Using the Photoplethysmography Technique to Improve the Accuracy of LVET Measurement in the ICG Technique

  • Conference paper
  • First Online:
  • 553 Accesses

Part of the book series: Smart Innovation, Systems and Technologies ((SIST,volume 110))

Abstract

The stroke volume is an important cardiac blood flow hydraulic parameter that can be used to assess whether the pump function of the heart is normal. Non-invasive stroke volume measurement is currently performed using impedance cardio plethysmography (ICG). The ICG method is used to detect the amount of changes in the volume of thoracic cavity generated by the heartbeat and to estimate the stroke volume. Left ventricular ejection time (LVET) is an important parameter in stroke volume measurement with ICG technology. However, the ICG signal is susceptible to artificial noise interference, which leads to inaccurate LVET and miscalculation of stroke volume. In order to solve this problem, this paper uses the photoplethysmography (PPG) sensor to measure LVET, and assesses whether the LVET measured by the PPG sensor is more accurate than the LVET measured by the ICG. The results show that using the PPG sensor can indeed improve the accuracy of the LVET measurement, and that the closer the PPG sensor is placed to the heart, the more stable and accurate the measured LVET will be.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   189.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   249.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   249.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Medical Encyclopedia - ‘Cardiogenic Shock’. http://big5.wiki8.com/xinyuanxingxiuke_101/. Accessed 19 July 2018

  2. Carr, J.J., Brown, J.M.: Introduction to Biomedical Equipment Technology. Prentice Hall, America (2001)

    Google Scholar 

  3. Kubicek, W.G., Karnegis, J.N., Patterson, R.P., et al.: Development and evaluation of an impedance cardiograph system. Aerosp. Med. 37, 1208–1212 (1966)

    Google Scholar 

  4. King, M.R., Anderson, T.A., Sui, J., Luo, H.G., et al.: The Use of non-invasive cardiac output monitoring to detect cardiac physiologic responses to hypoxia in pediatric patients under general anesthesia. In: Anesthesiology 2014 Annual Meeting Abstract Website (2014)

    Google Scholar 

  5. Hasija, S., Chauhan, S., Makhija, N.: Comparison of the hemodynamic effects of the induction agents ketamine, etomidate and sevoflurane using the model of electrical velocimetry based cardiac output monitoring in pediatric cardiac surgical patients. World J. Cardiovasc. Surg. 4, 167–175 (2014)

    Article  Google Scholar 

  6. DeMarzo, A.P.: Using impedance cardiography with postural change to stratify patients with hypertension. Ther. Adv. Cardiovasc. Dis. 5, 139–148 (2011)

    Article  Google Scholar 

  7. Branson, R.D., Mannheimer, P.D.: Forehead oximetry in critically ill patients: the case for a new monitoring sit. Respir. Care Clin. N. Am. 10, 359–367 (2004)

    Article  Google Scholar 

  8. Qu, M., Zhang, Y., Webster, J.G., Tompkins, W.J.: Motion artifact from spot and band electrodes during impedance cardiography. IEEE Trans. Biomed. Eng. 33, 1029–1036 (1986)

    Article  Google Scholar 

Download references

Acknowledgment

This research is in part funded by the Ministry of Science and Technology in Taiwan under grants MOST 106-2221-E-324-001. MOST106-2218-E-027-017.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tai-Shen Huang .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Liu, SH., Zhu, ZY., Lai, SH., Huang, TS. (2019). Using the Photoplethysmography Technique to Improve the Accuracy of LVET Measurement in the ICG Technique. In: Pan, JS., Ito, A., Tsai, PW., Jain, L. (eds) Recent Advances in Intelligent Information Hiding and Multimedia Signal Processing. IIH-MSP 2018. Smart Innovation, Systems and Technologies, vol 110. Springer, Cham. https://doi.org/10.1007/978-3-030-03748-2_22

Download citation

Publish with us

Policies and ethics