Skip to main content

The State Detection Scheme of the Hard Plate in Substation Based on Hall Sensing Effect

  • Conference paper
  • First Online:
Proceedings of PURPLE MOUNTAIN FORUM 2019-International Forum on Smart Grid Protection and Control

Part of the book series: Lecture Notes in Electrical Engineering ((LNEE,volume 585))

  • 899 Accesses

Abstract

The hardware platen on relay protective panels is the functional demarcation point and the blind spot of condition monitoring between protection device and the control circuit of primary equipments. Realizing the condition monitoring of the hardware platen is the basic need to promote the application of the ubiquitous internet of things in the relay protection specialty. In this paper, a method based on the Hall sensing effect is proposed to detect the state of the hardware platen in the substation, which can realize the automatic detection of the state of the hardware platen without disturbing the outlet control circuit. This paper first proposed the hall element selection scheme for hardware platen state detection, and then developed the configuration scheme of hardware platen state detection device for two kinds of the hardware platen, separated type and line spring type, designed hardware platen state detection integrated circuit, based on that an experimental platform was constructed and the validity and reliability of the proposed scheme was verified.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 149.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 199.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 279.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Hu S, Li L, Zhu X et al (2019) Auxiliary safety measures of protection realy in smart substation based on switching of maintenance states. Autom Electr Power Syst 43(1):242–247

    Google Scholar 

  2. Wu X, Liu C, Li J et al (2008) Remote control technology and its application on relay protection and automatic device strap circuit. Autom Electr Power Syst 32(15):100–103

    Google Scholar 

  3. Yuan H, Qu G, Zhuang W et al (2014) Discussion on condition monitoring contents of secondary equipment in power grid. Autom Electr Power Syst 38(12):100–106

    Google Scholar 

  4. Chen G, Wang D, Qiu Y et al (2017) Challenges and development prospects of relay protection technology. Autom Electr Power Syst 41(16):1–11, 26

    Google Scholar 

  5. Wang J, Liu Z, Zhang C et al (2016) Exploration of new technology for relay protection testing. Autom Electr Power Syst 40(22):1–6

    Google Scholar 

  6. Yao J, Yang S, Gao Z et al (2007) Development trend prospects of power dispatching automation system. Autom Electr Power Syst 31(13):7–11

    Google Scholar 

  7. Zhao Z, Huang H, Zhao C et al (1999) Automatic management system for protective relaying. Autom Electr Power Syst 23(19):55–57

    Google Scholar 

  8. Li J, Tang Y (2014) Condition monitoring and mistake precaution system for power strap based on photoelectric detection. J Chongqing Univ 37(5):29–36

    Google Scholar 

  9. Xia Z, Luo Y, Tu G, Gong C (2005) Image auto-recognition of relay pressed board in on/off states based on visual information. Relay 33(4):40–44

    Google Scholar 

  10. Li Y, Li R, Lu Y et al (2017) Intelligent monitoring system design for circuit breaker operating circuit. Autom Electr Power Syst 37(10):211–217

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hao Xu .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Xu, H. et al. (2020). The State Detection Scheme of the Hard Plate in Substation Based on Hall Sensing Effect. In: Xue, Y., Zheng, Y., Rahman, S. (eds) Proceedings of PURPLE MOUNTAIN FORUM 2019-International Forum on Smart Grid Protection and Control. Lecture Notes in Electrical Engineering, vol 585. Springer, Singapore. https://doi.org/10.1007/978-981-13-9783-7_38

Download citation

  • DOI: https://doi.org/10.1007/978-981-13-9783-7_38

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-13-9782-0

  • Online ISBN: 978-981-13-9783-7

  • eBook Packages: EnergyEnergy (R0)

Publish with us

Policies and ethics