Abstract
A common cause of loss of vision for humans is lens opacity, or cat aracts, which prevent patients from having a full field of vision and lower their visual acuities. Cataracts can be corrected for by replacing the opaque lens with a toric intraocular lens. The calculation for the placement of the toric lens is exceedingly important for the patient´s recovery of vision. Some houses, take date form medical equipment and perform the calculation, but more depends on the experience of the treating physician to ensure the desired effectiveness and efficiency, For this reason, in this investigation, the proposal is presented to perform the calculation, in addition, the approach to simulation of the placement of the lens inside the eye, especially in its axial length and depth in the anterior chamber, determinants for short, medium and long distance with an automatic focus and appropriate, in like manner, the results are exposed to the specialists of the clinic “Santa Lucia” in the city of Quito.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Mura, C.J.J.: Cirugía actual de la catarata. Revista Médica Clínica Las Condes 21(6), 912–919 (2010)
Tamez-Pena, A., Nava-García, J.A., Zaldívar-Orta, E.L., Lozano-Ramírez, J.F., Cadena-Garza, C.L., Hernández-Camarena, J.C., Valdez-García, J.E.: Efecto clínico de la rotación post- operatoria de los lentes intraoculares tóricos. Revista Mexicana de Oftalmología 89(4), 219–224 (2015)
Moreno, N.R., Srur, A.M., Nieme, B.C.: Cirugía refractiva: indicaciones, técnicas y resultados. Revista Médica Clínica Las Condes 21(6), 901–910 (2010)
Hernández, L.T.: Estudio de Técnicas Biométricas y cálculo de la lente intraocular, 6–7 (2010)
Gomez Lara, F.: Comparación de fórmulas biométricas en el cálculo de lentes intra- oculares mediante el uso biometría óptica (121), 20–21 (2013)
Prado-Serrano, A., Nava-Hernández, N.G.: Calculo del poder dióptrico de lentes intraoculares ¿Cómo evitar la sorpresa refractiva? Revista Mexicana de Oftalmologia 83(5), 272–280 (2009)
Carracedo, M., Mengual, M., Córdoba Delgado, S.: Lentes multifocales: una buena opción en la cirugía de catarata. Revista Cubana de Oftalmología 30(3), 1–14 (2007)
Haigis, W.: Corneal power after refractive surgery for myopia: contact lens method. J. Cataract Refract. Surg. 29, 1397–1411 (2003)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this paper
Cite this paper
Castillo-Cabrera, J., Pucha-Ortiz, N., Pinos-Velez, E., Ipanque, W., Chacón, C.L. (2020). Proposal for a Tool for the Calculation of Toric Intraocular Lens Using Multivariate Regression. In: Botto-Tobar, M., León-Acurio, J., Díaz Cadena, A., Montiel Díaz, P. (eds) Advances in Emerging Trends and Technologies. ICAETT 2019. Advances in Intelligent Systems and Computing, vol 1066. Springer, Cham. https://doi.org/10.1007/978-3-030-32022-5_22
Download citation
DOI: https://doi.org/10.1007/978-3-030-32022-5_22
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-32021-8
Online ISBN: 978-3-030-32022-5
eBook Packages: Intelligent Technologies and RoboticsIntelligent Technologies and Robotics (R0)