Skip to main content

Convenient Nipple Splint Using Aquaplast Thermoplastic (Optimold) After Surgical Correction of the Inverted Nipple

  • Chapter
  • First Online:

Abstract

The recurrence of surgically corrected inverted nipple is not uncommon in various techniques. To prevent it from sinking again, postoperative suspension of the pulled up nipple is a useful supportive method. But the discomfort of attaching the suspension device is troublesome. A comfortable nipple suspension device using a heat-malleable material of Aquaplast Thermoplastic (Optimold) was newly designed. A sheet of Optimold was tailored into a proper size. Using its plasticity in hot water, it was manually molded into “Ω” shape. After acquiring proper projection from the retracted nipple regardless of operation techniques, it was applied on the nipple-areolar complex as a nipple splint. The raised nipple was suspended on it using two traction sutures with 3-0 nylon piercing the top of the nipple. Then, those were tied on the roof of the splint and maintained for 7 days. This method is simple, effective, and comfortable.

This is a preview of subscription content, log in via an institution.

References

  1. Lee TJ, Kim WR. Nipple Suspension Using biopsy bottle after surgical correction for inverted nipple. J Korean Soc Aesthet Plast Reconstr Surg. 2004;10(2):115–7.

    Google Scholar 

  2. Han SH, Hong YG. The inverted nipple: its grading and surgical correction. Plast Reconstr Surg. 1999;104(2):389–95.

    Article  CAS  PubMed  Google Scholar 

  3. Kurihara K, Maexawa N, Yanagawa H, Imai T. Surgical correction of the inverted nipple with a tendon graft: Hammock procedure. Plast Reconstr Surg. 1990;86(5):999–1003.

    Article  CAS  PubMed  Google Scholar 

  4. Kim JK, SC Y. Convenient nipple suspension method using Aquaplast Thermoplastic (Optimold) Splint after surgical correction of inverted nipple. J Korean Soc Aesthet Plast Reconstr Surg. 2007;13(1):89–91.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Seong Cheol Yu M.D., Ph.D. .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer International Publishing AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Yu, S. (2018). Convenient Nipple Splint Using Aquaplast Thermoplastic (Optimold) After Surgical Correction of the Inverted Nipple. In: Shiffman, M. (eds) Nipple-Areolar Complex Reconstruction. Springer, Cham. https://doi.org/10.1007/978-3-319-60925-6_40

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-60925-6_40

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-60924-9

  • Online ISBN: 978-3-319-60925-6

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics