This paper describes the development and preliminary testing of an image-guided system for the placement of iliosacral screws to stabilize pelvic ring fractures percutaneously, with the aim of decreasing the incidence of surgical complications and increasing the accuracy of screw placement. Pre-operative planning of screw trajectories is performed on a 3D model of the pelvis constructed from CT scans. During surgery, a 6D optical localizer is used to track the positions and orientations of an ultrasound probe, a surgical drill and a reference frame fixed to the posterior iliac crest. Registration of the pre-operative model with curves segmented from the ultrasound scans is performed using a surface-based algorithm. The drill tip and axis are displayed relative to the desired screw trajectories in real time. The accuracy of the system has been verified in four cadaver specimens by comparing actual screw trajectories to the desired trajectories and by measuring the distance from each screw to important anatomical landmarks on post-operative CT scans. All screws were considered to be in correct position.

Keywords

Pelvic Fracture Drilling Process Iliosacral Screw Pelvic Ring Fracture Posterior Iliac Crest 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

References

  1. 1.
    Waddel J.P. Pennal G.F., Tile M. and Garside H. Pelvic disruption: Assessment and classification. Clinical Orthopaedic, (151):12–21, 1980.Google Scholar
  2. 2.
    E. Letournel. Pelvic fractures. Rev. Chir. Orthop., (10):145–148, 1978.Google Scholar
  3. 3.
    JM. Matta and T. Saucedo. Internal fixation of pelvic fracture. Clin. Orthop., (242):83–97, 1989.Google Scholar
  4. 4.
    M. Tile and GF. Pennal. Pelvic disruption: Principe of management. Clin. Orthop., (151):56–64, 1980.Google Scholar
  5. 5.
    Freese J. Templeman D., Schmidt A. and Weisman I. Proximity of iliosacral screws to neurovascular structures after internal fixation. Clinical Orthopaedic, (329):194–198, 1996.Google Scholar
  6. 6.
    Coombs R.J. Jackson W.T. Ebraheim N.A., Russin J.J. and Holiday B. Percutaneous computer-tomography stabilization of pelvic fractures. Prelimnary report. J. Orthop. Trauma., (1):197–204, 1987.Google Scholar
  7. 7.
    M.L. Routt and P.T. Simonian. Closed reduction and percutaneous skeletal fixation of sacral fractures. Clinical Orthopaedic, (329): 121–128, 1996.Google Scholar
  8. 8.
    C. Barbe, J. Troccaz, B. Mazier, and S. Lavallee. Using 2.5D echography in computer assisted spine surgery. In IEEE Engineering in Medicine and Biology Society Proceedings, pages 160–161. IEEE, 1993.Google Scholar
  9. 9.
    R. Mosges and S. Lavallee. Multimodal information for computer-integrated surgery. In R. Taylor, S. Lavallee, G. Burdea, and R. Mosges, editors, Computer-integrated surgery: technology and clinical applications, pages 5–20. MIT Press, Cambridge, MA, 1996.Google Scholar
  10. 10.
    A.L. Jacob. Computer assistance in pelvic and acetabular fractures. In L. Nolte, editor, CAOS’96 (Computer Assisted Orthopaedic Surgery), Bern (CH), 1996. Muller Institute.Google Scholar
  11. 11.
    R. Hu, N. Glossop, D. Steven, and J. Randle. Accuracy of image guided placement of iliosacral lag screws. In J. Troccaz and al., editors, CVRMed-MRCAS’97 Proc, LNCS Series 1205, pages 593–596. Springer, 1997.Google Scholar
  12. 12.
    S. Lavallee, P. Sautot, J. Troccaz, P. Cinquin, and P. Merloz. Computer Assisted Spine Surgery: a technique for accurate transpedicular screw fixation using CT data and a 3D optical localizer. Journal of Image Guided Surgery, 1(1):65–73, 1995.CrossRefPubMedGoogle Scholar
  13. 13.
    S. Lavallee, R. Szeliski, and L. Brunie. Anatomy-based registration of 3-D medical images, range images, X-ray projections, 3-D models using Octree-Splines. In R. Taylor, S. Lavallee, G. Burdea, and R. Mosges, editors, Computer Integrated Surgery, pages 115–143. MIT Press, Cambridge, MA, 1996.Google Scholar
  14. 14.
    P. Merloz, J. Tonetti, A. Eid, C. Faure, S. Lavallee, J. Troccaz, P. Sautot, A. Hamadeh, and P. Cinquin. Computer Assisted Spine Surgery. Clinical Orthopaedics and related Research, (337):86–96, 1997.CrossRefGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 1998

Authors and Affiliations

  • Lionel Carrat
    • 1
  • Jerome Tonetti
    • 2
  • Stephane Lavallee
    • 1
  • Philippe Merloz
    • 3
  • Laurence Pittet
    • 4
  • Jean-Paul Chirossel
    • 2
  1. 1.TIMC Laboratory, Faculté de MédecineI.A.B.La TroncheFrance
  2. 2.Anatomy Laboratory, Pr ChirosselUniversity Joseph FourierGrenoble
  3. 3.Orthopaedic DepartmentCHU A. MichallonGrenoble
  4. 4.Radiology DepartmentCHU A. MichallonGrenoble

Personalised recommendations