Coded Excitation of the Fundamental Flexural Guided Wave in Coated Bone Phantoms

  • Conference paper
  • First Online:
6th International Conference on the Development of Biomedical Engineering in Vietnam (BME6) (BME 2017)

Part of the book series: IFMBE Proceedings ((IFMBE,volume 63))

Abstract

There is an increasing interest of using ultrasonic guided waves to assess long cortical bones. In particular, a method of ultrasonic estimation of cortical thickness based on the fundamental flexural guided wave (FFGW), generally consistent with the A0 Lamb mode, has proven to be promising in vitro and modeling studies. Soft-tissue coating on top of the bone makes, however, the related in vivo application challenge. Visibility of FFGW on top of the soft tissue is not good due to the characteristic displacement profile of this mode, and due to its relatively high attenuation in the bone and surrounding tissue. Moreover, the soft tissue provides a direct propagation path for ultrasonic modes that give rise to interferences. As a result, the effective signal-to-noise ratio (SNR) of FFGW becomes low, and it is thus difficult to identify and extract this mode on top of the coating. So as to improve the FFGW detection, a tailored excitation of the ultrasound signal is introduced. To this end, the suitability of a base-sequence modulated Golay code (BSGC) is investigated on coated (2.5 mm) tubular bone phantoms with a wall thickness of 1.0–5.0 mm. The proposed approach improved the SNR, so that FFGW excitation by a custom-made 200-kHz piezo transducer was enabled at very low ultrasonic frequencies (67 kHz) and with much higher amplitude. This method facilitated the detection of thickness sensitivity of the FFGW phase velocity through the soft coating. These results indicate that BSGC excitation may also facilitate FFGW-based in vivo estimation of cortical thickness.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Moilanen P (2008) Ultrasonic guided waves in bone. IEEE Trans Ultrason Ferroelectr Freq Control 55:1277–1286

    Article  Google Scholar 

  2. Laugier P, Talmant M, Pham T (2008) Quo vadis, ultrasonics of bone? Present state and future trends. Arch Acoust 33:553–564

    Google Scholar 

  3. Laugier P (2008) Instrumentation for in vivo ultrasonic characterization of bone strength. IEEE Trans Ultrason Ferroelectr Freq Control 55:1179–1196

    Article  Google Scholar 

  4. Rico H (1997) The therapy of osteoporosis and the importance of cortical bone. Calcif Tissue Int 61(6):431–432

    Article  Google Scholar 

  5. Camus E, Talmant M, Berger G, Laugier P (2010) Analysis of the axial transmission technique for the assessment of skeletal status. J Acoust Soc Am 108:3058–3065

    Article  Google Scholar 

  6. Bossy E, Talmant M, Peyin F, Akrout L, Cloetens P, Laugier P (2004) An in vitro study of the ultrasonic axial transmission technique at the radius: 1-MHz velocity measurements are sensitive to both mineralization and intracortical porosity. J Bone Miner Res 19(9):1548–1556

    Article  Google Scholar 

  7. Bossy E, Talmant M, Laugier P (2002) Effect of bone cortical thickness on velocity measurements using ultrasonic axial transmission: a 2D simulation study. J Acoust Soc Am 112:297–307

    Article  Google Scholar 

  8. Bossy E, Talmant M, Defontaie M, Patat F, Laugier P (2004) Bidirectional axial transmission can improve accuracy and precision of ultrasonic velocity measurement in cortical bone: a validation on test materials. IEEE Trans Ultrason Ferroelectr Freq Control 51:71–79

    Article  Google Scholar 

  9. Viktorov LA (1967) Rayleigh and Lamb waves. Plenum, New York

    Google Scholar 

  10. Nicholson PHF, Moilanen P, Karkkainen T, Timonen J, Cheng S (2002) Guided ultrasonic waves in long bones: modelling, experiment and in vivo application. Physiol Meas 23:755–768

    Google Scholar 

  11. Ta DA, Huang K, Wang WQ, Wang YY, Le LH (2006) Identification and analysis of multimode guided waves in tibia cortical bone. Ultrasonics 44:e279–e284

    Article  Google Scholar 

  12. Moilanen P, Nicholson PHF, Kilappa V, Cheng S, Timonen J (2007) Assessment of the cortical bone thickness using ultrasonic guided waves-modeling and in vitro study. Ultrasound Med Biol 33:254–267

    Article  Google Scholar 

  13. Nunez I, Ing R, Negreira C, Fink M (2000) Transfer and green functions based on modal analysis for Lamb waves generation. J Acoust Soc Am 107(5):2370–2378

    Article  Google Scholar 

  14. Cook CE, Siebert WM (1988) The early history of pulse compression radar. IEEE Trans Aero Electron Sys 24:825–833

    Article  Google Scholar 

  15. Folegot T, Rosny J, prada C, Fink M (2005) Adaptive instant record signals applied to detection with time reversal operator decomposition. J Acoust Soc Am 117:3757–3765

    Google Scholar 

  16. Golay MJE (1961) Complementary series. IRE Trans Inf Theory 7:82–87

    Article  MathSciNet  Google Scholar 

  17. Chiao R, Hao X (2005) Coded excitation for diagnostic ultrasound: a system developer’s perspective. IEEE Trans Ultrason Ferroelectr Freq Control 52:160–170

    Article  Google Scholar 

  18. Song X, Ta D, Wang W (2012) A base sequence modulated Golay code improves the excitation and measurement of ultrasonic guided waves in long bones. IEEE Trans Ultrason Ferroelectr Freq Control 59:2580–2583

    Google Scholar 

  19. Moilanen P, Talment M, Nicholson PHF, Cheng S, Timonen J, Laugier P (2007) Ultrasonically determined thickness of long cortical bones: three-dimensional simulations of in vitro experiments. J Acoust Soc Am 122:2439–2445

    Article  Google Scholar 

Download references

Acknowledgements

This work was supported by the NSFC (Nos. 11174060, 11404207 and 11327405), the Science and Technology Support Program of Shanghai (13441901900), the Ph.D. Programs Foundation of the Ministry of Education of China (20130071110020), the Academy of Finland (Nos. 133183, 135069 and 135211) and European Regional Development Funds.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to X. Song .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Nature Singapore Pte Ltd.

About this paper

Cite this paper

Song, X., Moilanen, P., Ta, D. (2018). Coded Excitation of the Fundamental Flexural Guided Wave in Coated Bone Phantoms. In: Vo Van, T., Nguyen Le, T., Nguyen Duc, T. (eds) 6th International Conference on the Development of Biomedical Engineering in Vietnam (BME6) . BME 2017. IFMBE Proceedings, vol 63. Springer, Singapore. https://doi.org/10.1007/978-981-10-4361-1_3

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-4361-1_3

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-4360-4

  • Online ISBN: 978-981-10-4361-1

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics