The stroke volume is an important cardiac blood flow hydraulic parameter that can be used to assess whether the pump function of the heart is normal. Non-invasive stroke volume measurement is currently performed using impedance cardio plethysmography (ICG). The ICG method is used to detect the amount of changes in the volume of thoracic cavity generated by the heartbeat and to estimate the stroke volume. Left ventricular ejection time (LVET) is an important parameter in stroke volume measurement with ICG technology. However, the ICG signal is susceptible to artificial noise interference, which leads to inaccurate LVET and miscalculation of stroke volume. In order to solve this problem, this paper uses the photoplethysmography (PPG) sensor to measure LVET, and assesses whether the LVET measured by the PPG sensor is more accurate than the LVET measured by the ICG. The results show that using the PPG sensor can indeed improve the accuracy of the LVET measurement, and that the closer the PPG sensor is placed to the heart, the more stable and accurate the measured LVET will be.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
Medical Encyclopedia - ‘Cardiogenic Shock’. http://big5.wiki8.com/xinyuanxingxiuke_101/. Accessed 19 July 2018
Carr, J.J., Brown, J.M.: Introduction to Biomedical Equipment Technology. Prentice Hall, America (2001)
Kubicek, W.G., Karnegis, J.N., Patterson, R.P., et al.: Development and evaluation of an impedance cardiograph system. Aerosp. Med. 37, 1208–1212 (1966)
King, M.R., Anderson, T.A., Sui, J., Luo, H.G., et al.: The Use of non-invasive cardiac output monitoring to detect cardiac physiologic responses to hypoxia in pediatric patients under general anesthesia. In: Anesthesiology 2014 Annual Meeting Abstract Website (2014)
Hasija, S., Chauhan, S., Makhija, N.: Comparison of the hemodynamic effects of the induction agents ketamine, etomidate and sevoflurane using the model of electrical velocimetry based cardiac output monitoring in pediatric cardiac surgical patients. World J. Cardiovasc. Surg. 4, 167–175 (2014)
DeMarzo, A.P.: Using impedance cardiography with postural change to stratify patients with hypertension. Ther. Adv. Cardiovasc. Dis. 5, 139–148 (2011)
Branson, R.D., Mannheimer, P.D.: Forehead oximetry in critically ill patients: the case for a new monitoring sit. Respir. Care Clin. N. Am. 10, 359–367 (2004)
Qu, M., Zhang, Y., Webster, J.G., Tompkins, W.J.: Motion artifact from spot and band electrodes during impedance cardiography. IEEE Trans. Biomed. Eng. 33, 1029–1036 (1986)
Acknowledgment
This research is in part funded by the Ministry of Science and Technology in Taiwan under grants MOST 106-2221-E-324-001. MOST106-2218-E-027-017.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this paper
Cite this paper
Liu, SH., Zhu, ZY., Lai, SH., Huang, TS. (2019). Using the Photoplethysmography Technique to Improve the Accuracy of LVET Measurement in the ICG Technique. In: Pan, JS., Ito, A., Tsai, PW., Jain, L. (eds) Recent Advances in Intelligent Information Hiding and Multimedia Signal Processing. IIH-MSP 2018. Smart Innovation, Systems and Technologies, vol 110. Springer, Cham. https://doi.org/10.1007/978-3-030-03748-2_22
Download citation
DOI: https://doi.org/10.1007/978-3-030-03748-2_22
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-03747-5
Online ISBN: 978-3-030-03748-2
eBook Packages: Intelligent Technologies and RoboticsIntelligent Technologies and Robotics (R0)