Advertisement

Electromagnetic detectors

  • Glen R. Lambertson
Conference paper
Part of the Lecture Notes in Physics book series (LNP, volume 343)

Keywords

Beam Current Current Transformer Longitudinal Electric Field Beam Tube Stochastic Cool 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    T. Linnecar, “The High Frequency Longitudinal and Transverse Pickups Used in the SPS,” CERN-SPS/ARF/78-71 (August 1978).Google Scholar
  2. 2.
    S. van der Meer, “Stochastic Cooling in the CERN Antiproton Accumulator,” IEEE Trans. Nucl. Sci. NS-28, 1994 (June 1981).Google Scholar
  3. 3.
    K. Unser, “A Toroidal DC Beam Current Transformer with High Resolution,” IEEE Trans. Nucl. Sci. NS-28, 2344 (June 1981).Google Scholar
  4. 4.
    G.C. Schneider, “A 1.5 GHz Wide-Band Beam-Positron and Intensity Monitor for the Electron-Positron Accumulator (EPA),” Proc. of the 1987 IEEE Particle Accelerator Conference, Vol. 1, 664 (March 1987).Google Scholar
  5. 5.
    R.E. Colin, Foundations for Microwave Engineering, pp. 56–59, (McGraw Hill, 1966).Google Scholar
  6. 6.
    W.K.H. Panofsky and W.A. Wenzel, Rev. Sci. Instr. 27, 967 (November 1956). G.R. Lambertson, “Dynamic Devices-Pickups and Kickers,” Physics of Particle Accelerators, Eds. M. Month and M. Dienes, AIP 153, Vol. 1, p. 1413 (1987).Google Scholar
  7. 7.
    J.C. Slater, Microwave Electronics, Van Nostrand, Princeton, NJ (1950).Google Scholar
  8. 8.
    E.L. Ginzton, Microwave Measurements, McGraw Hill, New York, NY (1957), pp. 445–449.Google Scholar
  9. 9.
    D.A. Goldberg and G.R. Lambertson, “A High-Frequency Schottky Detector for Use in the Tevatron,” Proc. of the 1987 IEEE Particle Accelerator Conference, 1, 547 (March 1987), Lawrence Berkeley Laboratory Report LBL-22273.Google Scholar
  10. 10.
    Q. Kerns et al, “Tuned Beam Position Detector for the Fermilab Switchgard,” Proc. of the 1987 IEEE Particle Accelerator Conference, 1, 661 (March 1987).Google Scholar
  11. 11.
    J. Durand et al., “New Electrostatic Pickups for the PS,” presented at European Particle Accelerator Conf., Rome (June 1988), CERN/PS 88-42 (PA) (June 1988).Google Scholar
  12. 12.
    D. Goldberg, G. Lambertson, F. Voelker, and L. Shalz, “Measurement of Frequency Response of LBL Stochastic Cooling Arrays for TEV-I Storage Rings,” IEEE Trans. Nucl. Sci. NS-32, 2168 (October 1985), Lawrence Berkely Laboratory Report LBL-19564.Google Scholar
  13. 13.
    B. Autin et al., “Applications of Microwaves to Antiproton Control,” Alta Frequenza, Vol. 56, N10, 381 (December 1987).Google Scholar
  14. 14.
    G. Lambertson, “The Helix as a Beam Electrode,” Lawrence Berkeley Laboratory, Internal Report BECON-60 (August 1985).Google Scholar
  15. 15.
    H. Yonehara et al., INS-NUMA-49 (1983).Google Scholar
  16. 16.
    G. Lambertson et al., “Experiments on Stochastic Cooling of 200 MeV Protons,” IEEE Trans. Nucl. Sci. NS-28, 2471 (June 1981), Lawrence Berkeley Laboratory Report LBL-11753.Google Scholar
  17. 17.
    G. Lambertson, K.J. Kim, and F. Voelker, “The Slotted Coax as a Beam Electrode,” IEEE Trans. Nucl. Sci. NS-30, 2158 (August 1983), Lawrence Berkeley Laboratory Report LBL-15136.Google Scholar
  18. 18.
    J. Bosser et al., “Design and Performance of the AAC Stack Core Cooling System,” Presented at European Particle Accelerator Conference, Rome (June 1988), CERN/PS/88-25 (AR).Google Scholar
  19. 19.
    D. Boussard and G. DiMassa, “High Frequency Slow Wave Pickups,” CERN-SPS/86-4(ARF), (February 1986).Google Scholar

Copyright information

© Springer-Verlag 1989

Authors and Affiliations

  • Glen R. Lambertson
    • 1
  1. 1.Accelerator and Fusion Research DivisionLawrence Berkeley LaboratoryBerkeleyUSA

Personalised recommendations