Abstract

The majority of the present knowledge of the three-dimensional kinematic behavior of skeletal joints has been acquired in studies employing cadaveric models using invasive procedures. In the wrist, the small size and complex motion of the carpal bones present a difficult challenge for an invasive kinematic analysis or external marker system. This paper describes an approach to quantify the three-dimensional kinematics of the wrist and carpal bones in vivo, using non-invasive computed tomographic (CT) imaging. The applications of this method include quantification of normal wrist motion, analysis of pathomechanics, and evaluation of surgical intervention. The approach is also applicable to other joints and imaging modalities.

References

  1. 1.
    Banks SA, Markovitch GD, Hodge WA. In vivo kinematics of the cruciate retaining and substituting knee replacements. J Arthroplasty, 12(3): 297–304, 1997.CrossRefPubMedGoogle Scholar
  2. 2.
    Belsole RJ, Hilbelink DR, Llewellyn JA, Dale M, Ogden JA. Carpal orientation from computed reference axes. J Hand Surg, 16A(1): 82–90, 1991.CrossRefGoogle Scholar
  3. 3.
    Crisco JJ, McGovern RD. Efficient calculation of mass moments of inertia for segmented homogeneous 3D objects. J Biomech, 31(1):97–101, 1998.CrossRefPubMedGoogle Scholar
  4. 4.
    Crisco JJ, McGovern RD, Wolfe SW. Three dimensional kinematics of carpal bones: an in vitro error analysis. Am Soc Biomech Conference, Clemson, SC, Sept 22–24, 1997.Google Scholar
  5. 5.
    de Lange A, Kauer JMG, Huiskes R. Kinematic Behavior of the Human Wrist Joint: A Roentgen-Stereophotogrammetric Analysis. J Orthop Res, 3:56–64, 1985.CrossRefPubMedGoogle Scholar
  6. 6.
    Horii E, Garcia-Elias M, An KN, Linschcid RL, Bishop AT, Cooney WP, Chao EYS. A kinematic study of lunotriquetral dissociations. J Hand Surgery, 16(2):355–362, 1991.CrossRefGoogle Scholar
  7. 7.
    Lafortunc MA, Cavanagh PR, Sommer HJ, Kalenak A. Three-dimensional kinematics of the human knee during walking. J Biomech, 25(4):347–358, 1992.CrossRefGoogle Scholar
  8. 8.
    Patterson RM, Elder KW, Viegas SF, Buford WL. Carpal bone anatomy measured by computer analysis of three-dimensional reconstructions of computed tomography images. J Hand Surgery, 20(6):923–929, 1995.CrossRefGoogle Scholar
  9. 9.
    Pelizzari CA, Chen GT, Spelbring DR, Weichselbaum RR, Chen CT. Accurate three-dimensional registration of CT, PET. and/or MR images of the brain. J Comput Assist Tomogr, 13(1):20–26, 1989.CrossRefPubMedGoogle Scholar
  10. 10.
    Robb RA.Three-dimensional Biomedical Imaging: Principles and Practice. VCH, N.Y., N.Y., 1995.Google Scholar
  11. 11.
    Viegas SF, Hillman GR, Elder K, Stoner D, Patterson RM. Measurement of carpal bone geometry by computer analysis of three-dimensional CT images. J Hand Surg, 18A(2):341–349, 1993.CrossRefGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 1998

Authors and Affiliations

  • Joseph J. Crisco
    • 1
    • 2
    Email author
  • Robert D. McGovern
    • 1
  • Scott W. Wolfe
    • 3
  1. 1.Department of OrthopaedicsRhode Island HospitalProvidence
  2. 2.Division of EngineeringBrown UniversityProvidence
  3. 3.Department of OrthopaedicsYale University School of MedicineNew Haven

Personalised recommendations