Skip to main content

Evaluation of the Performance of Glass Insulator String with Broken Units Under Artificial Pollution

  • Conference paper
  • First Online:
Proceedings of the 21st International Symposium on High Voltage Engineering (ISH 2019)

Part of the book series: Lecture Notes in Electrical Engineering ((LNEE,volume 598))

Included in the following conference series:

  • 2186 Accesses

Abstract

Glass insulators are more susceptible to vandalism and the presence of broken units can modify the supportability of the insulator string. It is necessary to know the influence of broken insulators regarding to the quantity and position in the string to verify the supportability of the remaining units. The aim is to evaluate the electrical performance of glass insulator strings with broken units in AC systems, under pollution conditions, in various configurations. The artificial pollution method used will be the solid layer according to the recommendations of IEC-60507, considering three levels of pollution for each configuration. The SDD (salt deposit density) values used were: 0.03, 0.07 and 0.10 mg/cm2. In this work, 9 configurations were tested. The test was carried out under steam fog, applying the non-standardized method named RFO (Rapid Flashover), which has been used by some laboratories and proposed as an alternative to the up and down method. The tests identified that the position of the broken insulators in the string influences the breakdown voltage. The results show that glass insulator strings with broken units in random and intermediate positions may represent a more pronounced drop in the supportability when compared to the configurations in which these units are located at the ends, the one in which the broken units are close to the conductor presents the least loss of supportability.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Rawat, A., Gorur, R.: Microstructure based evaluation of Field aged and new porcelain suspension insulators. IEEE Trans. Dielectr. Electr. Insul. 16(1), 107–115 (2009)

    Article  Google Scholar 

  2. Pressi, R.A., Resener, M., Ramos, M.: Economic evaluation of preventive inspections of transmission circuits through the emission of corona. In: Congreso Internacional de Distribuición Eléctrica, Buenos Aires, Argentina, 516 (2014)

    Google Scholar 

  3. George, J.M., Prat, S., Tartier, S., Lodi, Z.: Electrical characteristics and properties of a stub (damaged toughened glass insulator). In: 18th International Symposium on High Voltage Engineering, 25–30 August 2013, Seoul, Korea, paper OE1-03 (2013)

    Google Scholar 

  4. IEC 60507:2013 - Artificial pollution tests on high-voltage insulators to be used on A.C. systems (2013)

    Google Scholar 

  5. Lambeth, P.J.: Variable-voltage application for insulator pollution tests. IEEE Trans. Power Deliv. 3(4), 2103–2111 (1988)

    Article  Google Scholar 

  6. Gutman, I.: Time-effective rapid test procedures for pollution testing of different types of insulators. In: INMR Conference (2015)

    Google Scholar 

  7. Vlastós, A.E., Feiju, Y., Boubitsas, V.: Clean fog rapid procedure test of artificially and naturally polluted HVDC porcelain barrel insulators. IEEE Trans. Power Deliv. 6(4), 1791–1797 (1991)

    Article  Google Scholar 

  8. Cigré Technical Brochure nº 691 - Pollution Test of Naturally and Artificially Contaminated Insulators, July 2017

    Google Scholar 

  9. Jiang, X., et al.: Study on pollution flashover performance of short samples of composite insulators intended for ± 800 kV UHV DC. IEEE Trans. Dielectr. Electr. Insul. 14(5), 1192–1200 (2007)

    Google Scholar 

  10. Pigini, A.: Optimizing insulation design for harsh service environments. INMR article, 9 September 2018

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Frederico Tassi de Souza Silva .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

de Souza Silva, F.T., Garcia, R.W.S. (2020). Evaluation of the Performance of Glass Insulator String with Broken Units Under Artificial Pollution. In: Németh, B. (eds) Proceedings of the 21st International Symposium on High Voltage Engineering. ISH 2019. Lecture Notes in Electrical Engineering, vol 598. Springer, Cham. https://doi.org/10.1007/978-3-030-31676-1_34

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-31676-1_34

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-31675-4

  • Online ISBN: 978-3-030-31676-1

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics