Abstract
Lightning is a natural phenomenon which occurred when the upper atmosphere becomes unstable due to rising air currents. Lightning can be one of the natural causes of human injuries or damage to electrical equipment. In order to create a system to protect buildings from this natural phenomenon, the Lightning Protection System (LPS) was introduced. However, various problems have been associated with this conventional method. A common problem related to external lightning protection cables is corrosion. Therefore, the newly arrangement of lightning protection cable was proposed and investigated. Galvanized steel cable was used in this research due to suitability of the materials to be embedded inside reinforced concrete beam. Load-displacement behavior from the three (3) point flexural test was compared with the finding from the Finite Element Analysis (FEA). From the result, FEA showed slightly higher than experiment result at the maximum load.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
British Standard (BS) (2000) Eurocode EN 12390-5. Testing for hardened concrete. Part 5: flexural strength of tests specimen. British Standard Institution, UK
British Standard (BS) (2004) Design of concrete structures, part 1-1: general rules and rules for buildings. British Standard Institution, UK
Ghavamian A, Maghami MR, Dehghan S, Gomes C (2015) Concerns of corrosive effects with respect to lightning protection systems. Eng Fail Anal 57:434–443
Larter SC (2013) Galvanic corrosion in lightning protection applications—problems & solutions. Warren Lightning Rod Company
Leite DM, Sueta HEB, Geraldo FG, José AB (2007) Accidents reduction in Brazil due to of lightning: adopted solutions according to the IEC1024-1 standard and IEC62305 series. Paper presented at the proceedings of the IX international symposium on lightning protection, Foz do Iguaçu
Malaysia PWD (2011) Specification for lightning protection system for structures L-S9. Cawangan Kejuruteraan Elektrik Jabatan Kerja Raya Malaysia
Mustaqqim et al (2018) The natural frequency analysis of reinforced concrete beam with additional of lightning protection cable. Malays Constr Res J (MCRJ) 4(2)
Acknowledgements
This research was funded by School of Housing Building and Planning Contract Research Grant (401/PPBGN/510059/I-124). The authors wish to extend appreciation to School of Housing Building and Planning Universiti Sains Malaysia and School of Environmental Engineering Universiti Malaysia Perlis.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this paper
Cite this paper
Abdul Rahim, M., Abdul Ghani, A.N., Che Munaaim, M.A., Md Ghazaly, Z. (2020). Load-Displacement Behaviors of Reinforced Concrete Beam Embedded with Galvanized Steel Cable: Comparison Between Experiment and Finite Element Analysis. In: Mohamed Nazri, F. (eds) Proceedings of AICCE'19. AICCE 2019. Lecture Notes in Civil Engineering, vol 53. Springer, Cham. https://doi.org/10.1007/978-3-030-32816-0_34
Download citation
DOI: https://doi.org/10.1007/978-3-030-32816-0_34
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-32815-3
Online ISBN: 978-3-030-32816-0
eBook Packages: EngineeringEngineering (R0)