Skip to main content

A Comparative Study of Grid Synchronization Techniques SRF-PLL and DSRF-PLL Under Unbalanced Grid Voltage Condition

  • Conference paper
  • First Online:
Advances in Electric Power and Energy Infrastructure

Abstract

This paper presents a comparative study of two grid synchronization techniques, synchronous reference frame phase-locked loop (SRF-PLL) and double synchronous reference frame phase-locked loop (DSRF-PLL) that could be used in grid integration of distributed generation systems. As PLL is playing a vital role in the operation of grid-connected power electronic converters, it is very much important to study their behavior in grid voltage fluctuating condition. It is shown that SRF-PLL gives suitable response when the grid voltage is balanced, but during fluctuating condition of voltage its performance gets deteriorated. But DSRF-PLL is able to track grid voltage phase properly in both conditions as it is having two components separated and decoupled from each other using decoupling network. Performance comparison is verified by MATLAB simulation, and the results are presented.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Timbus FBA, Liserre M, Teodorescu R (2005) Synchronization methods for three-phase distributed power generation systems. An overview and evaluation. In: Proceedings of the IEEE 36th power electronics specialists conference, pp 2474–2481

    Google Scholar 

  2. Yan Z, Milanovic JV (2010) Global voltage sag mitigation with FACTS-based devices. IEEE Trans Power Deliv 25:2842–2850

    Google Scholar 

  3. Ding G et al (2008) New technologies of voltage source converter (VSC) for HVDC transmission system based on VSC. In: Power and energy society general meeting-conversion and delivery of electrical energy in the 21st century, IEEE

    Google Scholar 

  4. Golestan S, Monfared M, Freijedo FD (2013) Design-oriented study of advanced synchronous reference frame phase-locked loops. IEEE Trans Power Electron 28(2)

    Article  Google Scholar 

  5. Rodríguez P, Pou J, Bergas J et al (2007) Decoupled double synchronous reference frame PLL for power converters control. IEEE Trans Power Electron 22(2)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Atul Kunpara .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Kunpara, A., Kamat, V.N. (2020). A Comparative Study of Grid Synchronization Techniques SRF-PLL and DSRF-PLL Under Unbalanced Grid Voltage Condition. In: Mehta, A., Rawat, A., Chauhan, P. (eds) Advances in Electric Power and Energy Infrastructure. Lecture Notes in Electrical Engineering, vol 608. Springer, Singapore. https://doi.org/10.1007/978-981-15-0206-4_15

Download citation

  • DOI: https://doi.org/10.1007/978-981-15-0206-4_15

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-15-0205-7

  • Online ISBN: 978-981-15-0206-4

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics