 month shrink rates from 47.1% (25/51) to 28% (4/14) in the AneuRx group (p = 0.35) and from 77.3% (17/22) to 50% (2/4) in the Zenith group (p = 0.25). Patients treated with the Zenith endograft demonstrated a significantly higher rate and amount of aneurysm sac shrinkage than patients treated with an AneuRx device. Endoleaks appeared to negatively influence shrink rates with both endografts.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

About this article

Cite this article

Sternbergh, W., Conners, M., Tonnessen, B. et al. Aortic Aneurysm Sac Shrinkage after Endovascular Repair Is Device–dependent: A Comparison of Zenith and AneuRx Endografts . Ann Vasc Surg 17, 49–53 (2003). https://doi.org/10.1007/s10016-001-0334-y

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10016-001-0334-y

Keywords

Navigation