Skip to main content

Abstract

Penile prosthesis placement has remained a predictable and reliable treatment for erectile dysfunction for over two decades. Despite advances in prosthetic design and the use of more durable materials, mechanical problems with these devices may occur. In addition, weakness in the wall of the erectile bodies, the deposition of scar tissue in the penis, problems with blood supply, and the entrance of bacteria into the wound at the time of implant surgery have contributed to a suboptimal result in certain patients. Fortunately, as experience has been gained, the incidence of complications has decreased and the management of problems has become more timely and more gratifying.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Fallon B, Ghanem H. Sexual performance and satisfaction with penile prostheses in impotence of various etiologies. Int J Impotence Res 1990; 2: 35–42.

    Google Scholar 

  2. Mulcahy JJ. A technique for maintaining penile prosthesis position to prevent proximal migration. J Urol 1987; 17: 294–296.

    Google Scholar 

  3. Montague DK, Lakin MM. Early experience with the controlled girth and length expanding cylinder of the American Medical Systems Ultrex penile prosthesis. J Urol 1992; 148: 1444–1446.

    PubMed  CAS  Google Scholar 

  4. Wilson SK, Delk JR. The “S” deformity: a complication of AMS 700 ultrex penile prosthesis. Int J Impotence Res 1994; 6 (suppl 1): D168.

    Google Scholar 

  5. Wilson SK, Delk JR. A new treatment for Peyronie’s disease: modeling the penis over an inflatable penile prosthesis. J Urol 1994; 152: 1121–1123.

    PubMed  CAS  Google Scholar 

  6. Mulcahy JJ, Rowland RG. Tunica wedge excision to correct penile curvature associated with the inflatable penile prosthesis. J Urol 1987; 138: 63–64.

    PubMed  CAS  Google Scholar 

  7. Nesbit RM. Congenital curvature of the phallus: report of three cases with description of corrective operation. J Urol 1965; 93: 230–232.

    PubMed  CAS  Google Scholar 

  8. Steidl CS, Mulcahy JJ. Erosion of penile prosthesis: a complication of ureteral catheterization. J Urol 1989; 142: 736–739.

    Google Scholar 

  9. Fitch WP, Roddy T. Erosion of inflatable penile prosthesis reservoir into bladder. J Urol 1986; 136: 1080.

    PubMed  Google Scholar 

  10. Ball TP. Surgical repair of penile “SST” deformity. Urology 1980; 15: 603–604.

    Article  PubMed  Google Scholar 

  11. Parulkar BG, Lamb B, Vickers MA Jr. The detection of leakage in inflatable urinary devices (Abstract). J Urol 1994; 153: 358A (Abstr 519).

    Google Scholar 

  12. Kabalin JN, Kessler R. Infectious complications of penile prosthesis surgery. J Urol 1988; 139: 953–955.

    PubMed  CAS  Google Scholar 

  13. Montague DK. Periprosthetic infections. J Urol 1987; 138: 68–69.

    PubMed  CAS  Google Scholar 

  14. Thomalla JV, Thompson ST, Rowland RG, et al. Infectious complications of penile prosthetic implants. J Urol 1987; 138: 65–67.

    PubMed  CAS  Google Scholar 

  15. Carson CC. Infections in genitourinary prostheses. Urol Clin North Am 1989; 16: 139–147.

    PubMed  CAS  Google Scholar 

  16. Fishman IJ, Scott FB, Selim AM. Rescue procedure. An alternative to complete removal for treatment of infected penile prostheses (Abstract). J Urol 1987; 137: 202A (Abstr 396).

    Google Scholar 

  17. Furlow WL, Goldwasser B. Salvage of the eroded inflatable penile prosthesis: a new concept. J Urol 1987; 138: 312–314.

    PubMed  CAS  Google Scholar 

  18. Teloken C, Souto JC, DaRos C et al. Prosthetic penile infection: rescue procedure with rifamycin. J Urol 1992; 148: 1905–1906.

    PubMed  CAS  Google Scholar 

  19. Moatman TJ, Montague DK. Intracorporeal drainage after removal of infected penile prostheses. Urology 1984; 23: 184–185.

    Article  Google Scholar 

  20. McClellan DS, Masih BK. Gangrene of the penis as a complication of penile prosthesis. J Urol 1985; 133: 862–863.

    PubMed  CAS  Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1997 Springer Science+Business Media New York

About this chapter

Cite this chapter

Mulcahy, J.J. (1997). The Complex Penile Prosthesis. In: Hellstrom, W.J.G. (eds) Male Infertility and Sexual Dysfunction. Springer, New York, NY. https://doi.org/10.1007/978-1-4612-1848-7_41

Download citation

  • DOI: https://doi.org/10.1007/978-1-4612-1848-7_41

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-1-4612-7310-3

  • Online ISBN: 978-1-4612-1848-7

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics