Abstract
Penile prosthesis placement has remained a predictable and reliable treatment for erectile dysfunction for over two decades. Despite advances in prosthetic design and the use of more durable materials, mechanical problems with these devices may occur. In addition, weakness in the wall of the erectile bodies, the deposition of scar tissue in the penis, problems with blood supply, and the entrance of bacteria into the wound at the time of implant surgery have contributed to a suboptimal result in certain patients. Fortunately, as experience has been gained, the incidence of complications has decreased and the management of problems has become more timely and more gratifying.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Fallon B, Ghanem H. Sexual performance and satisfaction with penile prostheses in impotence of various etiologies. Int J Impotence Res 1990; 2: 35–42.
Mulcahy JJ. A technique for maintaining penile prosthesis position to prevent proximal migration. J Urol 1987; 17: 294–296.
Montague DK, Lakin MM. Early experience with the controlled girth and length expanding cylinder of the American Medical Systems Ultrex penile prosthesis. J Urol 1992; 148: 1444–1446.
Wilson SK, Delk JR. The “S” deformity: a complication of AMS 700 ultrex penile prosthesis. Int J Impotence Res 1994; 6 (suppl 1): D168.
Wilson SK, Delk JR. A new treatment for Peyronie’s disease: modeling the penis over an inflatable penile prosthesis. J Urol 1994; 152: 1121–1123.
Mulcahy JJ, Rowland RG. Tunica wedge excision to correct penile curvature associated with the inflatable penile prosthesis. J Urol 1987; 138: 63–64.
Nesbit RM. Congenital curvature of the phallus: report of three cases with description of corrective operation. J Urol 1965; 93: 230–232.
Steidl CS, Mulcahy JJ. Erosion of penile prosthesis: a complication of ureteral catheterization. J Urol 1989; 142: 736–739.
Fitch WP, Roddy T. Erosion of inflatable penile prosthesis reservoir into bladder. J Urol 1986; 136: 1080.
Ball TP. Surgical repair of penile “SST” deformity. Urology 1980; 15: 603–604.
Parulkar BG, Lamb B, Vickers MA Jr. The detection of leakage in inflatable urinary devices (Abstract). J Urol 1994; 153: 358A (Abstr 519).
Kabalin JN, Kessler R. Infectious complications of penile prosthesis surgery. J Urol 1988; 139: 953–955.
Montague DK. Periprosthetic infections. J Urol 1987; 138: 68–69.
Thomalla JV, Thompson ST, Rowland RG, et al. Infectious complications of penile prosthetic implants. J Urol 1987; 138: 65–67.
Carson CC. Infections in genitourinary prostheses. Urol Clin North Am 1989; 16: 139–147.
Fishman IJ, Scott FB, Selim AM. Rescue procedure. An alternative to complete removal for treatment of infected penile prostheses (Abstract). J Urol 1987; 137: 202A (Abstr 396).
Furlow WL, Goldwasser B. Salvage of the eroded inflatable penile prosthesis: a new concept. J Urol 1987; 138: 312–314.
Teloken C, Souto JC, DaRos C et al. Prosthetic penile infection: rescue procedure with rifamycin. J Urol 1992; 148: 1905–1906.
Moatman TJ, Montague DK. Intracorporeal drainage after removal of infected penile prostheses. Urology 1984; 23: 184–185.
McClellan DS, Masih BK. Gangrene of the penis as a complication of penile prosthesis. J Urol 1985; 133: 862–863.
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1997 Springer Science+Business Media New York
About this chapter
Cite this chapter
Mulcahy, J.J. (1997). The Complex Penile Prosthesis. In: Hellstrom, W.J.G. (eds) Male Infertility and Sexual Dysfunction. Springer, New York, NY. https://doi.org/10.1007/978-1-4612-1848-7_41
Download citation
DOI: https://doi.org/10.1007/978-1-4612-1848-7_41
Publisher Name: Springer, New York, NY
Print ISBN: 978-1-4612-7310-3
Online ISBN: 978-1-4612-1848-7
eBook Packages: Springer Book Archive