Skip to main content

Long Cortical Bone Fracture Evaluation Using Ultrasonic Guided Waves: A Tubular Phantom Study

  • Conference paper
  • First Online:
6th International Conference on the Development of Biomedical Engineering in Vietnam (BME6) (BME 2017)

Part of the book series: IFMBE Proceedings ((IFMBE,volume 63))

Abstract

Mode conversion theory seems to be promising for interpretation of the guided mode propagation in the fractured and healing long bone. In the study, long cortical bone was modelled as a tubular structure and the transmission characteristics of two fundamental longitudinal modes L(0,1) and L(0,2) were investigated by axial transmission method. Acrylic pipes were involved as the bone phantoms in the experiments. To imitate different fracture statuses, artificial notches were circumferentially sawed on the phantom pipes with varying fracture depth from 0 to 80% of the thickness. In parallel to the experiments, numerical simulations were performed using three-dimension finite-difference time-domain (3D-FDTD) method. Mode interaction between the longitudinal modes L(0,1) and L(0,2) was quantified by the energy percentage parameters. Both numerical simulation and phantom experiment indicated that the longitudinal mode conversion correlated strongly with fracture depth, which may offer great potentials for the long bone fracture evaluation.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Barbieri G, Barbieri CH, Mazzer N et al (2011) Ultrasound propagation velocity and broadband attenuation can help evaluate the healing process of an experimental fracture. J Orthop Res 29:444–451

    Article  Google Scholar 

  2. Machado CB, Pereira W, Granke M et al (2011) Experimental and simulation results on the effect of cortical bone mineralization in ultrasound axial transmission measurements: a model for fracture healing ultrasound monitoring. Bone 48:1202–1209

    Article  Google Scholar 

  3. Protopappas VC, Vavva MG, Fotiadis DI et al (2008) Ultrasonic monitoring of bone fracture healing. IEEE Trans UFFC 55:1243–1255

    Article  Google Scholar 

  4. Xu K, Ta D, He R et al (2014) Axial transmission method for long bone fracture evaluation by ultrasonic guided waves: simulation, phantom and in vitro experiments. Ultrasound Med Biol 40:817–827

    Article  Google Scholar 

  5. Gheduzzi S, Dodd SP, Miles AW et al (2009) Numerical and experimental simulation of the effect of long bone fracture healing stages on ultrasound transmission across an idealized fracture. J Acoust Soc Am 126:887–894

    Article  Google Scholar 

  6. Dodd SP, Cunningham JL, Miles AW et al (2008) Ultrasound transmission loss across transverse and oblique bone fractures: an in vitro study. Ultrasound Med Biol 34:454–462

    Article  Google Scholar 

  7. Moilanen P (2008) Ultrasonic guided waves in bone. IEEE Trans UFFC 55:1277–1286

    Article  Google Scholar 

  8. Talmant M, Foiret J, Minonzio JG (2011) Guided waves in cortical bone. in bone quantitative ultrasound, Springer, Dordrecht, Heidelberg, London, New York, pp 147–179

    Google Scholar 

  9. Xu K, Ta D, Su Z et al (2014) Transmission analysis of ultrasonic Lamb mode conversion in a plate with partial-thickness notch. Ultrasonics 54:395–401

    Article  Google Scholar 

  10. Xu K, Liu D, Ta D, Hu B et al (2014) Quantification of guided mode propagation in fractured long bones. Ultrasonics 54:1210–1218

    Article  Google Scholar 

Download references

Acknowledgements

This work was supported by the NSFC (11304043, 11327405, 11525416), NSFC-CNRS-PICS (11511130133) the CNRS PICS programme (07032), and the Foundation pour la Recherche Medicale (FRM DBS201311228444).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kailiang Xu .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Nature Singapore Pte Ltd.

About this paper

Cite this paper

Xu, K., Ta, D., Minonzio, J.G., Laugier, P., Wang, W. (2018). Long Cortical Bone Fracture Evaluation Using Ultrasonic Guided Waves: A Tubular Phantom Study. In: Vo Van, T., Nguyen Le, T., Nguyen Duc, T. (eds) 6th International Conference on the Development of Biomedical Engineering in Vietnam (BME6) . BME 2017. IFMBE Proceedings, vol 63. Springer, Singapore. https://doi.org/10.1007/978-981-10-4361-1_22

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-4361-1_22

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-4360-4

  • Online ISBN: 978-981-10-4361-1

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics