Abstract
Prior research only explored small-sized window glass with surrounding edges covered by an opaque frame or gasket. Until recently, very little research has been conducted to investigate point-supported glass curtain walls, which are generally supported by four points and widely used as the outside walls of high buildings or separation walls inside buildings. Despite its wide application, its fire resistance and breakage mechanism is not yet well understood, however. If subjected to fire, the entire glass pane would be exposed to strong radiation, and the resulting breaking process would be very different from that of edge-covered glass.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Harada K, Enomoto A, Uede K, Wakamatsu T. An experimental study on glass cracking and fallout by radiant heat exposure. In: An experimental study on glass cracking and fallout by radiant heat exposure. IAFSS, 2000, pp. 1063–74.
Wang Y, Wu Y, Wang Q, Liew KM, Chen H, Sun J, He L. Numerical study on fire response of glass facades in different installation forms. Constr Build Mater. 2014;61:172–80.
Wang Q, Wang Y, Chen H, Xiao H, Sun J, He L. Frame constraint effect on the window glass crack behavior exposed to a fire. Eng Fract Mech. 2013;108:109–19.
Shields J, Silcock GW, Flood F. Behaviour of double glazing in corner fires. Fire Technol. 2005;41:37–65.
Shields TJ, Silcock GWH, Flood MF. Performance of a single glazing assembly exposed to enclosure corner fires of increasing severity. Fire Mater. 2001;25:123–52.
Keskirahkonen O. Breaking of window glass close to fire. Fire Mater. 1988;12:61–9.
Wang Y, Wang Q, Shao G, Chen H, Su Y, Sun J, He L, Wen XJ, Zong R, Liew KM. Experimental study on thermal breakage of four-point fixed glass facade. In: Experimental study on thermal breakage of four-point fixed glass facade. Christchurch, New Zealand, IAFSS, 2014, pp. 666–76.
Wang Y, Wang Q, Shao G, Chen H, Su Y, Sun J, He L, Liew KM. Fracture behavior of a four-point fixed glass curtain wall under fire conditions. Fire Saf J. 2014;67:24–34.
Keski-Rahkonen O. Breaking of window glass close to fire. Fire Mater. 1988;12:61–9.
Chow WK, Gao Y. Thermal stresses on window glasses upon heating. Constr Build Mater. 2008;22:2157–64.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Copyright information
© 2019 Springer Nature Singapore Pte Ltd.
About this chapter
Cite this chapter
Wang, Y. (2019). Breakage of Point Supported Glass Façades in Fire. In: Experimental and Numerical Study of Glass Façade Breakage Behavior under Fire Conditions. Springer Theses. Springer, Singapore. https://doi.org/10.1007/978-981-13-6484-6_4
Download citation
DOI: https://doi.org/10.1007/978-981-13-6484-6_4
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-6483-9
Online ISBN: 978-981-13-6484-6
eBook Packages: EngineeringEngineering (R0)