Abstract

This chapter reviews different converter topologies and output filter configurations used in STATCOM applications. The output voltage and harmonic control of a STATCOM is obtained by individual control of each switch in the STATCOM. Several converter topologies can be considered for STATCOMs. The multi-pulse converters are developed using the most widely known 6-pulse configurations. The variations of multi-pulse converters such as 12-pulse, 24-pulse and 48-pulse that are built by combining 6-pulse converters via phase-shifting isolation transformers are introduced in terms of control methods and structures in this chapter. On the other hand, the multilevel converters are considered to be used in recent STATCOM topologies as an alternative to the multi-pulse configurations, owing to their multi MVA switching capability that is inherited from series or parallel connection of converter cells. The diode clamped, flying capacitor, and cascaded H-bridge configurations of multilevel converters, that are the most widely known topologies, are comprehensively introduced in this chapter. The multilevel converter topologies provide several advantages such as harmonic elimination, lower electromagnetic interference, better output waveforms, and increased power factor correction (PFC) capabilities together. Furthermore, each switch can be controlled individually to robustly tackle the unbalanced load operations even in higher switching frequencies relatively to the multi-pulse configuration. The related subsections propose control and operation properties of converters besides introducing the main topological issues. The filtering requirements of STATCOM are particularly considered in this chapter where the passive and active filters are introduced in detail. The passive filters designed with reactive components such as individual L and C or their combinations as LC or LCL are surveyed according to design and analytical criteria. Besides, active power filters (APFs) that provide several feedback control methods increasing the efficiency and controllability are discussed in the following part. The control methods of STATCOM converters are introduced in a separate section where the recent control approaches and analytical calculations required are presented in detail. The block diagrams of the industrial STATCOM applications are also discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Watanabe EH, Aredes M, Barbosa PG, de Araújo Lima FK, da Silva Dias RF, Santos G Jr (2011) 32—Flexible AC transmission systems. In: Rashid MH (ed) Power electronics handbook, 3rd edn. Butterworth-Heinemann, Boston, pp 851–877

    Google Scholar 

  2. Acha E, Agelidis V, Anaya O, Miller TJE (2002) Power electronic control in electrical systems. Newnes Power Engineering Series. ISBN-13: 978-0750651264

    Google Scholar 

  3. Mathur RM, Varma RK (2002) Thyristor-based facts controllers for electrical transmission systems. Wiley-IEEE Press, Hoboken, ISBN: 978-0-471-20643-9

    Google Scholar 

  4. Kasikci I (2004) Analysis and design of low-voltage power systems: an engineer’s field guide. Wiley, ISBN: 978-3-527-30483-7

    Google Scholar 

  5. Luo FL, Ye H, Rashid M (2005) Digital power electronics and applications. Elsevier, USA, ISBN: 0-1208-8757-6

    Google Scholar 

  6. Barik SR, Nayak B, Dash S (2014) A comparative analysis of three level VSC based multi-pulse STATCOM. Int J Eng Technol (IJET) 6(3):1550–1563

    Google Scholar 

  7. Kouadri Benatman, Tahir Yamina (2008) Power flow and transient stability modelling of a 12-pulse STATCOM. J Cybern Inf 7:9–25

    Google Scholar 

  8. Singh B, Srinivas KV (2009) Three-level 12-pulse STATCOM with constant DC link voltage. In: Annual IEEE India conference (INDICON), 18–20 Dec 2009, pp 1–4

    Google Scholar 

  9. Anadol MA, Aydin M, Yalcinoz T (2013) A real-time extraction of active and reactive current using microcontrollers for a multipulse STATCOM. Turk J Electr Eng Comput Sci 21(4):1044–1060

    Google Scholar 

  10. Chandrasekhar S, Brahmmam J, Srinu M (2013) Mitigation of voltage flicker and reduction in THD by using STATCOM. Int J Electr Comput Eng (IJECE) 3(1):102–108

    Google Scholar 

  11. Agiwara MH, Akagi H (2005) An approach to regulating the DC-link voltage of a voltage-source BTB system during power line faults. IEEE Trans Ind Appl 41(5):1263–1271

    Article  Google Scholar 

  12. Hagiwara M, Fujita H, Akagi H (2003) Performance of a self-commutated BTB HVDC link system under a single-line-to-ground fault condition. IEEE Trans Power Electron 18(1):278–285

    Article  Google Scholar 

  13. Voraphonpiput, N, Chatratana, S (2004) Analysis of quasi 24-pulse STATCOM operation and control using ATP-EMTP. In: IEEE region 10 conference TENCON 2004, 21–24 Nov 2004, vol C, pp 359–362

    Google Scholar 

  14. Singh B, Saha R (2006) A new 24-pulse STATCOM for voltage regulation. In: International conference on power electronics, drives and energy systems, 12–15 Dec 2006, pp 1–5

    Google Scholar 

  15. Srinivas KV, Singh B (2010) Three-level 24-pulse STATCOM with pulse width control at fundamental frequency switching. In: IEEE industry applications society annual meeting (IAS), 3–7 Oct 2010, pp 1–6

    Google Scholar 

  16. Khorrami Navid (2012) Simulation and modeling of 24-pulse STATCOM in EMTDC/PSCAD program in order to regulate voltage and dynamic stability improvement. Res J Appl Sci Eng Technol 4(3):152–158

    Google Scholar 

  17. Geethalakshmi B, Dananjayan P (2009) A combined multipulse-multilevel inverter based STATCOM for improving the voltage profile and transient stability of power system. Int J Power Electron 1(3):267–285

    Article  Google Scholar 

  18. Padmaja SM, Tulasiram Das G (2011) A novel controller based 48-pulse STATCOM for reactive power compensation and voltage stabilization in high voltage applications. ACEEE Int J Electr Power Eng 2(1):43–49

    Google Scholar 

  19. Molina Marcelo G, Mercado Pedro E (2013) Primary frequency control of multi-machine power systems with STATCOM-SMES: a case study. Electr Power Energy Syst 44:388–402

    Article  Google Scholar 

  20. El-Moursi MS, Sharaf AM (2006) Novel reactive power controllers for the STATCOM and SSSC. Electr Power Syst Res 76:228–241

    Article  Google Scholar 

  21. Colak Ilhami, Kabalci Ersan, Bayindir Ramazan (2011) Review of multilevel voltage source inverter topologies and control schemes. Energy Convers Manage 52(2):1114–1128

    Article  Google Scholar 

  22. Colak Ilhami, Kabalci Ersan (2011) Practical implementation of a digital signal processor controlled multilevel inverter with low total harmonic distortion for motor drive applications. J Power Sources 196(18):7585–7593

    Article  Google Scholar 

  23. Gultekin B, Gerçek CO, Atalik T, Deniz M, Biçer N, Ermis M, Kose KN, Ermis C, Koç E, Çadirci I, Açik A, Akkaya Y, Toygar H, Bideci S (2012) Design and implementation of a 154-kV ± 50-Mvar transmission STATCOM based on 21-level cascaded multilevel converter. IEEE Trans Ind Appl 48(3):1030–1045

    Article  Google Scholar 

  24. Shaha NM, Soodb VK, Ramachandran V (2009) Modeling, control and simulation of a chain link STATCOM in EMTP-RV. Electr Power Sys Res 79:474–483

    Article  Google Scholar 

  25. Muñoz Javier A, Espinoza José R, Baier Carlos R, Morán Luis A, Guzmán Johan I, Cárdenas Víctor M (2014) Decoupled and modular harmonic compensation for multilevel STATCOMs. IEEE Trans Ind Electron 61(6):2743–2753

    Article  Google Scholar 

  26. Meynard TA, Foch H (1992) Multi-level conversion: high voltage choppers and voltage-source inverters. In: 23rd Annual IEEE power electronics specialists conference, vol 1, pp 397–403

    Google Scholar 

  27. Soto Diego, Green Tim C (2012) A comparison of high-power converter topologies for the implementation of FACTS controllers. IEEE Trans Ind Electron 49(5):1072–1080

