Abstract
Glass insulators are more susceptible to vandalism and the presence of broken units can modify the supportability of the insulator string. It is necessary to know the influence of broken insulators regarding to the quantity and position in the string to verify the supportability of the remaining units. The aim is to evaluate the electrical performance of glass insulator strings with broken units in AC systems, under pollution conditions, in various configurations. The artificial pollution method used will be the solid layer according to the recommendations of IEC-60507, considering three levels of pollution for each configuration. The SDD (salt deposit density) values used were: 0.03, 0.07 and 0.10 mg/cm2. In this work, 9 configurations were tested. The test was carried out under steam fog, applying the non-standardized method named RFO (Rapid Flashover), which has been used by some laboratories and proposed as an alternative to the up and down method. The tests identified that the position of the broken insulators in the string influences the breakdown voltage. The results show that glass insulator strings with broken units in random and intermediate positions may represent a more pronounced drop in the supportability when compared to the configurations in which these units are located at the ends, the one in which the broken units are close to the conductor presents the least loss of supportability.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Rawat, A., Gorur, R.: Microstructure based evaluation of Field aged and new porcelain suspension insulators. IEEE Trans. Dielectr. Electr. Insul. 16(1), 107–115 (2009)
Pressi, R.A., Resener, M., Ramos, M.: Economic evaluation of preventive inspections of transmission circuits through the emission of corona. In: Congreso Internacional de Distribuición Eléctrica, Buenos Aires, Argentina, 516 (2014)
George, J.M., Prat, S., Tartier, S., Lodi, Z.: Electrical characteristics and properties of a stub (damaged toughened glass insulator). In: 18th International Symposium on High Voltage Engineering, 25–30 August 2013, Seoul, Korea, paper OE1-03 (2013)
IEC 60507:2013 - Artificial pollution tests on high-voltage insulators to be used on A.C. systems (2013)
Lambeth, P.J.: Variable-voltage application for insulator pollution tests. IEEE Trans. Power Deliv. 3(4), 2103–2111 (1988)
Gutman, I.: Time-effective rapid test procedures for pollution testing of different types of insulators. In: INMR Conference (2015)
Vlastós, A.E., Feiju, Y., Boubitsas, V.: Clean fog rapid procedure test of artificially and naturally polluted HVDC porcelain barrel insulators. IEEE Trans. Power Deliv. 6(4), 1791–1797 (1991)
Cigré Technical Brochure nº 691 - Pollution Test of Naturally and Artificially Contaminated Insulators, July 2017
Jiang, X., et al.: Study on pollution flashover performance of short samples of composite insulators intended for ± 800 kV UHV DC. IEEE Trans. Dielectr. Electr. Insul. 14(5), 1192–1200 (2007)
Pigini, A.: Optimizing insulation design for harsh service environments. INMR article, 9 September 2018
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this paper
Cite this paper
de Souza Silva, F.T., Garcia, R.W.S. (2020). Evaluation of the Performance of Glass Insulator String with Broken Units Under Artificial Pollution. In: Németh, B. (eds) Proceedings of the 21st International Symposium on High Voltage Engineering. ISH 2019. Lecture Notes in Electrical Engineering, vol 598. Springer, Cham. https://doi.org/10.1007/978-3-030-31676-1_34
Download citation
DOI: https://doi.org/10.1007/978-3-030-31676-1_34
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-31675-4
Online ISBN: 978-3-030-31676-1
eBook Packages: EngineeringEngineering (R0)