Abstract
Diagrid systems have strong structural efficiency than other system like braced system. Diagrid system have unique geometric configuration used for various heights of tall structure. Geometric configurations and grid geometrics of diagrid structure depends on the heights and angle of the diagrids. Joints of diagrid structure are more complicated than conventional structure therefore Construction of diagrid structure is complicated than conventional structure. In early days tall buildings have importance due to its architectural view and diagrid structure have better architectural view as well as good structural stability. In recent forms in tall structure have complex shapes like tapered, twisted and tilted. This paper includes required data, model, Earthquake and Wind analysis of Braced Tube Structure and diagrid structure with Circular, Square and Rectangular plan. Then by keeping same plan area and structural data for circular, square and rectangular plan, Earthquake and Wind analysis result of both Braced Tube and Diagrid Structures is carried out and by comparing the braced tube structures results and diagrid structures results conclusions drawn from the present investigation.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Jani, K., Patel, P.V.: Analysis and design of diagrid structural system for high rise steel buildings. In: Chemical, Civil and Mechanical Engineering Tracks of 3rd Nirma University International Conference on Engineering (NUiCONE 2012), pp. 92–100 (2013)
Panchal, N.B., Patel, V.R., Pandya, I.I.: Optimum angle of diagrid structural system. Int. J. Eng. Tech. Res. (IJETR) 2(6), 150–157 (2014). ISSN 2321-0869
Prashant, T.G., Badami, S.S., Gornale, A.: Comparison of symmetric and asymmetric steel diagrid structures by non-linear static analysis. Int. J. Res. Eng. Technol. (IJRET) 04(05), 486–492 (2015). eISSN 2319-1163, pISSN 2321-7308
Thomas, F.M., Issac, B.M., George, J.: Performance evaluation of tall buildings with steel diagrid system. In: 2nd International Conference on Science, Technology and Management (ICSTM), September 2015, pp. 2242–2256 (2015)
Nimisha, P., Namitha, K.: Structural comparison of diagrid building with tubular building. Int. J. Eng. Res. Technol. (IJERT) 5(04), 57–60 (2016). ISSN 2278-0181
Shah, M.I., Mevada, S.V., Patel, V.B.: Comparative study of diagrid structures with conventional frame structures. Int. J. Eng. Res. Appl. (IJERA) 6(5), 22–29 (2016). ISSN 2248-9622, (Part - 2)
IS 800:2007: Indian Standard Code of Practice for General Construction in Steel, Bureau of Indian Standards, New Delhi
IS 1893:2002 (Part I): Indian Standard Criteria for Earthquake Resistant Design of Structures, Bureau of Indian Standards, New Delhi
IS 875:1987 (Part II): Indian Standard Code of Practice for Design loads (Other than Earthquake) for buildings and structures, Bureau of Indian Standards, New Delhi
IS 875:1987 (Part III): Indian Standard Code of Practice for Design loads (Other than Earthquake) for buildings and structures, Bureau of Indian Standards, New Delhi
Boake, T.M.: Diagrids, the new stability system: combining architecture with engineering. School of Architecture, University of Waterloo, Cambridge, ON, Canada
Moehle, J.P.: Performance-based seismic design of tall buildings in the U.S. In: The 14th World Conference on Earthquake Engineering, Beijing, China, 12–17 October (2008)
Kim, J., Jun, Y., Lee, Y.H.: Seismic performance evaluation of diagrid system buildings. In: 2nd Specialty Conference on Disaster Mitigation, Manitoba, June 2010
Jani, K., Patel, P.V.: Analysis and design of diagrid structural system for high rise steel. In: Chemical, Civil and Mechanical Engineering Tracks of 3rd Nirma University International Conference on Engineering, Procedia Engineering, vol. 51, pp. 92–100 (2013)
Alaghmandan, M., Pehlivan, N.A., Elnimeiri, M.: Architectural and structural development of tall buildings. In: ATINER Conference Paper Series No. ARC 2013: 0758, ISSN 2241-2891, 16 December 2013
Mazinani, I., Jumaat, M.Z., Ismail, Z., Chao, O.Z.: Comparison of shear lag in structural steel building with framed tube and braced tube. Struct. Eng. Mech. 49(3), 297–309 (2014)
Revankar, R.K., Talasadar, R.G.: Pushover analysis of diagrid structure. Int. J. Eng. Innov. Technol. (IJEIT) 4(3), 168–174 (2014). ISSN 2277-3754
Patil, D., Naveena, M.P.: Dynamic analysis of steel tube structure with bracing system. IJRET: Int. J. Res. Eng. Technol. 04(08) (2015)
Chandwani, V., Agrawal, V., Gupta, N.K.: Role of conceptual design in high rise buildings. Int. J. Eng. Res. Appl. (IJERA) 2(4), 556–560 (2012). ISSN 2248-9622
Varsani, H., Pokar, N., Gandhi, D.: Comparative analysis of exo-skeleton, diagrid and conventional structural system for tall building. Int. J. Adv. Res. Eng. Sci. Technol. (IJAREST) 2(3) (2015). ISSN(O) 2393-9877, ISSN(P) 2394-2444
Harsha, S., Raghu, K., Narayana, G.: Analysis of tall buildings for desired angle of diagrids. IJRET: Int. J. Res. Eng. Technol. eISSN 2319-1163, pISSN 23s21-730
Asadi, E., Adeli, H.: Seismic performance factors for low-to mid-rise steel diagrid structural system, 27(15) (2018)
Asadi, E., Li, Y., Heo, Y.A.: Seismic performance assessment and loss estimation of steel diagrid structures. J. Struct. Eng. 144(10) (2018)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Nayak, C., Walke, S., Kokare, S. (2020). Optimal Structural Design of Diagrid Structure for Tall Structure. In: Gunjan, V., Singh, S., Duc-Tan, T., Rincon Aponte, G., Kumar, A. (eds) ICRRM 2019 – System Reliability, Quality Control, Safety, Maintenance and Management. ICRRM 2019. Springer, Singapore. https://doi.org/10.1007/978-981-13-8507-0_39
Download citation
DOI: https://doi.org/10.1007/978-981-13-8507-0_39
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-8506-3
Online ISBN: 978-981-13-8507-0
eBook Packages: EngineeringEngineering (R0)