Skip to main content

Calibration of Scanning Electron Microscope with Improved Model of the Silicon Relief Measure

  • Conference paper
  • First Online:
  • 2239 Accesses

Part of the book series: Advances in Intelligent Systems and Computing ((AISC,volume 550))

Abstract

Accuracy of measurements with scanning electron microscope (SEM) depends on the environment conditions, noises in nanometer-ranges (caused by non-ideal surface of measures), non-ideal SEM design, influence of external factors (vibration, acoustic noise, magnetic fields, etc.). To reduce the influence of these variables, the calibration procedure, with the use of silicon measures to reproduce dimensions is performed preferably. The model of measure real image (which is used for calibration) can be formalized as the convolution of the level of secondary electron emission and the distribution of electrons in the crossover of the electron probe. Based on the developed model, the general approach to SEM calibration is formulated and proved. The step by step removal of non-parametric and parametric uncertainty of scale factor and electron probe equivalent diameter is proposed. As the first step, the approximation of individual cuts on the measured object image, which correspond to the same cuts of measure relief with further averaging and estimating the metrological parameters and their error distributions, is performed. In the second step (of optimal estimation), the vector containing metrological characteristics using Bayesian criterion and the theory of optimal estimations is find. Proposed approach can significantly increase SEM accuracy and performance.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Frase, C.G., et al.: Nanoscale Calibration Standards and Methods: Dimensional and Related Measurements in the Micro- and Nanometer Range. Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim (2005)

    Google Scholar 

  2. Volodarski, E., Koshewa, L., Warsza, Z., Shantyr, A.: O kalibracji elektronowego mikroskopu skaningowego do pomiaru wymiarów w zakresie nanometrowym. Elektronika 2, 64–67. (in Polish)

    Google Scholar 

  3. Bulygin, F.V., Lyaskovskii, V.L.: An investigation of methods of measuring the diameter of the electron probe of scanning electron microscopes using modern nanometer band standard measures. Meas. Tech. 53(9), 996–1001 (2010). Translated from Metrologiya (Russ.) 7, 34–43 (2010)

    Article  Google Scholar 

  4. Danilova, M.A., Mityukhlyaev, V.B., Novikov, Y.A., et al.: A test object with three certified linewidth dimensions for a scanning electron microscope. Meas. Tech. 51(9), 98–1003 (2008). Translated from Izmeritel’naya Tekhnika (Russ.) 9 49–52 (2008)

    Article  Google Scholar 

  5. Reimer, L.: Image Formation in Low-Voltage Scanning Electron Microscopy, p. 144. SPIE, Washington (1993)

    Google Scholar 

  6. Clough, F.J., Paula, S.: A technique to investigate inhomogeneity in materials: an arrangement of microchip and scanning electron microscope. Rev. Sci. Instrum. 72(9), 3543–3545 (2001)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Anton Shantyr .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2017 Springer International Publishing AG

About this paper

Cite this paper

Shantyr, A., Volodarski, E., Warsza, Z.L. (2017). Calibration of Scanning Electron Microscope with Improved Model of the Silicon Relief Measure. In: Szewczyk, R., Zieliński, C., Kaliczyńska, M. (eds) Automation 2017. ICA 2017. Advances in Intelligent Systems and Computing, vol 550. Springer, Cham. https://doi.org/10.1007/978-3-319-54042-9_44

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-54042-9_44

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-54041-2

  • Online ISBN: 978-3-319-54042-9

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics