Abstract
This study is to investigate whether the change of the exhaust hood area has an effect on the limiting flow ratio KL in an push–pull ventilation device, especially when the face area of the supply hood is larger than the exhaust hood. This research is based on experiment. Set up a push–pull ventilation device, change the area of the exhaust hood face under the condition of maintaining other factors unchanged. Determine the minimum exhaust volume which completely drains the given air supply without overflow by the tracer method, and the KL could be deduced. The experimental results show that under the above experimental conditions, the change of the exhaust hood area will cause a change on the limiting flow ratio KL, and the larger the gap between the supply and exhaust hood area, the greater the KL value will be. Change the distance between the push and pull hood face, repeat the above experiments, it is verified that the conclusions above are still valid when the distance changes.
Keywords
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
American Conference of Governmental Industrial Hygienists (2010) Industrial ventilation a manual of recommended practice. ACGIH, Cincinnati
Malin BS (1945) Practical pointers on industrial exhaust system. Heat Vent 42:75–82
Tuyosi Y, Katsurou O, Kumasi N (2013) The standard design and maintenance management of local ventilation push- pull ventilator and air cleaner. Japan Ind Safety Health Assoc, Tokyo
Guo P, Fu H, Zhao Y et al (2008) Development and present status of push-pull ventilation technology. J Heating Vent Air Conditioning 38(4):57–61
Tarou H (1986) Factory ventilation. China Architect Building Press, Beijing
Zheng W, Wang Y, Tang Y (2011) Status of researches and applications of push-pull ventilation technology. HV&AC 47(4):1–5
Damin Z, Tsuji K, F Isamu (1987) Simulations of the push-pull flow. Air Conditioning Pap Collect Soc Health Eng 33:33
Tarou H, Howell RH, Makoto S et al (1988) Industrial ventilation and air conditioning. Beijing Industrial University Press, Beijing
Sakurai H, Kanehara K, Fukuhara I et al (2000) Proposal of a simplified equation for push-pull type local ventilation systems. Sci Labour 76(6):261–268
Acknowledgements
This study was supported by the National Key R&D Program of China, Grant No. 2016YFC0801700.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Zhou, S., Yang, B., Zhang, H. (2020). The Influence on the Limit Flow Ratio Caused by the Change of the Area of the Exhaust Hood Face in the Design of Push–Pull Ventilation. In: Long, S., Dhillon, B. (eds) Man–Machine–Environment System Engineering . MMESE 2019. Lecture Notes in Electrical Engineering, vol 576. Springer, Singapore. https://doi.org/10.1007/978-981-13-8779-1_48
Download citation
DOI: https://doi.org/10.1007/978-981-13-8779-1_48
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-8778-4
Online ISBN: 978-981-13-8779-1
eBook Packages: Intelligent Technologies and RoboticsIntelligent Technologies and Robotics (R0)