Abstract
Ahmed glaucoma valve (AGV)TM (New World Medical Inc., CA) is a valved glaucoma drainage device used in the surgical management of glaucoma. Implantation of the device in the pars plana region, into the vitreous cavity, is a viable management option in eyes with glaucoma which have undergone a complete pars plana vitrectomy. The procedure can help in the control of intraocular pressure (IOP) in eyes with several intractable secondary glaucomas, where conventional insertion of the drainage device into the anterior chamber may not be feasible.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Mazinani B, Schwarzer H, Willkomm A, Weinberger A, Plange N, Walter P, Rössler G. Ahmed glaucoma valve via pars plana access. Long-term results of implantation for therapy refractive glaucoma. Ophthalmologe. 2013;110(6):537–42.
Dada T, Bhartiya S, Vanathi M, Panda A. Pars plana Ahmed glaucoma valve implantation with triamcinolone-assisted vitrectomy in refractory glaucomas. Indian J Ophthalmol. 2010;58(5):440–2.
Adachi H, Takahashi H, Shoji T, Okazaki K, Hayashi K, Chihara E. Clinical study of the pars plana Ahmed glaucoma valve implant in refractory glaucoma patients. Nippon Ganka Gakkai Zasshi. 2008;112(6):511–8.
Suárez-Fernández MJ, Gutiérrez-DÃaz E, Julve San MartÃn A, Fernández-Reyes MF, MencÃa-Gutiérrez E. Simultaneous pars plana vitrectomy and glaucoma drainage device implant. Arch Soc Esp Oftalmol. 2010;85(3):97–102.
Lee JY, Sung KR, Tchah HW, Yoon YH, Kim JG, Kim MJ, Kim JY, Yun SC, Lee JY. Clinical outcomes after combined Ahmed glaucoma valve implantation and penetrating keratoplasty or pars plana vitrectomy. Korean J Ophthalmol. 2012;26(6):432–7.
Maris PJ Jr, Tsai JC, Khatib N, Bansal R, Al-Aswad LA. Clinical outcomes of Ahmed Glaucoma valve in posterior segment versus anterior chamber. J Glaucoma. 2013;22(3):183–9.
Diaz-Llopis M, Salom D, GarcÃa-Delpech S, Udaondo P, Millan JM, Arevalo JF. Efficacy and safety of the pars plana clip in the Ahmed valve device inserted via the pars plana in patients with refractory glaucoma. Clin Ophthalmol. 2010;4:411–6.
Wallsh JO, Gallemore RP, Taban M, Hu C, Sharareh B. Pars plana Ahmed valve and vitrectomy in patients with glaucoma associated with posterior segment disease. Retina. 2013;33(10):2059–68.
Seo JW, Lee JY, Nam DH, Lee DY. Comparison of the changes in corneal endothelial cells after pars plana and anterior chamber Ahmed valve implant. J Ophthalmol. 2015;2015:486832.
Parihar JK, Jain VK, Kaushik J, Mishra A. Pars Plana-modified versus conventional Ahmed glaucoma valve in patients undergoing penetrating keratoplasty: a prospective comparative randomized study. Curr Eye Res. 2016:1–7.
Lieberman RA, Maris PJ Jr, Monroe HM, Al-Aswad LA, Bansal R, Lopez R, Florakis GJ. Corneal graft survival and intraocular pressure control in coexisting penetrating keratoplasty and pars plana Ahmed Glaucoma Valves. Cornea. 2012;31(4):350–8.
Faghihi H, Hajizadeh F, Mohammadi SF, Kadkhoda A, Peyman GA, Riazi-Esfahani M. Pars plana Ahmed valve implant and vitrectomy in the management of neovascular glaucoma. Ophthalmic Surg Lasers Imaging. 2007;38(4):292–300.
Wallsh JO, Gallemore RP, Taban M, Hu C, Sharareh B. Pars plana Ahmed valve and vitrectomy in patients with glaucoma associated with posterior segment disease. Retina. 2013;33(10):2059–68.
Ishida K, Ahmed II, Netland PA. Ahmed glaucoma valve surgical outcomes in eyes with and without silicone oil endotamponade. J Glaucoma. 2009;18(4):325–30.
Nazemi PP, Chong LP, Varma R, Burnstine MA. Migration of intraocular silicone oil into the subconjunctival space and orbit through an Ahmed glaucoma valve. Am J Ophthalmol. 2001;132(6):929–31.
Tsui I, Airiani S, Wen A, El-Sawy T, Fine HF, Maris PJ Jr. Intravitreal injection of tissue plasminogen activator as treatment for an occluded pars plana glaucoma tube. Clin Ophthalmol. 2009;3:91–3.. Epub 2009 Jun 2
Odrich S, Wald K, Sperber L. Ab interno management of blocked Ahmed valve in the posterior segment. Glaucoma. 2013;22(5):e9–10.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
7.1 Electronic supplementary material
(MP4 306561 kb)
(MP4 88292 kb)
Rights and permissions
Copyright information
© 2019 Springer Nature Singapore Pte Ltd.
About this chapter
Cite this chapter
Murthy, G.J., Murthy, P.R., Chahar, S. (2019). Pars Plana Ahmed Glaucoma Valve: Surgical Technique. In: Gandhi, M., Bhartiya, S. (eds) Glaucoma Drainage Devices. Springer, Singapore. https://doi.org/10.1007/978-981-13-5773-2_7
Download citation
DOI: https://doi.org/10.1007/978-981-13-5773-2_7
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-5772-5
Online ISBN: 978-981-13-5773-2
eBook Packages: MedicineMedicine (R0)