    Article  Google Scholar 

  28. Gultekin Burhan, Ermis Muammer (2013) Cascaded multilevel converter-based transmission STATCOM: system design methodology and development of a 12 kV ± 12 MVAr power stage. IEEE Trans Power Electron 28(11):4930–4950

    Article  Google Scholar 

  29. Zhao G, Liu J, Han M (2011) Design of input filters considering the stability of STATCOM systems. J Power Electr 11(6):904–913

    Article  Google Scholar 

  30. Wang Bingsen, Cathey Jimmie J (2003) DSP-controlled, space-vector PWM, current source converter for STATCOM application. Electr Power Syst Res 67:123–131

    Article  Google Scholar 

  31. Xia Zhenglong, Shi Liping, Yang Xiaodong (2014) Parameters design and control strategy of cascade STATCOM based on LCL filter. Int J Control Autom 7(1):307–320

    Article  Google Scholar 

  32. Okou FA, Dupuis D, Akhrif O, Tarbouchi M (2009) A robust nonlinear controller for a StatCom based on a 3-phase neutral point clamped converter. In: 35th Annual conference of IEEE industrial electronics, pp 3623–3630

    Google Scholar 

  33. Wang C, Yin X, Wen M, Jian L, Xiong Q, Zhang B (2010) Structure and parameters design of output LC filter in D-STATCOM. In: International conference on power system technology (POWERCON), pp 1–6

    Google Scholar 

  34. Lauttamus P, Tuusa H (2011) Model-based cascade control of three-level STATCOM with a tuned LCL-filter. In: Twenty-sixth annual IEEE applied power electronics conference and exposition (APEC), 6–11 Mar 2011, pp 1569–1575

    Google Scholar 

  35. Escobar G, Stankovic AM, Mattavelli P(2000) Reactive power, imbalance and harmonics compensation using D-STATCOM with a dissipativity-based controller. In: Proceedings of the 39th IEEE conference on decision and control, vol 4, pp 3051–3055

    Google Scholar 

  36. Ping T, Xianggen Y, Zhe Z (2011) Topology analysis of the output filter in D-STATCOM and its parameters multi-objective optimal design. In: International conference on advanced power system automation and protection, 16–20 Oct 2011, vol 2, pp 998–1002

    Google Scholar 

  37. He Chao, Xie Xin, Yan Hui, Xie Chuan, Chen Guozhu (2011) A novel grid-connected converter with active power filtering function. Energy Procedia 12:348–354

    Article  Google Scholar 

  38. Tavakoli Bina M, Eskandari MD, Panahlou M (2005) Design and installation of a ± 250 kVAr D-STATCOM for a distribution substation. Electr Power Syst Res 73(3):383–391

    Article  Google Scholar 

  39. Nakamura S, Kojima H, Matsui K, Mori H, Ueda F (2005) STATCOM circuit having active filter function for lower order harmonics. In: The international conference on electrical engineering, vol 1, pp 1–6

    Google Scholar 

  40. Morán L, Dixon J, Espinoza J, Wallace R (1999) Using active power filters to improve power quality. In: 5th Brasilian power electronics conference, 19–23 Sept 1999, pp 501–511

    Google Scholar 

  41. Afonso JL, Aredes M, Watanabe E, Martins JS (2000) Shunt active filter for power quality improvement. In: International conference UIE 2000—electricity for a sustainable urban development, Lisboa, Portugal, 1–4 Nov 2000, pp 683–691

    Google Scholar 

  42. Basu TS, Bhattacharya A, Chakraborty C (2010) Shunt active power filter/STATCOM topology for medium/high power applications: parallel inverters operating at different switching frequencies. In: 36th annual conference on IEEE industrial electronics society, 7–10 Nov 2010, pp 2669–2674

    Google Scholar 

  43. Kanaan HY, Hayek A, Al-Haddad K (2007) Averaged-model-based nonlinear control of a PWM three-phase four-leg shunt active power filter. In: Canadian conference on electrical and computer engineering, 22–26 Apr 2007, pp 1002–1005

    Google Scholar 

  44. Kalyankumar D, Kirubakaran V (2010) D-STATCOM based voltage regulation and harmonic damping. Int J Comput Appl 7(4):39–43

