Abstract
Influence factors are discussed in detail on the ventilation efficiency of kitchen, including capture efficiency, effect of relevant parameters on hood performance, effect of mannequin, and walk-by motion. Enhanced ventilation systems for kitchen are introduced. Design guidelines are presented.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
ASHRAE Handbook (2009) ASHRAE handbook—Fundamentals. American Society of Heating, Refrigerating, and Air-Conditioning Engineers Inc., Atlanta
ASHRAE Handbook (2011) ASHRAE handbook—HVAC applications. American Society of Heating, Refrigerating, and Air-Conditioning Engineers Inc., Atlanta
Akimoto TAT, Horikawa SHS, Otaka KOK, Hayashi HHH, Lee SLS, Akimoto T (2002a) Research on ventilated ceiling system for commercial kitchen—part 1: computational fluid dynamic analysis and field measurement. In: 8th international conference on air distribution in rooms, ROOMVENT
Akimoto TAT, Horikawa SHS, Otaka KOK, Hayashi HHH, Lee SLS, Akimoto T (2002b) Research on ventilated ceiling system for commercial kitchen—part 2: field measurement of indoor thermal environment and ventilation performance. In: 8th international conference on air distribution in rooms, ROOMVENT
Altamimi NAM, Fadzil SFS, Wan MWH (2011) The effects of orientation, ventilation, and varied wwr on the thermal performance of residential rooms in the tropics. J Sustain Dev 4(2):142–149
Aflaki A, Mahyuddin N, Mahmoud ZA, Baharum MR (2015) A review on natural ventilation applications through building facade components and ventilation openings in tropical climates. Energy Build 101:153–162
ASHRAE 62-1989 (1989) Ventilation for acceptable indoor air quality. American Society of Heating, Refrigerating, and Air-Conditioning Engineers Inc., Atlanta
ASTM F 2474 Standard test for heat load to space performance of commercial kitchen ventilation/appliance systems. United States
ASTM F 1704 (2012) Standard test method for capture and containment performance of commercial kitchen exhaust ventilation systems. United States
Burnett J, Bojić M, Yik F (2005) Wind-induced pressure at external surfaces of a high-rise residential building in hong kong. Build Environ 40(6):765–777
Chandrashekaran (2010) Air flow through louvered openings: effect of louver slats on air movement inside a space. Dissertations and thesis—Gradworks
Chiang CM, Lai CM, Chou PC, Li Y-Y (2000) The influence of an architectural design alternative (transoms) on indoor air environment in conventional kitchens in taiwan. Build Environ 35(7):579–585
Daly BB (1978) Woods practical guide to fan engineering, 3rd edn. Woods of Colchester Limited, Colchester
Debnath R, Bardhan R, Banerjee R (2016) Investigating the age of air in rural indian kitchens for sustainable built-environment design. J Build Eng 7:320–333
DW/171 (1999) Standard for kitchen ventilation systems. Heating and Ventilation Contractors Association, London
Fortmann R (2001) Indoor air quality: residential cooking exposures. ARB Contract Number 97-330, Prepared for California Air Resources Board, Sacramento, California
Farnsworth CA, Waters RM, Fritzsche D (1989) Development of a fully vented gas range. ASHRAE Trans 95(l):759–768
Fugler DW (1989) Canadian research into the installed performance of kitchen exhaust fans. ASHRAE Trans 95(1):753–758
Gao CF, Lee WL (2011) Evaluating the influence of openings configuration on natural ventilation performance of residential units in hong kong. Build Environ 46(4):961–969
GB/T 11228-2008 (2008) Fundamental parameters for kitchens and related equipments in housing. General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China & Standardization Administration, Beijing (in Chinese)
Grieve PW (1989) Measuring ventilation using tracer-gases. Brüel and Kjær, Denmark
Ho UF (1993) Development of the geometric guideline for civil houses in Taiwan. Department of the Interior, Taiwan: Building Research Institute (in Chinese)
Hou XT, Li AG, Wang ZH, Zhao YJ (2011) Numerical study on indoor air quality of commercial kitchen in china. Adv Mater Res 374–377:1100–1105
Huang RF, Dai GZ, Chen JK (2010) Effects of mannequin and walk-by motion on flow and spillage characteristics of wall-mounted and jet-isolated range hoods. Ann Occup Hyg 54(6):625
HVI (2009) HVI loudness testing and rating procedure. HVI Publication 915. Home Ventilating Institute. Wauconda, Illinois
HVI (2010) Certified home ventilating products directory. Home Ventilating Institute, Wauconda, Illinois
Kosonen R (2007) The effect of supply air systems on the efficiency of a ventilated ceiling. Build Environ 42(4):1613–1623
Kosonen R, Mustakallio P (2003) The influence of a capture jet on the efficiency of a ventilated ceiling in a commercial kitchen. Int J Vent 1(3):189–199
Kosonen R, Mustakallio P (2016) Analysis of capture and containment efficiency of a ventilated ceiling. Int J Vent 2(1):33–43
Li AG, Yin HG, Wang GD (2012) Experimental investigation of air distribution in the occupied zones of an air curtain ventilated enclosure. Int J Vent 11(2):171–182
Li A, Yi H, Zhang W (2012b) A novel air distribution method—principles of air curtain ventilation. Int J Vent 10(4):383–390
Li Y, Delsante A (1996) Derivation of capture efficiency of kitchen range hoods in a confined space. Build Environ 31(5):461–468
Lim K, Lee C (2008) A numerical study on the characteristics of flow field, temperature and concentration distribution according to changing the shape of separation plate of kitchen hood system. Energy Build 40(2):175–184
Luo N, Li A, Gao R, Tian Z, Zhang W, Mei S (2013) An experiment and simulation of smoke confinement and exhaust efficiency utilizing a modified opposite double-jet air curtain. Saf Sci 55:17–25
Nagda NL, Koontz MD, Fortmann RC, Billick IH (1989) Prevalence, use, and effectiveness of range-exhaust fans. Environ Int 15(1–6):615–620
Nielsen PV, Allard F, Awbi HB, Davidson L, Schälin A (2007) Computational Fluid Dynamics in Ventilation Design. Vki Adv Des Vent Syst 6(3):291–294
Price PN, Sherman MH (2006) Ventilation behavior and household characteristics in New California Houses. Lawrence Berkeley Nat Lab 3:4
Saha S, Guha A, Roy S (2012) Experimental and computational investigation of indoor air quality inside several community kitchens in a large campus. Build Environ 52(6):177–190
Sandberg M (1981) What is ventilation efficiency. Build Environ 16(2):123–135
Settles GS (2012) Schlieren and shadowgraph techniques: visualizing phenomena in transparent media. Springer Science & Business Media
Shah S, Dufva K (2017) CFD modeling of airflow in a kitchen environment: towards improving energy efficiency in buildings
Singer BC, Delp WW, Apte MG (2011) Experimental evaluation of installed cooking exhaust fan performance. Lawrence Berkeley National Laboratory
Singer BC, Apte MG, Black DR, Hotchi T, Lucas D, Lunden MM, Mirer AG, Spears M, Sullivan DP (2009) Natural gas variability in California: environmental impacts and device performance: experimental evaluation of pollutant emissions from residential appliances
Sobiski P, Swierczyna R, Fisher D (2006) Effects of range top diversity, range accessories, and hood dimensions on commercial kitchen hood performance. ASHRAE Trans 112:603–612
Swierczyna R, Sobiski P, Fisher D (2006) Effects of appliance diversity and position on commercial kitchen hood performance. Ashrae Transactions 112:591–602
Swierczyna R, Sobiski P, Fisher D (2009) Revised heat gain rates from typical commercial cooking appliances from RP-362. ASHRAE Trans 115(2):591–602
Takano S, Yamanaka T, Kotani H et al (2009) Capture efficiency of exhaust hood for commercial kitchen using low radiation cooking equipment with concentrated exhaust. In: The 9th international conference on industrial ventilation, pp 18–21
Veersteg HK, Malalasekera W (1995) An introduction to computational fluid dynamics: the finite volume method. Pearson Schweiz Ag 20(5):400
VDI 2052 (2006) Ventilation equipment for kitchens. Verein Deutcher Ingenieure
Wolbrink DW, Sarnosky JR (1992) Residential kitchen ventilation-a guide for the specifying engineer. ASHRAE Trans 98(l):1187–l198
Zhao YJ, Li AG, Tao PF et al (2013) The impact of various hood shapes, and side panel and exhaust duct arrangements, on the performance of typical Chinese style cooking hoods. Build Simul 6(2):139–149
Zhou B, Chen F, Dong Z, Nielsen PV (2016) Study on pollution control in residential kitchen based on the push-pull ventilation system. Build Environ 107:99–112
Zou SH, Li P, Weng P, Luo YX (2004) Numerical Analysis of the ventilation of a kitchen in residence. Eng Sci 12(6):69–72 (in Chinese)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Copyright information
© 2019 Springer Nature Singapore Pte Ltd.
About this chapter
Cite this chapter
Li, A., Kosonen, R. (2019). High-Performance Kitchen Ventilation. In: Kitchen Pollutants Control and Ventilation. Springer, Singapore. https://doi.org/10.1007/978-981-13-6496-9_7
Download citation
DOI: https://doi.org/10.1007/978-981-13-6496-9_7
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-6495-2
Online ISBN: 978-981-13-6496-9
eBook Packages: EngineeringEngineering (R0)