Abstract
In passive energy dissipation systems used for earthquake resistant structures, base isolation is one of the most powerful systems. For understanding the effect of base isolation system, G + 5 storey models are considered with planner asymmetry. Lead rubber isolator is used for controlling the response of building during earthquake effects and tremors. The paper deals with behavior of fixed base and isolated building in terms of natural time period, top floor acceleration, storey drift, base reaction and energy dissipation. The Non-linear Time history analysis has been performed by using FEM based software SAP2000. The paper also includes the effect of soil structure interaction on both fixed base and isolated base building. It was observed that with use of isolators, time period of structure becomes double as compared with the fixed base model. The soil parameters also plays vital role in performance of isolators.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Ribakov, Y., Iskhakov, I.: Experimental methods for selecting base isolation parameters for public buildings. Open Constr. Build. Technol. J. 2, 1–6 (2008)
Monfared, H., Shirvani, A., Nwaubani, S.: An investigation into the seismic base isolation from practical perspective. Int. J. Civil Struct. Eng. J. 3, 451–463 (2013)
Chandak, N.R.: Effect of base isolation on the response of reinforced concrete building. J. Civil Eng. Res. 3, 135–142 (2013)
Su, L., Ahmadi, G., Tadjbakhsh, I.G.: Performance of sliding resilient-friction base-isolation system. J. Struct. Eng. 117, 165–181 (1991)
Shenton III, H.W., Lin, A.N.: Relative performance of fixed-base and base-isolated concrete frames. J. Struct. Eng. 119, 2952–2968 (1993)
Anilduke, S., Khedikar, A.: Comparison of building for seismic response by using base isolation. Int. J. Res. Eng. Technol. (2015)
Yin, B.: The Effect of Soil Structure Interaction on the Behavior of Base Isolated Structures. Duke University (2014)
Raj, D.: Non-linear Static Analysis of Building-Foundation System considering Soil-Structure Interaction using SAP 2000 v 14. Research Scholar, Department of Earthquake Engineering, IIT Roorkee
Naeim, F., Kelly, J.M.: Design of Seismic Isolated Structures: From Theory to Practice. Wiley, Hoboken (1999)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Jain, M., Sanghai, S.S. (2020). Seismic Response Control of Unsymmetrical RCC Framed Building Using Base Isolation Considering Soil Structure Interaction. In: Gunjan, V., Singh, S., Duc-Tan, T., Rincon Aponte, G., Kumar, A. (eds) ICRRM 2019 – System Reliability, Quality Control, Safety, Maintenance and Management. ICRRM 2019. Springer, Singapore. https://doi.org/10.1007/978-981-13-8507-0_26
Download citation
DOI: https://doi.org/10.1007/978-981-13-8507-0_26
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-8506-3
Online ISBN: 978-981-13-8507-0
eBook Packages: EngineeringEngineering (R0)