    Google Scholar 

  45. Sanz-Bobi MA (ed) (2014) Use, operation and maintenance of renewable energy systems, green energy and technology. Springer International Publishing, Switzerland. doi:10.1007/978-3-319-03224-5_7

  46. Routray SK, Nayak N, Rout PK (2010) A robust fuzzy sliding mode control design for current source inverter based STATCOM application. Procedia Technol 4:342–349

    Article  Google Scholar 

  47. Fukuda S, Imamura R (2005) Application of a sinusoidal internal model to current control of three-phase utility-interface converters. IEEE Trans Ind Electron 52(2):420–426

    Article  Google Scholar 

  48. Filizadeh S, Gole AM (2005) Harmonic performance analysis of an OPWM-controlled STATCOM in network applications. IEEE Trans Power Delivery 20(2):1001–1008

    Article  Google Scholar 

  49. Cetin A, Ermis M (2009) VSC-based D-STATCOM with selective harmonic elimination. IEEE Trans Ind Appl 45(3):1000–1015

    Article  Google Scholar 

  50. Lin W (2006) A new approach to the harmonic analysis of SPWM waves. In: Proceedings of the 2006 IEEE international conference on mechatronics and automation, 25–28 June 2006, pp 390–394

    Google Scholar 

  51. Ghuo Pan Z, Peng FZ (2007) A novel SPWM method with voltage balancing capability for multilevel rectifier/inverter systems. In: Twenty second annual IEEE applied power electronics conference, 25 Feb–1 Mar 2007, pp 1109–1115

    Google Scholar 

  52. Hua CC, Wu CW, Chuang CW (2007) Fully digital control of 27-level cascade inverter with variable DC voltage sources. In: 2nd IEEE conference on industrial electronics and applications, 23–25 May 2007, pp 2441–2448

    Google Scholar 

  53. Colak Ilhami, Kabalci Ersan (2013) Developing a novel sinusoidal pulse width modulation (SPWM) technique to eliminate side band harmonics. Int J Electr Power Energy Syst 44(1):861–871

    Article  Google Scholar 

  54. Kabalci E (2014) Power electronics and drives used in automotive applications. In: Bizon N, Dascalescu L, Tabatabaei NM (eds) Autonomous vehicles: intelligent transport systems and smart technologies. ISBN: 978-1-63321-324-1, 3rd Quarter

    Google Scholar 

  55. Sao CK, Lehn PW, Iravani MR, Martinez JA (2002) A benchmark system for digital time-domain simulation of a pulse-width-modulated D-STATCOM. IEEE Trans Power Delivery 17(4):1113–1120

    Article  Google Scholar 

  56. Patel HS, Hoft RG (1973) Generalized harmonic elimination and voltage control in thyristor converters: part I—harmonic elimination. IEEE Trans Ind Appl 9:310–317

    Article  Google Scholar 

  57. Mohapatra M, Babu BC (2010) Fixed and sinusoidal-band hysteresis current controller for PWM voltage source inverter with LC filter. In: Students’ technology symposium (TechSym). 3–4 Apr 2010, IEEE, pp 88–93

    Google Scholar 

  58. Venkata Ranganadh B, Mallikarjuna Prasad A, Sreedhar M (2013) Modelling and simulation of a hysteresis band pulse width modulated current controller applied to a three phase voltage source inverter by using matlab. Int J Adv Res Electr Electron Instrum Eng 2(9):4378–4387

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ersan Kabalci .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer Science+Business Media Singapore

About this chapter

Cite this chapter

Kabalci, E. (2015). Converter and Output Filter Topologies for STATCOMs. In: Shahnia, F., Rajakaruna, S., Ghosh, A. (eds) Static Compensators (STATCOMs) in Power Systems. Power Systems. Springer, Singapore. https://doi.org/10.1007/978-981-287-281-4_1

Download citation

  • DOI: https://doi.org/10.1007/978-981-287-281-4_1

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-287-280-7

  • Online ISBN: 978-981-287-281-4

  • eBook Packages: EnergyEnergy (R0)

Publish with us

Policies and ethics