Abstract
This study aimed to evaluate the clinical efficiency and thermal and microstructural characterization of a silicone gel used as nasal protection in newborns (NB) submitted to non-invasive ventilation (NIV). The study was divided into two stages. In the first, a control case study was performed with 11 NBs hospitalized at the Neonatal Intensive Care Units (NICUs) of a public hospital in the South of Brazil, who required NIV with nasal silicone gel protector. The stage of the injury and the need for replacing the nasal protector were evaluated daily until the suspension of NIV. In the second stage, a sample of silicone gel was aged in the neonatal incubator simulating the conditions of use, it was submitted to thermogravimetric analysis (TGA), X-ray diffraction (XRD) and scanning electron microscopy (SEM), and the results were compared to a sample without aging. The incidence of the injury was 72.72%, being 75% of them of stage I, and 25% of stage II. The mean of detachment during use was 1.5 ± 1,07 times. As for the TGA, the silicone gel presented thermal stability up to 290 °C. Increased crystallinity and presence of microcracks were observed in the sample that had undergone aging. So, we concluded that the silicone gel is a little effective protector in the prevention of nasal injury in NB submitted to NIV.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Oliveira, C.H.T., Moran, C.A.: Estudo descritivo: ventilação mecânica não invasiva em recém-nascidos pré-termo com síndrome do desconforto respiratório. ConScientiae Saúde 8(3), 485–489 (2009)
Nicolau, C.M., Andrade, L.B.: Programa de atualização em Fisioterapia Pediátrica e Neonatal: Cardiorrespiratória e Terapia Intensiva. Artmed/Panamericana, Porto Alegre (2012)
Mahmoud, R.A., Roehr, C.C., Schmalisch, G.: Current methods of non-invasive ventilatory support for neonates. Paediatr. Respir. Rev. 12(3), 196–205 (2011)
Kopelman, B.I., Santos, A.M.N., Goulart, A.L., Almeida, M.F.B., Miyosh, M.H., Guinsburg, R.: Diagnóstico e tratamento em neonatologia. Atheneu, São Paulo (2004)
McCoskey, L.: Nursing care guidelines for prevention of nasal breakdown in neonates receiving nasal CPAP. Adv. Neonatal. Care 8(2), 116–124 (2018)
Xie, L.H.: Hydrocolloid dressing in preventing nasal trauma secondary to nasal continuous positive airway pressure in preterm infants. World J. Emer. Med. 5(3), 218–222 (2014)
Günlemez, A., Isken, T., Gökalp, A.S., Türker, G., Arisoy, E.A.: Effect of silicone gel sheeting in nasal injury associated with nasal CPAP in preterm infants. Indian Pediatr. 47(3), 265–267 (2010)
Radwanski, H.N., Correa, W.E.M., Refosco, T.J., Junior, A., Pitanguy, I.: Silicone gel em cicatrizes de cirurgia plástica: estudo clínico prospectivo. Revista Brasileira de Cirurgia Plástica 25(3), 428–433 (2010)
Borgognoni, L.: Biological effects of silicone gel sheeting. Wound Repair Regen. 10(2), 118–121 (2002)
Fischer, C., Bertelle, V., Hohlfeld, J., Guex, M.F., Dian, C.S., Tolsa, J.F.: Nasal trauma due to continuous positive airway pressure in neonates. Arch. Dis. Child. Fetal Neonatal Edn. 95(6), 447–451 (2010)
Mölnlycke Health Care Homepage. http://mepiform.pt/mepiform/produto/. Accessed 23 Mar 2017
Vasco, M.C., Neto, S.C., Nascimento, E.M., Azevedo, E.: Gamma radiation effect on sisal/ polyurethane composites without coupling agentes. Polímeros 27(2), 165–170 (2017)
Squires, A.J., Hyndman, M.: Prevention of nasal injuries secondary to NCPAP application in the ELBW infant. Neonatal Netw. 28(1), 1–15 (2009)
Boateng, J.S., Matthews, K.H., Stevens, H.N.E., Eccleston, G.M.: Wound healing dressings and drug delivery systems: a review. J. Pharm. Sci. 97(8), 2892–2923 (2008)
Ferrari, F., Bertoni, M., Bonferoni, M.C., Rossi, S., Caramella, C., Waring, M.J.: Comparative evaluation of hydrocolloid dressings by means of water uptake and swelling force measurements: II. Int. J. Pharm. 117(1), 49–55 (1995)
Fernandes, J.D., Machado, M.C.R., Oliveira, Z.N.P.: Prevenção e cuidados com a pele da criança e do recém-nascido. Anais Brasileiros de Dermatologia 86(1), 102–110 (2011)
Haynes, J.S.: Skin integrity and silicone: Appeel® ‘no-sting’ medical adhesive remover. Brit. J. Nurs. 17(12), 1156–1159 (2008)
Sousa, N.F.C., Bonfim, S.F.S.F., Vasconcelos, M.G.L., Bezerra, J.L.O., Silva, D.V.C., Leal, L.P.: Prevalência de lesão do septo nasal em prematuros no uso de prongas nasais. Revista da Escola de Enfermagem da USP 47(6), 1285–1290 (2013)
Camino, G., Lomakin, S.M., Lazzari, M.: Polydimethylsiloxane thermal degradation Part 1. Kinetic aspects. Polymer 42(6), 2395–2402 (2001)
Mano, E.B., Mendes, L.C.: Introdução a polímeros, 2nd edn. Blücher, São Paulo (1999)
Silva, J.D.C.B.K.F.: Avaliação da influência da degradação no comportamento, na estrutura e nas propriedades físicas e mecânicas de implantes mamários de silicone. Tese de Doutorado, Instituto Militar de Engenharia (2014)
Acknowledgements
The authors would like to thank Hospital Waldemar Monastier, the to the Multiuser Material Characterization Center (CMCM), and to the Thermal Analysis and Fuel Spectroscopy and Materials Laboratory of the UTFPR, Medianeira Campus.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Ribeiro, D.F.C., Barros, F.S., Azevedo, E., Fernandes, B.L., Nohama, P. (2019). Clinical and Thermal Evaluation and Microstructural Characterization of Silicone Gel Used in Newborns Submitted to Non-invasive Ventilation. In: Costa-Felix, R., Machado, J., Alvarenga, A. (eds) XXVI Brazilian Congress on Biomedical Engineering. IFMBE Proceedings, vol 70/1. Springer, Singapore. https://doi.org/10.1007/978-981-13-2119-1_12
Download citation
DOI: https://doi.org/10.1007/978-981-13-2119-1_12
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-2118-4
Online ISBN: 978-981-13-2119-1
eBook Packages: EngineeringEngineering (R0)