Skip to main content

Anterior Cerebral Artery (A1 Segment) Aneurysm: Giant Partially Thrombosed A1 Aneurysm with Mass Effect, Treated with a Pipeline Embolization Device, Complete Resolution of the Mass Effect, and Modification of the Shape of the Implant During Long-Term Follow-Up

  • Living reference work entry
  • First Online:
The Aneurysm Casebook

Abstract

A giant A1 aneurysm exerting mass effect which was displacing both A1 arteries was found in a 64-year-old male patient who had presented with headaches and diplopia. The patient was treated with a Pipeline Embolization Device with good clinical and angiographic outcomes, with the singularity that the device changed shape as the mass effect from the aneurysm diminished. Actually, management of unruptured giant intracranial aneurysms is a matter of controversy among the neurovascular community. Several endovascular strategies have been used, such as stent-assisted coiling, flow diversion, and flow diversion and coils, with varying occlusion and complication rates reported. In this chapter, we present a case which shows the feasibility of using just one flow diverter stent as a sole treatment method for giant aneurysms. The various therapeutic options for treating of giant aneurysms are the main topic of this chapter.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

References

  • Becske T, Kallmes DF, Saatci I, McDougall CG, Szikora I, Lanzino G, Moran CJ, Woo HH, Lopes DK, Berez AL, Cher DJ, Siddiqui AH, Levy EI, Albuquerque FC, Fiorella DJ, Berentei Z, Marosfoi M, Cekirge SH, Nelson PK. Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial. Radiology. 2013;267(3):858–68. https://doi.org/10.1148/radiol.13120099. Epub 2013 Feb 15.

    Article  Google Scholar 

  • Becske T, Brinjikji W, Potts MB, Kallmes DF, Shapiro M, Moran CJ, Levy EI, McDougall CG, Szikora I, Lanzino G, Woo HH, Lopes DK, Siddiqui AH, Albuquerque FC, Fiorella DJ, Saatci I, Cekirge SH, Berez AL, Cher DJ, Berentei Z, Marosfoi M, Nelson PK. Long-term clinical and angiographic outcomes following pipeline embolization device treatment of complex internal carotid artery aneurysms: five-year results of the Pipeline for Uncoilable or Failed Aneurysms trial. Neurosurgery. 2017;80(1):40–8. https://doi.org/10.1093/neuros/nyw014.

    Article  PubMed  Google Scholar 

  • Dehdashti AR, Le Roux A, Bacigaluppi S, Wallace MC. Long-term visual outcome and aneurysm obliteration rate for very large and giant ophthalmic segment aneurysms: assessment of surgical treatment. Acta Neurochir. 2012;154(1):43–52. https://doi.org/10.1007/s00701-011-1167-2.

    Article  PubMed  Google Scholar 

  • Hammoud D, Gailloud P, Olivi A, Murphy KJ. Acute vasogenic edema induced by thrombosis of a giant intracranial aneurysm: a cause of pseudostroke after therapeutic occlusion of the parent vessel. AJNR Am J Neuroradiol. 2003;24(6):1237–9.

    PubMed  Google Scholar 

  • Henkes H, Fischer S, Liebig T, Weber W, Reinartz J, Miloslavski E, Kühne D. Repeated endovascular coil occlusion in 350 of 2759 intracranial aneurysms: safety and effectiveness aspects. Neurosurgery. 2008;62(6 Suppl 3):1532–7. https://doi.org/10.1227/01.neu.0000333815.79777.3b.

    Article  PubMed  Google Scholar 

  • Kulcsár Z, Houdart E, Bonafé A, Parker G, Millar J, Goddard AJ, Renowden S, Gál G, Turowski B, Mitchell K, Gray F, Rodriguez M, van den Berg R, Gruber A, Desal H, Wanke I, Rüfenacht DA. Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment. AJNR Am J Neuroradiol. 2011;32(1):20–5. https://doi.org/10.3174/ajnr.A2370.

    Article  PubMed  Google Scholar 

  • Lonjon M, Pennes F, Sedat J, Bataille B. Epidemiology, genetic, natural history and clinical presentation of giant cerebral aneurysms. Neurochirurgie. 2015;61(6):361–5. https://doi.org/10.1016/j.neuchi.2015.08.003.

    Article  CAS  PubMed  Google Scholar 

  • Lylyk P, Miranda C, Ceratto R, Ferrario A, Scrivano E, Luna HR, Berez AL, Tran Q, Nelson PK, Fiorella D. Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience. Neurosurgery. 2009;64(4):632–42. https://doi.org/10.1227/01.NEU.0000339109.98070.65; discussion 642-3; quiz N6

    Article  PubMed  Google Scholar 

  • Piano M, Valvassori L, Quilici L, Pero G, Boccardi E. Midterm and long-term follow-up of cerebral aneurysms treated with flow diverter devices: a single-center experience. J Neurosurg. 2013;118(2):408–16. https://doi.org/10.3171/2012.10.JNS112222.

    Article  PubMed  Google Scholar 

  • Szikora I, Marosfoi M, Salomváry B, Berentei Z, Gubucz I. Resolution of mass effect and compression symptoms following endoluminal flow diversion for the treatment of intracranial aneurysms. AJNR Am J Neuroradiol. 2013;34(5):935–9. https://doi.org/10.3174/ajnr.A3547.

    Article  CAS  PubMed  Google Scholar 

  • Turowski B, Macht S, Kulcsár Z, Hänggi D, Stummer W. Early fatal hemorrhage after endovascular cerebral aneurysm treatment with a flow diverter (SILK-stent): do we need to rethink our concepts? Neuroradiology. 2011;53(1):37–41. https://doi.org/10.1007/s00234-010-0676-7.

    Article  PubMed  Google Scholar 

  • van Rooij WJ, Sluzewski M. Unruptured large and giant carotid artery aneurysms presenting with cranial nerve palsy: comparison of clinical recovery after selective aneurysm coiling and therapeutic carotid artery occlusion. AJNR Am J Neuroradiol. 2008;29(5):997–1002. https://doi.org/10.3174/ajnr.A1023.

    Article  PubMed  Google Scholar 

  • Wiebers DO, Whisnant JP, Huston J 3rd, Meissner I, Brown RD Jr, Piepgras DG, Forbes GS, Thielen K, Nichols D, O’Fallon WM, Peacock J, Jaeger L, Kassell NF, Kongable-Beckman GL, Torner JC. International Study of Unruptured Intracranial Aneurysms Investigators. Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment. Lancet. 2003;362(9378):103–10.

    Article  Google Scholar 

  • Zanaty M, Jabbour PM, Bou Sader R, Chalouhi N, Tjoumakaris S, Rosenwasser RH, Fernando Gonzalez L. Intra-aneurysmal thrombus modification after flow-diversion. J Clin Neurosci. 2015;22(1):105–10. https://doi.org/10.1016/j.jocn.2014.05.033.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Rene Viso .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this entry

Check for updates. Verify currency and authenticity via CrossMark

Cite this entry

Viso, R., Lylyk, I., Perez, N., Scrivano, E., Lylyk, P. (2020). Anterior Cerebral Artery (A1 Segment) Aneurysm: Giant Partially Thrombosed A1 Aneurysm with Mass Effect, Treated with a Pipeline Embolization Device, Complete Resolution of the Mass Effect, and Modification of the Shape of the Implant During Long-Term Follow-Up. In: Henkes, H., Lylyk, P., Ganslandt, O. (eds) The Aneurysm Casebook. Springer, Cham. https://doi.org/10.1007/978-3-319-70267-4_150-1

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-70267-4_150-1

  • Received:

  • Accepted:

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-70267-4

  • Online ISBN: 978-3-319-70267-4

  • eBook Packages: Springer Reference MedicineReference Module Medicine

Publish with us

Policies and ethics