Skip to main content

AADI Technique

  • Chapter
  • First Online:
Book cover Glaucoma Drainage Devices
  • 481 Accesses

Abstract

Aurolab aqueous drainage implant (AADI) has been marketed in India by Aurolab, Madurai, India, since June 2013. AADI is a non-valved device that is useful in refractory glaucomas when other methods to control the intraocular pressure have failed. It is made of permanent implantable grade silicone, a proven material for patient safety [1]. The implant plate surface area is 350 mm2, and it has lateral wings that are designed to be placed under the rectus muscle. It is a 35 mm silicon tube attached to a 13 mm convex radius plate which conforms to the curvature of the globe. It has additional holes to facilitate anchoring of the end plate to the sclera so as to minimise device movement. There are various surgical methods of implanting a glaucoma drainage device which have been elucidated in this chapter.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 79.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 99.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Gowri Priya C, Sivakumar K, Pillai M, Krishnadas SR, Sriram R, Muthukkaruppan V. Evaluation of surface free energy of Aurolab Aqueous Drainage Implant (AADI) and its influence on cell adhesion property, in comparison with Baerveldt implant. Invest Ophthalmol Vis Sci. 2013;54(15):4475.

    Google Scholar 

  2. Riva I, Roberti G, Oddone F, Konstas AGP, Quaranta L. Ahmed glaucoma valve implant: surgical technique and complications. Clin Ophthalmol. 2017;11:357–67.

    Article  CAS  Google Scholar 

  3. Kansal S, Moster MR, Kim D, Schmidt CM Jr, Wilson RP, Katz LJ. Effectiveness of nonocclusive ligature and fenestration used in Baerveldt aqueous shunts for early postoperative intraocular pressure control. J Glaucoma. 2002;11(1):65–70.

    Article  Google Scholar 

  4. Thakur S, Ichhpujani P, Kumar S. Grafts in glaucoma surgery: a review of the literature. Asia Pac J Ophthalmol (Phila). 2017;6(5):469–76.

    Google Scholar 

  5. Kaushik S, Kataria P, Raj S, Pandav SS, Ram J. Safety and efficacy of a low-cost glaucoma drainage device for refractory childhood glaucoma. Br J Ophthalmol. 2017;101(12):1623–7.

    Article  Google Scholar 

  6. Bayer A, Onol M. Clinical outcomes of Ahmed glaucoma valve in anterior chamber versus ciliary sulcus. Eye (Lond). 2017;31(4):608–14.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

10.1 Electronic supplementary material

Video demonstrating AADI implantation

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Singapore Pte Ltd.

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Kumar, S., Thakur, S. (2019). AADI Technique. In: Gandhi, M., Bhartiya, S. (eds) Glaucoma Drainage Devices. Springer, Singapore. https://doi.org/10.1007/978-981-13-5773-2_10

Download citation

  • DOI: https://doi.org/10.1007/978-981-13-5773-2_10

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-13-5772-5

  • Online ISBN: 978-981-13-5773-2

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics