Abstract
A structural design of airborne electronic equipment with a total heat consumption of 1205 W and a maximum heat consumption of 105 W for a LRM, which includes 26 functional modules (LRMs) and complicated interconnection among internal LRMs, is introduced. The overall structure and characteristics of the electronic equipment and the design scheme of the liquid cooling system are described in detail. The design scheme has been validated in a certain project to meet the requirements of GJB150A-2009. It has been proved that the equipment has compact structure, reasonable heat dissipation and better mechanical properties. A structural design for similar equipment is provided.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Ye, F.: Thermal design of airborne liquid cooler frame based on ASAC standard module, 30(5), 7–12 (2014)
Wu, W.: Design of multi-layer liquid cooling frame based on hose, 30(1), 127–129 (2017)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Science Press
About this paper
Cite this paper
Wang, J. (2020). Structural Design of a High Heat Consumption at Airborne Electronic Equipment. In: Duan, B., Umeda, K., Hwang, W. (eds) Proceedings of the Seventh Asia International Symposium on Mechatronics. Lecture Notes in Electrical Engineering, vol 588. Springer, Singapore. https://doi.org/10.1007/978-981-32-9437-0_13
Download citation
DOI: https://doi.org/10.1007/978-981-32-9437-0_13
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-32-9436-3
Online ISBN: 978-981-32-9437-0
eBook Packages: Intelligent Technologies and RoboticsIntelligent Technologies and Robotics (R0)